CXLN Storage heater section - Principle of operation

The storage heater section of the CXLN heater consists of a core of 

high density heat storage bricks surrounded by a carefully designed 
insulating case.  During the night time off-peak period elements within 
the brick core heat up the bricks to a temperature level determined 
by the setting you select using the input control knob.

In the morning, when the core is at its hottest, the amount of heat being 

transmitted through the insulation and emitted as radiant heat is at its 
greatest and the heater feels hot over most of its upper outer surfaces. 

Diagram 2.

As the day progresses, heat is transmitted from the heater to the room 

and the outer surface of the heater becomes less hot and the amount of 
heat released in this way becomes less.

If the amount of emitted heat becomes insuf

fi

 cient the output of the 

heater and thus the room temperature may be increased by means of 
the Output Control.  This control operates a damper 

fl

 ap within the heater 

which, when the output control knob is at minimum, covers vertical airways 
which pass directly through the centre of the core of the heater.  Even 
when the outer surfaces of the heater are noticeably less hot, the core of 
bricks can still be at a relatively high temperature.  Opening the damper 

fl

 ap by moving the output control away from minimum allows the room 

air to circulate through this hot core and release more heat to the room 
by convection. 

Diagram 3.

Input Control

The setting of this control determines the amount of charge taken in by the heater, which in turn determines the temperature of the 

heater’s storage core.  The higher the charge taken the higher the core temperature.

In colder weather the heater should be set to take a high charge, the control being set at maximum ensures the heater accepts a full 

charge.

In the Autumn and Spring a lower setting of the input control knob should be suf

fi

 cient, the actual setting required being in

fl

 uenced by 

the prevailing weather conditions, the room size and insulation levels.  The most suitable settings will be found by experience.

Output Control

Depending upon the amount of charge accepted by the heater, the OUTPUT control allows the release of additional heat by means of 

a damper which can be opened to allow a greater air 

fl

 ow through the heater core, and therefore additional circulation of heat.  By altering 

the setting of the Output control knob the damper may be opened and closed manually, or it may be made to open automatically.

Manual Operation

With the OUTPUT control on minimum the damper remains closed, and heat is released from the heater only by normal radiation and 

convection around the outer surfaces of the heater.  This alone may provide suf

fi

 cient heat on many occasions and therefore no alteration 

of the OUTPUT control is necessary.  However, if a boost of heat is required in the evening period, then moving the OUTPUT control 
to maximum in the evening will immediately open the damper to allow more rapid release of any available stored heat.  When the next 
charging period commences the damper will automatically close to prevent this release of extra heat during the charge period, but the 
OUTPUT control must be returned to minimum manually to obtain a similar operation the following day.