Dimplex DHWE 100S Скачать руководство пользователя страница 19

www.dimplex.de

2202/B

EN-19

Commissioning

English

5.    Commissioning

NOTE

i

Before connection to the electric network, the do

-

mestic hot water cylinder must be filled with water. 
During the first filling, open the drain valve on the fit

-

ting.

Check the pipelines for leakage and repair leaks if 
necessary.

Check the function of the safety assembly (in the 
closed system).

Carefully open the domestic hot water valve to fill 
the domestic hot water cylinder until the water es

-

capes without bubbles.

Also open and flush the cold water valve.

Switch on the fuse and the fault-current circuit 
breaker.

Set the desired operating mode and temperature, 
see section "6. Operation".

NOTE

i

Water may escape during the heat-up process. Via the 
safety assembly in the closed system, via the fitting 
outlet in the open system.

ATTENTION!

The safety assembly and domestic hot water 

fitting may get hot!

6.    Operation

6.1. Operating elements and display

Fig. 5: Operating elements and display

Brief information on the domestic hot water 

cylinder functions

6.2. Switching the domestic hot water cylinder on 

and off

To switch on the domestic hot water cylinder, press 
the T1 button for at least 3 seconds. Display A1 sig

-

nals the current temperature.
To switch off the domestic hot water cylinder, press 
the T1 button for at least 3 seconds.

6.3. Setting the water temperature

The bar display A1 shows the current water tempera

-

ture (actual temperature).
To change the water temperature, tap on the T1 but

-

ton until the desired temperature is displayed. The de

-

sired temperature (setpoint temperature) is displayed 
for approx. 5 seconds and then saved.
The current water temperature is then displayed per

-

manently.
Adjustable temperatures:

The setting "

e

" is advisable for a domestic hot water 

temperature of approx. 57 °C. The limescale forma

-

tion and heat losses are comparatively low in this 
case.
If the domestic hot water cylinder is not used for an 
extended period, it is advisable to set the control to 
the "frost protection" position. In this setting, the do

-

mestic hot water cylinder keeps the water tempera

-

ture at around 10 °C. This setting prevents the stored 
water from freezing and thus protects the device from 
damage.

Smart Mode

A1

T1

A2
T2

Key

Time

Function

Display A1
(bar)

Display A2
(LED green)

T1

3 sec. Device ON/OFF

Current 
temperature

T1

Short Setting 

Cylinder temperature

Set 
temperature

T2

Short Smart memory

On/off

Lit

Water temperature

Symbol

Bar number

75 °C

III

14

57 °C

e

10

35 °C

I

6

10 °C

2

Содержание DHWE 100S

Страница 1: ...llation and Operating Instructions Deutsch English DHWE 50S DHWE 80S DHWE 100S Instrukcja monta u i u ytkowania Polski Issue 2 Warmwasser Wandspeicher smart Wall mounted water heater smart Na cienny z...

Страница 2: ...DE 2 2202 B www dimplex de Deutsch...

Страница 3: ...ise zum sicheren Betrieb 4 Ger temontage 6 Wasseranschluss 6 Elektrischer Anschluss 8 Inbetriebnahme 9 Betrieb 9 Entleeren des Warmwasserspeichers 10 St rungen 10 Wartung 11 Reinigung 11 Konformit t 1...

Страница 4: ...gen Kinder sollten beaufsichtigt werden um si cherzustellen dass sie nicht mit dem Ger t spielen ACHTUNG In die festverlegte elektrische Installation ist eine Trennvorrichtung nach den Errich tungsbes...

Страница 5: ...3 Aufheizzeit von 10 C auf 65 C 2 kW Minuten 202 233 312 Anschlussgewinde Zu und Ablauf Zoll 1 2 Ablaufstutzen Zoll 3 8 Abmessungen Breite x H he x Tiefe mm 500 x 610 x 512 500 x 830 x 512 500 x 975 x...

Страница 6: ...EIS i Um im Kundendienstfall einen reibungslosen Wech sel des Warmwasserspeichers zu erm glichen sind alle Anschl sse mit l sbaren Verbindungen vorzuse hen 3 1 Wasseranschluss im geschlossenen System...

Страница 7: ...romversorgung ist der Warmwasserspeicher unbedingt mit Wasser zu f llen Wird das im Ger t befindliche Wasser erw rmt so dehnt sich dessen Volumen aus Dies hat zur Folge dass das Auslaufrohr der Armatu...

Страница 8: ...hal ter mit einem Ausl sestrom von INenn 30 mA zu installieren Dem Ger t muss eine Trennvorrichtung mit min destens 3 mm Kontaktabstand vorgeschaltet sein Diese Forderung wird zum Beispiel durch Si ch...

Страница 9: ...zeige A1 signalisiert die aktuelle Temperatur Zum Ausschalten des Warmwasserspeichers dr cken Sie erneut die Taste T1 f r mindestens 3 Sekunden 6 3 Wassertemperatur einstellen Die Balkenanzeige A1 zei...

Страница 10: ...sertemperatur im Speicher w hrend eines Zeitraums von 14 Tagen nicht ber 65 C er w rmt schaltet die vorbeugende thermische Desin fektion den Warmwasserspeicher automatisch auf eine Temperatur von 70 C...

