Installation

WINDOW KIT INSTALLATION

Step two:

 Install the exhaust hose assembly to the unit

Push the Exhaust hose into the air outlet opening of the unit along the arrow 
direction.

Step three: 

Preparing the adjustable window slider

1. Choose the window sliders according the size of your window. If the sliders need to 
be cut to meet the window size, please take extra care to cut it properly.
2. Use bolts to fasten the window sliders once they are adjusted to the correct length.

Window slider A

Window slider B

Bolt

Window slider C

Window slider A

Window slider B

Bolts

MODEL A

or

17

Содержание DCP7W

Страница 1: ...For domestic household use only INSTRUCTION MANUAL Portable Air Conditioner Model DCP7W...

Страница 2: ...ter leakage Ensure that the unit is kept upright at all times Do not place on soft unstable or non horizontal angled surfaces Never operate the appliance if a cable or connector has been damaged after...

Страница 3: ...interference Keep the unit at least 1 metre away from electrical appliances such as televisions radios The air conditioner must always be stored and transported upright In case of doubt we suggest you...

Страница 4: ...formation presented on the appliance Do not use means to accelerate the defrosting process or to clean other than those recommended by the manufacturer The appliance shall NOT be stored in a room with...

Страница 5: ...performed General work area All maintenance staff and others working in the local area shall be instructed on the nature of work being carried out Work in confined spaces shall be avoided The area aro...

Страница 6: ...to avoid possibility of sparking That there no live electrical components and wiring are exposed while charging recovering or purging the system That there is continuity of earth bonding Repairs to se...

Страница 7: ...ant circuit to make repairs or for any other purpose conventional procedures shall be used However it is important that best practice is followed since flammability is a consideration The following pr...

Страница 8: ...nt stating the equipment contains flammable refrigerant Recovery When removing refrigerant from a system either for servicing or decommissioning it is recommended good practice that all refrigerants a...

Страница 9: ...tension lead may become overloaded Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there...

Страница 10: ...Minimum Lo 51dB A Noise Level Maximum Hi 62dB A Air Volume Lo Hi 211 272 Refrigerant R290 Fan speeds 2 Modes Cool Fan Dry Timer 24 hours Dimensions w x d x h 329 x 318 x 634mm Min room size 8m2 Max ro...

Страница 11: ...er 9 Upper air intake 10 Drain outlet 11 Air outlet 12 Lower air intake 13 Bottom tray drain outlet 1 2 3 4 5 6 7 8 9 10 11 12 13 front rear Note All the illustrations in the manual are for explanatio...

Страница 12: ...se and increase buttons Used to adjust increasing decreasing temperature settings in 1 C 2 F or 1 F increments in a range of 17 C 62 F to 30 C 88 F or 86 F NOTE The control is capable of displaying te...

Страница 13: ...nit if the malfunction is still present turn off the unit and unplug the power cord Contact the manufacturer or its service agents or a similar qualified person for service Remote Control I SENSE 1 3...

Страница 14: ...NO display High speed Medium speed some units Low speed Auto fan speed AUTO COOL HIGH MED LOW DRY HEAT AUTO HEAT COOL FAN DRY Mode display Fan speed indication FAN HIGH MED LOW Displayed when TIMER ON...

Страница 15: ...t you install your unit on an even surface to minimize noise and vibration The unit must be installed near a sufficient power outlet and if using a continuous drainage method then the plug areas shoul...

Страница 16: ...daptor and unit adaptor clamp automatically by the elastic buckles of the adaptors Unit adaptor Window slider adaptor Exhaust hos e Exhaust hose assembly Type window installation Model A Model B Windo...

Страница 17: ...e Preparing the adjustable window slider 1 Choose the window sliders according the size of your window If the sliders need to be cut to meet the window size please take extra care to cut it properly 2...

Страница 18: ...W KIT INSTALLATION MODEL B Bolt 1 2 1 2 3 Bolt Bolt 1 2 3 4 Bolt Bolt Bolt Bolt 1 4 Window Slider s After assembl y Before assembl y MODEL C Bolt Bolt 1 2 1 2 3 Bolt Window Slider s After assembl y Be...

Страница 19: ...o the window opening between the glass and the window frame to prevent air and insects from getting into the room 3 Cut the non adhesive foam seal C strip to match the width or height of the window In...

Страница 20: ...NOTE Cover the hole using the adaptor cap when not in use Wall Exhaust Expansion anchor positio n Adaptor B Adaptor cap Note To ensure proper function DO NOT overextend or bend the hose Make sure that...

Страница 21: ...d Buckle O N O F F T E M P S H CO U R TT T O I M NE R T O I M FE FR M O D E FA N S LE E P S W I N G LE D 1 set 1 pc Window Slider B Remote Controller and Battery only for remote control models 1 pc Wa...

Страница 22: ...eed Note Under AUTO mode both the AUTO mode and the actual operation mode indicator lights illuminate for some models HEAT operation cooling only models without Press the MODE button until the HEAT in...

Страница 23: ...mode and the unit will continue to operate as originally programmed Note This feature is unavailabe under FAN or DRY mode FOLLOW ME TEMP SENSING feature on some models This feature can ONLY be activa...

Страница 24: ...ure the unit will automatically quit the power management feature The compressor and or fan motor will run Water Drainage Remove the drain plug Continuous drain hose Note Make sure the hose is secure...

Страница 25: ...s will immediately stop However the fan motor will continue to operate this is normal Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Reinstall th...

Страница 26: ...timal performance The water collection tray should be drained immediately after P1 error occurs and before storage to prevent mould In households with animals you will have to periodically wipe down t...

Страница 27: ...e Ask for advice by calling your local after sales service agent or the Customer Care Centre on 1300 556 816 AU 0800 666 2824 NZ Maintenance Recycling Do not dispose of electrical appliances as unsort...

Страница 28: ...com au Supplied by Glen Dimplex Australia 8 Lakeview Drive Scoresby Victoria 3179 Glen Dimplex Australia All rights reserved Material contained in this publication may not be reproduced in whole or i...

Отзывы: