THESE INSTRUCTIONS SHOULD BE READ CAREFULLY AND RETAINED FOR FUTURE REFERENCE
Important Safety Advice
DO NOT COVER OR OBSTRUCT the air inlet or outlet grille.
IMPORTANT – Disconnect from the mains supply before
carrying out maintenance work.
THIS APPLIANCE MUST BE EARTHED
This heater must not be located immediately above or below
a fixed socket outlet or connection box.
Keep combustible materials such as drapes and other
furnishings clear from the front, sides and rear of the heater.
The heater should always be used on a flat, stable surface.
DO NOT use this heater in the immediate surrounding of a
bath, a shower or a swimming pool.
DO NOT use this heater in areas where excessive dust exists.
DO NOT store or use any flammable materials or sprays in
the vicinity of the appliance – FIRE HAZARD.
DO NOT insert any foreign objects into the appliance openings.
Risk of injury, electric shock or damage to the appliance may
occur.
DO NOT use the heater on deep pile carpets or the long hair
type of rugs.
DO NOT operate the appliance with wet hands.
DO NOT use heater to dry your laundry.
DO NOT operate the heater with the mains lead overhanging
the front outlet grille.
This appliance is not intended for use by children or other
persons without assistance or supervision if their physical,
sensory or mental capabilities prevent them from using it
safely. Children should be supervised to ensure that they do
not play with the appliance.
The heater carries the Warning symbol
indicating that it
must not be covered.
The socket-outlet must be accessible at all times to enable
the mains plug to be disconnected as quickly as possible.
The instruction leaflet belongs to the appliance and must be
kept in a safe place. If changing owners, the leaflet must be
surrendered to the new owner.
IMPORTANT – If the mains lead of this appliance is damaged,
it must be replaced by the manufacturer or its service agent
or a similarly qualified person in order to avoid a hazard.
Ensure proper manual handling procedures are observed at
all times.
CAUTION – In order to avoid a hazard due to inadvertent
resetting of the thermal cut-out, this appliance MUST NOT be
supplied through an external switching device, such as a
timer, or connected to a circuit that is regularly switched on
and off by the utility.
General
Model
Loading
Current
Voltage
(kW)
(amps)
(volts)
CFP30
3
13
∼
230 - 240
The industrial fan heater is a robust, heavy duty portable appliance. It is
designed for use in garages, workshops and store rooms. A heat selector
switch and thermostat gives a wide range of control.
Some of the appliance’s features are highlighted in
Fig. 1
.
(a)
Robust tubular frame for carrying the heater.
(b)
Thermostat / Heat control housing.
(c)
Metal air outlet grille.
(d)
2m long supply cable with 13amp plug.
(e)
Impact resistant high temperature end mouldings.
Electrical
The supply cable - see (d) in
Fig. 1
(3 x 1.5mm²) is specifically designed
for this appliance. This cable should only be replaced by a similar cable
supplied by the manufacturer.
If using an extension cable, ensure that this complies with local electrical
regulations and is suitable for a 16A load.
See
Fig. 3
for details on Wiring Diagram.
A -
Motor
B -
Thermostat
C -
Thermal Safety Cut-out
D -
Heat/Fan Selection Switch
E -
Heating Elements
F -
Mains Lead & Plug
G -
Earth
Electrical connection
This heater must only be connected to an
A.C.~
supply. The supply
voltage must correspond to the voltage shown on the heaters rating
label. This heater is fitted with a plug incorporating a 13 amp fuse. When
replacing the fuse, a 13 amp fuse approved by ASTA to BS 1362 must be
used.
IMPORTANT :
The wires in this mains lead are coloured in accordance
with the following code :
BROWN :
LIVE
BLUE :
NEUTRAL
GREEN
& YELLOW :
EARTH
As the colours of the wires in the mains lead may not correspond with
the coloured markings in your plug, proceed as follows :
Connect the
BROWN
wire to the terminal marked ‘
L
’ or coloured
RED
.
Connect the
BLUE
wire to the terminal marked ‘
N
’ or coloured
BLACK
.
Note :
‘
L
’ or ‘
N
’ must not be connected to the
EARTH
terminal marked ‘
E
’
or
or coloured
GREEN
or
GREEN AND YELLOW
.
If in doubt, consult your electrician.
Operation
The heat output from this appliance is regulated using the rotating wheels
shown in
Fig. 4
. By rotating these wheels, with the unit plugged in,
various fan and heat setting may be obtained.
Function control wheel
With the function control wheel, (f) in
Fig. 4
, the settings shown below
may be obtained;
0
Off
Fan only
1
Half Heat (1.5 kW) + Fan
2
Full Heat (3 kW) + Fan
Thermostat control wheel
The thermostat control wheel, (g) in
Fig. 4
, will adjust the temperature
cut off point of the appliance.
Low Temperature
High Temperature
Both heat and fan operation can be regulated by the thermostat.
The thermostat, (g) in
Fig. 4
enables a constant local ambient temperature
to be maintained.
Turn the thermostat towards the back of appliance to the maximum
setting and allow the heater to operate until the room temperature has
reached the desired level.
Then turn back the thermostat until it ‘just’ operates. Cycling of the
thermostat will then occur to maintain this ambient temperature.
With the function switch in the
1
or
2
position, the heat is regulated by
the thermostat, whilst the fan continues to operate.
Dimplex Industrial Fan Heater
Models : CFP30