Страница 11: ...ssen Ist der Anoden strom 0 1 mA muss die Schutzanode gewechselt werden Der Fachmann wird nach berpr fung des Warmwas serspeichers auf Grund des festgestellten Zustandes den Zeitpunkt der n chsten Kon...

Страница 12: ...elefonnummer Erzeugnis Nr E Nr siehe Typschild Fertigungsdatum FD siehe Typschild Beanstandung was funktioniert nicht Deutschland Telefon 49 89 69 339 339 Fax 49 89 20 355 199 Mail Ersatzteile sparepa...

Страница 13: ...Notes on safe operation 14 Device Installation 16 Water connection 16 Electrical connection 18 Commissioning 19 Operation 19 Draining the domestic hot water cylinder 20 Faults 20 Maintenance 21 Cleani...

Страница 14: ...supervised to ensure that they do not play with the device ATTENTION A separating device must be installed in the fixed electrical installation in accordance with the setup regulations which has a con...

Страница 15: ...143 Heat up time from 10 C to 65 C 2 kW Minutes 202 233 312 Connection thread inflow and outflow Inch 1 2 Drain nozzle Inch 3 8 Dimensions width x height x depth mm 500 x 610 x 512 500 x 830 x 512 50...

Страница 16: ...ential damage can therefore be avoided NOTE i In order to enable problem free replacement of the domestic hot water cylinder in the event of after sales service work all connections must be detachable...

Страница 17: ...ic hot water cylinder must be filled with wa ter If the water in the device is heated its volume ex pands This means that the drain pipe of the fitting starts to drip This behaviour is related to the...

Страница 18: ...with a trip current of Irat 30 mA must be installed in the electric circuit There must be a disconnecting device upstream of the device with a distance of at least 3 mm This requirement is met via cir...

Страница 19: ...s the T1 button for at least 3 seconds Display A1 sig nals the current temperature To switch off the domestic hot water cylinder press the T1 button for at least 3 seconds 6 3 Setting the water temper...

Страница 20: ...a period of 14 days the preventative thermal disinfection switches the domestic hot water cylinder automatically to a temperature of 70 C This temperature is maintained for 120 minutes 7 Draining the...

Страница 21: ...nt is 0 1 mA the protection anode must be replaced After checking the domestic hot water cylinder the specialist will set the time for the next inspection based on the assessed condition 10 Cleaning S...

Страница 22: ...PL 22 2202 B www dimplex de Polski...

Страница 23: ...dotycz ce bezpiecznej eksploatacji 24 Monta urz dzenia 26 Przy cze wody 26 Przy cze elektryczne 28 Uruchomienie 29 Eksploatacja 29 Opr nianie zbiornika ciep ej wody u ytkowej 30 Usterki 30 Konserwacj...

Страница 24: ...e mog zaj mowa si dzieci pozostawione bez nadzoru Nale y zapewni odpowiedni nadz r nad dzie mi aby wykluczy mo liwo zabawy urz dzeniem UWAGA W zainstalowanej na sta e instalacji elek trycznej musi by...

Страница 25: ...143 Czas nagrzewania od 10 C do 65 C 2 kW minuty 202 233 312 Gwint przy czeniowy wlotu i wylotu cal 1 2 Kr ciec odp ywu cal 3 8 Wymiary szeroko wysoko g boko mm 500 610 512 500 830 512 500 975 512 Mas...

Страница 26: ...wienia bezproblemowej wymiany zbior nika ciep ej wody u ytkowej w razie konieczno ci wy konania us ugi przez serwis posprzeda owy wszyst kie przy cza musz by wyposa one w z cza roz czne 3 1 Przy cze w...

Страница 27: ...ciep ej wody u ytkowej musi by nape niony wod Podczas podgrzewania wzrasta obj to wody w urz dzeniu Wskutek tego zaczyna kapa woda z rury odp ywowej armatury Jest to wynikiem dzia ania urz dzenia Mocn...

Страница 28: ...r dowy o pr dzie wyzwalaj cym Iznam 30 mA Przed urz dzeniem musi by umieszczony roz cznik z odst pem mi dzy stykami co najmniej 3 mm To wymaganie spe niaj na przyk ad bez pieczniki samoczynne W przypa...

Страница 29: ...zycisk T1 przez co najmniej 3 sekundy Wska zanie A1 pokazuje aktualn temperatur Aby wy czy zbiornik ciep ej wody u ytkowej po nownie naciska przycisk T1 przez co najmniej 3 sekundy 6 3 Ustawianie temp...

Страница 30: ...4 dni zapobiegawcza dezynfekcja termiczna automatycznie prze cza zbiornik ciep ej wody u ytkowej na temperatur 70 C Temperatura ta jest utrzymywana przez 120 minut 7 Opr nianie zbiornika ciep ej wody...

Страница 31: ...i anod ochronn Po sprawdzeniu zbiornika ciep ej wody u ytkowej specjalista na podstawie stwierdzonego stanu okre li termin kolejnej kontroli 10 Czyszczenie Do czyszczenia urz dzenie musi by wy czone Z...

Страница 32: ...2202 B www dimplex de Glen Dimplex Deutschland GmbH Telefon 49 9221 709 700 Am Goldenen Feld 18 Telefax 49 9221 709 701 95326 Kulmbach E Mail elektroheizung dimplex de...

Отзывы: