background image

Wiring Diagrams

CFS30 - see Fig. 7.

CFS60, CFS90 & CFS120 - see Fig. 9.

A - Heat 1 Contactor
B - Heat 2 Contactor
C - Cut-out circuit
D - Mains In Terminal Block
E - Elements
T - Control Terminal Block
M - Motor

Switch Panel

Installation

The backing box should be fixed to a suitable wall with
appropriate conduit used where applicable to carry the cable
between the heater and the switch panel. (see 

Fig. 8

 for

dimensions)
This cable used to connect the heater to the switch panel should
have sufficient cores (typically 5 core) to allow connection as per
the enclosed wiring diagram and be at least 1.0mm².
Test all switch settings once installation is complete.

Switch Panel Connections

Connections are made as shown in 

Fig. 10

. (References listed

below).

1

- FAN ON - OFF

2

- HEAT 1

3

- HEAT 2

T

- TERMINAL BLOCK

SPC - SWITCH PANEL CABLE TO HEATER (NOT SUPPLIED)

Tip: When stripping back the switch panel cable make note of
the numbering or colours of each wire and their associated
connections to the terminal block.

Operation of switch panel

Switch on electrical supply (MAINS IN) to the heater. Switching
the switch marked ‘

I

’ energises the fan. The heat selection

switches allow heat settings to be chosen as shown below:

Settings -

I

Fan Only

I + 

Half Heat

I +    

Full Heat

The desired heater setting can be obtained through switch
selection.

Thermal Safety Cut-out

The power supply to the heating elements will be interrupted if
one or a combination of the following abnormal events occurs:

1.

Air inlet or outlet grilles are obstructed.

2.

Internal ventilation is impaired due to build up of dust and
fluff.

3.

Blower unit stalls.

NOTE

: Before re-setting the reason for activation must be

determined and corrective action taken.
To reset the thermal safety cut-out for the CFS60, CFS90 or
CFS120 models, access reset buttons as shown in 

Fig. 11

 and

push in direction of arrow. The CFS30 has an electrical reset
cut-out which requires the power supply to be removed for a
short period of time to allow the cut-out cool down. On return of
the power supply, the heater should operate normally.

Recycling

For electrical products sold within the
European Community.
At the end of the electrical products useful life it
should not be disposed of with household
waste. Please recycle where facilities exist.
Check with your Local Authority or retailer for
recycling advice in your country.

Cleaning

WARNING: DISCONNECT SUPPLY before carrying out
maintenance.

External appearance can be maintained by wiping occasionally
with a damp cloth. For stain removal, a weak soap solution can
be applied with a cloth and the surface wiped dry. Care must be
taken to avoid any moisture ingress into the product.

After Sales Service

Your product is guaranteed for one year from the date of purchase.
Within this period, we undertake to repair or exchange this product
free of charge provided it has been installed and operated in
accordance with these instructions.
Your rights under this guarantee are additional to your statutory
rights, which in turn are not affected by this guarantee.
Should you require after sales service you should contact our
customer services help desk on 0870 727 0101.  It would assist
us if you can quote the model number, series, date of purchase,
and nature of the fault at the time of your call.  The customer
services help desk will also be able to advise you should you
need to purchase any spares.
Please do not return a faulty product to us in the first instance as
this may result in loss or damage and delay in providing you with
a satisfactory service.
Please retain your receipt as proof of purchase.

Содержание CFS120

Страница 1: ...r 08 19437 1 UK Issue 1 The product complies with the European Safety Standards EN60335 2 30 and the European Standard Electromagnetic Compatibility EMC EN55014 EN60555 2 and EN60555 3 which cover the essential requirements of EEC Directives 73 23 and 89 336 ...

Страница 2: ...000mm Min 2 3a 1 3b 4 6 5 CFS30 CFS60 CFS90 CFS120 CFS30 7 70mm 70mm 1 2 c d y b a y 2 3 x 1 a b d c CFS60 CFS90 CFS120 D 230 240V 1PN T E L1 F H1 H2 E L N C M E L H D1 D2 CFS30 306 262 495 526 CFS60 386 360 565 630 CFS90 386 360 565 630 CFS120 386 360 565 630 ...

Страница 3: ... CFS90 CFS120 CFS60 CFS90 CFS120 FACTORY SUPPLIED 220 240V 1PN E 380 415V 3PN E 220 240V 3P E L2 L3 N L1 N L1 L2 L3 L2 L3 N L1 CFS90 CFS120 PINK PINK BLUE BLUE BLUE BLUE VIOLET VIOLET BROWN BROWN ORANGE ORANGE WHITE WHITE BROWN BROWN BROWN VIOLET VIOLET BROWN BLUE BLUE BLUE BLUE WHITE WHITE PINK PINK ORANGE ORANGE PINK PINK BLUE BLUE BLUE BLUE VIOLET VIOLET BROWN BROWN BROWN WHITE WHITE ORANGE ORA...

Страница 4: ...t to the wall and assemble the heater to the extension tube using a bolt and wing nut fitted into hole 1 shown in Fig 3a Rotate the heater as shown in Fig 3b and fix the heater into position using the remaining bolt and wing nut in hole 2 Pivot and rotate the heater into the desired position and tighten all three wing nuts A 6mm Allen key can be used as an aid to tightening the bolts Electrical an...

Страница 5: ...To reset the thermal safety cut out for the CFS60 CFS90 or CFS120 models access reset buttons as shown in Fig 11 and push in direction of arrow The CFS30 has an electrical reset cut out which requires the power supply to be removed for a short period of time to allow the cut out cool down On return of the power supply the heater should operate normally Recycling For electrical products sold within...

Страница 6: ......

Страница 7: ......

Страница 8: ...i 8 30AM 1 00PM Sat Customer Services Tel 0870 7270101 Fax 0870 7270102 e mail customer services glendimplex com Republic of Ireland Tel 01 8424833 c Glen Dimplex UK Limited All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of Glen Dimplex UK Limited ...

Отзывы: