Dimplex Copenhagen COP20 Скачать руководство пользователя страница 4

Installation

 

- see 

Fig. 1 & 3.

Your electric fire is designed to be used in a fireplace opening or placed 

against a wall anywhere in the room.

When  installing  this  appliance  in  an  existing  fireplace  opening,  we 

recommend that an open chimney or flue is blocked off. We recommend 

that non-flammable materials are used to block off the chimney flue. This 

procedure is important for the efficient operation of the heating unit and 

will also reduce heat loss up the chimney.

At the rear of the fire, two adjustable feet are provided for levelling the 

fire  where  the  fire  is  being  installed  on  an  uneven  surface. You  can 

adjust the foot by removing the two screws and refitting the foot in the 

required position.

The fire is supplied with screws and rawl plugs to provide extra stability 

to prevent it from accidentally being knocked over. The rawl plug supplied 

is suitable for use in block walls (other wall types may need alternative 

rawl plugs). 

To place the appliance flush to a wall please follow these instructions:

Drill holes using a 6mm drill as illustrated in Fig.1. Insert plugs and screws. 

The plug supplied is suitable for use in block walls (special fasteners 

are required on stud walls). Do not fully tighten screws, leave the head 

of the screw at least 10mm away from the surface. Place the keyhole 

slots on the fire over the screws and lower into position.
To gain access to the fixing holes in the base, remove the fret and fuel 

effect from the fire. Remove the fret by lifting it up and then pulling it out 

from the fire, remove the 3 screws holding the fuel bed in place and slide 

it away from the fire.(See Fig. 3, shown Kansas Fret). Using the screws 

provide screw the fire in place as shown in Fig. 1. Carefully refit the fret 

and fuel effect in reverse of the removal procedure as described above.
The other models fret removes in the same manner as the Kansas fret.

Manual Controls 

- see 

Fig. 2

Three switches provide a choice of heat setting. Each switch is activated 

when the bottom half of the switch is pushed in.

Switch 1

 Controls the electricity supply to the heater.

 

Note: This switch must be in the ON position for the heater

 

 to operate with or without heat.

Switch 2 

Provides 950 W heat output. 

Switch 3 

Provides 1900 W output when used in conjunction with switch2

Thermostat 

In order to maintain a certain room temperature, set the thermostat 

knob to ‘max.’. Operate the appliance at full power until the required 

room temperature is reached. Turn back the thermostat knob until the 

appliance switches off. This temperature will be kept almost constant by 

the thermostat switching on and off automatically.Please note that the 

appliance will only operate when the thermostat setting is higher then 

the room temperature.

Thermal Safety Cut-out

A thermal safety cut-out is incorporated in the heater to prevent damage 

due to overheating. This can happen if the heat outlet was restricted 

in any way. The heater will switch on once the obstruction has been 

removed and the heater has cooled. If the cut-out continues to operate 

intermittently, the heater should be switched off and a service agent 

contacted.

IMPORTANT: THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE

UK

Dimplex

Millbrook House

GrangeDrive

HedgeEnd

Southampton

Hampshire.SO30 2DF

TEL: 0844 879 3588

FAX: 0844 879 3583

WEBSITE: www.dimplex.co.uk
Republic of Ireland          

Tel.01 8424833

[c] GDC Group Ltd,

All rights reserved. Material contained in this publication may not be reproduced in whole or in part, without prior permission in writing of Dimplex.
A division of GDC Group Ltd, 

Dakota / Kansas / Inver / Copenhagen 
Model: DKT20 / KNS20 / INV20 / COP20

Maintenance

WARNING: ALWAYS DISCONNECT FROM THE POWER SUPPLY 

BEFORE ATTEMPTING ANY MAINTENANCE.

Light Emitting Diode

This  fire  is  fitted  with  LED  (Light  Emitting  Diode)  lamps  in  place  of 

conventional bulbs . These generate the same light levels as conventional 

bulbs, but use a fraction of the energy consumed. These LED lamps 

are maintenance – free and should not require replacing during the life 

of the product.

Cleaning 

WARNING – ALWAYS DISCONNECT FROM THE POWER SUPPLY 

BEFORE CLEANING THE HEATER.

For general cleaning use a soft clean duster – never use abrasive 

cleaners. The glass viewing screen should be cleaned carefully with a 

soft cloth. DO NOT use proprietary glass cleaners.

To remove any accumulation of dust or fluff the soft brush attachment of 

a vacuum cleaner should occasionally be used to clean the outlet grille 

of the fan heater.

Recycling

For electrical products sold within the European 

Community.

At the end of the electrical products useful life it should 

not be disposed of with household waste. Please 

recycle where facilities exist. Check with your Local 

Authority or retailer for recycling advice in your country.

After Sales Service

Your product is guaranteed for one year from the date of purchase.

Within this period, we undertake to repair or exchange this product free 

of charge (excluding lamps & subject to availability) provided it has been 

installed and operated in accordance with these instructions. 

Your rights under this guarantee are additional to your statutory rights, 

which in turn are not affected by this guarantee.

Should you require after sales information or assistance with this product 
please go to 

www.dimplex.co.uk 

where you will find our self help guide 

by clicking on “After Sales” or ring our helpdesk on 0844 879 3588 (UK) 

or 01 842 4833 (R.O.I.)  .
Spare parts are also available on the website 

www.dimplex.co.uk

Please retain your receipt as proof of purchase.

Отзывы: