Important Safeguards  

• 

Read all instructions.  

• 

Disconnect the power plug before dismantling, assembling or before cleaning.  

• 

Avoid touching mobile parts of the appliance.  

• 

Never insert fingers, pencils or any other objects though the guards whenever the power plug is 
connected, especially while running.  

• 

The appliance is not intended for use by young children or infirm persons unless they have been 
adequately supervised by a responsible person to ensure that they can use the unit safely.  

• 

Young children should be supervised to ensure that they do not play with the appliance.  

• 

Do not use the appliance for any other purpose than its intended use.  

• 

The appliance must not be used if the guards are not fastened according to instructions.  

• 

When the power cord is damaged, it must be replaced by the manufacturer or its service agent 
or a similarly qualified person in order to avoid a hazard.  

• 

Do not use your appliance with an extension cord unless it has been checked and tested by a 
qualified electrician or electrical supplier.  

• 

Return to Hagemeyer or authorised service agent.  

• 

The air conditioning unit must always be stored and transported upright, otherwise you 
may cause irreparable damage to the compressor; in case of doubt we suggest to wait for 
at least 24 hours before you start the air-conditioning unit. 

 

• 

Avoid restarting the air conditioning unit unless 4 minutes have passed since being turned off, or 
the compressor may get damaged.  

• 

Never use the mains plug as a switch to start and turn off the air conditioning unit. Use the 
provided ON/OFF switch located on the control panel.  

• 

Always place the portable air conditioner on a dry stable surface. 

 

Energy Saving Tips 

• 

Do not cover or restrict the airflow from the Outlet or Inlet grills.  

• 

The minimum distance from furniture and wall should be 50cm.  

• 

Keep blinds and /or draperies, on any windows, closed during the sunniest part of the day.  

• 

Keep the filters clean. Under normal conditions, the filters should be cleaned approximately 
every 30 days. Since the filters remove airborne particles, more frequent cleaning maybe 
necessary, depending on the indoor air quality.  

• 

Set the fan speed switch to high cool and the thermostat to the coolest position for the initial 
start-up, then set the Fan switch to Low cool and lower the thermostat to a comfortable setting.  

 

Содержание DAC12AC

Страница 1: ...PORTABLE AIR CONDITIONER Model DAC12AC Please read and retain this manual for future reference ...

Страница 2: ...and the highest performance in the safest possible conditions is to be obtained We suggest that you read the manual carefully before installing or starting up the appliance The air conditioning unit is of the mono tube type transferable on wheels with air air operating system for domestic use and has 3 settings Ventilate Cool Dehumidify The ventilation mode moves the air allowing for its recycling...

Страница 3: ...ised service agent The air conditioning unit must always be stored and transported upright otherwise you may cause irreparable damage to the compressor in case of doubt we suggest to wait for at least 24 hours before you start the air conditioning unit Avoid restarting the air conditioning unit unless 4 minutes have passed since being turned off or the compressor may get damaged Never use the main...

Страница 4: ... running costs Low noise and strong breeze 4 On off timer function Three minute restart delay to protect compressor Part Names 1 Control panel 2 Air outlet grille 3 Remote control sensor 4 Adjustable air flow 5 Transport handle 6 Castors 7 Evaporator air inlet 8 Water draining hole for continuous drainage 9 Power cord 10 Water drainage hole for emptying the water tank when full Accessories ...

Страница 5: ...o use your portable air conditioner Fig 1 Fig 2 Fig 3 Fig 4 5 Permanent installation Fig 5 Fix the exhaust hose adapter to the exhaust terminal of the unit and screw in the exhaust hose Make a round hole with the diameter more than 120mm then input and fix the window kit adaptor Fit the supplied round adapter on the air outlet duct then connect it with the Cover Fig 5 Incorrect mounting Fig 6 Fig ...

Страница 6: ...e room temperature or time when in Time On Off mode 6 LCD DISPLAY Displays the different signals accordingly NOTE To change from Fahrenheit to Celsius press both UP and DOWN buttons at the same time Remote control 1 High fan speed button 2 Medium fan speed button 3 Low fan speed button 4 Swing button 5 Timer button 6 Up button to set temperature and time 7 Down button to set temperature and time 8...

Страница 7: ... Dry mode cannot be used to cool the room Fan Mode Press MODE button Fan on remote to choose Fan mode The LCD will display Press SPEED button Low Med High on remote to select the fan speed The LCD will display accordingly Press SWING button to make the fins swing for oscillation available on the remote control only The LCD will display The temperature cannot be set Do not use the air outlet duct T...

Страница 8: ...power supply Important It is recommended that you do not move the unit around without firstly draining the internal tank If water is left in the unit then it may spill out onto the floor or carpet Maintenance Cleaning Turn off the unit and pull the plug out of the socket before cleaning 1 Clean the surface Clean the surface of the unit with a duster or a damp soft cloth Do not use chemical solvent...

Страница 9: ...if possible Dirty filter Clean or replace the air filter s Air inlet or air outlet is blocked Remove the blockage The unit does not seem to perform Room temperature is lower than then selected value Change temperature selection The unit is noisy The unit is not on flat surface Place the unit on an even solid surface less vibrations The compressor does not work The overheat protection is probably a...

Страница 10: ... any difficulties with your appliance you should firstly contact Dimplex Customer Care for advice Please retain your receipt as proof of purchase Every request for guarantee service must be accompanied by proof of purchase For any information on your Dimplex product please call our Customer Care line 1300 739 033 Be sure to attach your proof of purchase to this card and present with the appliance ...

Отзывы: