Functions

TIMER

The 

TIMER

 can be set in 1 hour increments up to the maximum timer of 9 hours. The 

set time will be indicated on the display panel and the time indicator turns on and 
the display panel flashes to display the set time, indicating that it is in the timer  
setting state. At this moment, you can press the timer button to set the time, and 
press any key (except the switch key) or wait 5 seconds to exit the setting. After 
setting the timer, the display panel alternately displays the set timer and current 
wind speed at 10 second intervals, and the wind speed indicator and time indicator 
display correspondingly. When the internal timing program reaches the set time, the 
machine will shut down and stay in standby state.

MODE

The default mode after turning “On” is normal. Press this button to select modes 
in this sequence: normal > natural > sleep. The 

MODE

 indicator light will illuminate 

accordingly. There is no indicator for the normal wind mode.

Normal

: The fan runs at a fixed speed for the wind speed selected, without any 

change.

Natural

: The fan motor runs irregularly according to the preset program, and can be 

set to low, medium and high natural wind in conjunction with the wind speed key.
Natural wind is to imitate the effect of natural wind, making the air volume softer 
and more comfortable. 

Sleep

: In natural sleep mode, the wind speed changes with a 30-minute cycle 

change, but does not indicate with the change of natural wind. The fan motor 
performs timing downshifting operation mode according to the wind speed set by 
the user and preset rule of the program. This mode prevents physical discomfort 
due to excessive wind when people fall asleep.
 

High

: 30 minutes high speed natural wind > 30 minutes medium level normal  

 

wind > 30 minutes low level normal wind (until turned off).

 

Medium

: 30 minutes medium level normal wind > low level normal wind (until  

 

turned off).

 

Low

: Low level normal wind (until turned off)..

COOLER / HUMIDIFIER

Press this button once to turn on the 

COOLER / HUMIDIFIER

 function, the pump 

will start and the 

COOLER / HUMIDIFIER

 LED will illuminate. Press this button again 

to turn off the cooling function, and to use as a fan only.

9

Содержание DCEVP8BW

Страница 1: ...For domestic household use only INSTRUCTION MANUAL 8L Evaporative Cooler Model DCEVP8BW...

Страница 2: ...he product Improper repair may cause danger to users Disconnect the appliance from mains power whenever it is not in use before relocating it filling it and before cleaning Operate the appliance only...

Страница 3: ...ake the plug out of the socket If you are not using the unit Before you clean or carry out maintenance on the unit If a fault occurs During filling In the event of an electrical storm Avoid electromag...

Страница 4: ...tension lead may become overloaded Where there is risk of fire or close to a naked flame Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals If there...

Страница 5: ...o air speed 7m s Water tank capacity 8L Remote control Y Timer 0 9 hours Swing function Y Controls Button with LED display Max room size 20m2 Water consumption 1L h high speed Weight net 7kg Dimension...

Страница 6: ...s Ice pack x 2 Remote 1 Top panel 2 Rear panel 3 Front panel 4 Base 5 Display 6 Vertical blade 7 Horizontal blade 8 Remote control storage 9 Rear screen 10 Cord winding frame 11 Water tank 12 Power co...

Страница 7: ...Display Control Panels Control Panel Display Panel On Off Swing Fan speed Wind Mode Cooler Humidifier Timer On Off Swing Cooler Humidifier Wind Mode Timer Fan speed 7...

Страница 8: ...timer setting If the sleep wind mode was on before turning off the mode will not be memorized after turning it on again but the normal wind mode will start To turn the unit OFF press this button again...

Страница 9: ...t a fixed speed for the wind speed selected without any change Natural The fan motor runs irregularly according to the preset program and can be set to low medium and high natural wind in conjunction...

Страница 10: ...rotection function When the cooling function is first turned on the water pump works for 50 seconds If low water is detected the pump will stop working and a buzzer alarm beeps 10 times Uninterrupted...

Страница 11: ...settings 9 Press the SWING function as required 10 To switch the unit off at any time press the ON OFF button Precautions Do not overfill the water tank check the MAX fill line Only fill the water ta...

Страница 12: ...ompletely remove the water tank from the unit by rotating the Cord winding frame clips 90 and removing the water tank by putting your hand into the water tank rotate the fixing buckle 90 and then push...

Страница 13: ...ground water polluting the food chain and damaging health and well being Warranty Please refer to the warranty card in the box for warranty information For any troubleshooting advice please contact th...

Страница 14: ...14...

Страница 15: ...15...

Страница 16: ...Supplied by Glen Dimplex Australia 8 Lakeview Drive Scoresby Victoria 3179 Glen Dimplex Australia All rights reserved Material contained in this publication may not be reproduced in whole or in part...

Отзывы: