Installation
Surface Mounting (50" Models) continued.
1. Position the fireplace on a wall in the place where it will be mounted (Fig. 6). Use a
spirit level (one is supplied) to ensure that fireplace is level on the wall.
2. Ensuring that at least two key-holes, line up with a wall stud (key-holes are spaced
at 10.2cm centre) (Fig. 6) marked (A), mark the location of four screw locations on
the wall (through key-holes).
3. Remove fireplace from wall and store in a safe place away from traffic.
4. Where marked screw locations do not line up with a wall stud, insert (screw in) one
of the two supplied wall anchors (pre-drill if required). Repeat if only two screws
line up with a wall stud.
5. Screw all four supplied #8, 3.8cm square head mounting screws and washers into
the wall and/or wall anchors leaving 6.5mm of thread.
6. Align chosen key-holes with screws and hang fireplace on the wall. Screw heads and
washers will fit through key-holes and fireplace will slide down into place (screws
will slide into narrow part of key-holes).
7. Tighten all four mounting screws down on fireplace chassis.
8. Screw the two supplied #8 square head screws through two of the permanent
mounting holes (Fig. 6) marked (C) which align with a wall stud.
9. Carefully replace and install partially reflective glass and glass brackets using screws
from step 1.
10.
Refer to Front Glass Installation section for final installation procedures.
Partial Recessed (Not possible on 74" Models)- see Fig. 7 & 8
CAUTION:
Two people may be required for various steps of this procedure.
1. Prepare a wall with a framed opening for the correct model (Fig. 7)
• 34" Models: 77.5cm wide x 42cm high
• 50" Models: 118.1 cm wide x 42cm high
NOTE:
The sizing has allowed for 6.4mm around the fireplace insert for ease of
installation. This fireplace does not require any additional venting.
2. Choose your method of supplying power to the unit:
• Plug in (you may run the power cord out of the framed wall opening to an existing
outlet or install an outlet on a nearby wall stud within the wall).
• Hard wire the fireplace.
WARNING:
Do not attempt to wire your own new outlets or circuits. To reduce the
risk of fire, electric shock or injury to persons, always use a licensed electrician.
WARNING:
Ensure that the circuit on which the fireplace is to be installed has the
power cut off at the service panel until installation is complete.
3. Lift fireplace and insert into opening (Fig. 8).
4. Use spirit level (supplied) to level the fireplace within the framing. Adjust as required.
5. Drive four supplied mounting screws through the four mounting holes located in
each corner of the fireplace chassis, into wall studs (Fig. 8).
6. Refer to Front Glass Installation section for final installation procedures.