GenerAl  WArninGS

Wiring procedures and connections should be in 

• 

accordance with the National Electric Code (NEC & 

CEC) and local codes.

Do not install these heaters against combustible, low 

• 

density cellulose fibre surfaces.

Do not locate these heaters below any electrical conven-

• 

ience receptacles.

Do not store gasoline or flammable solvents in the vicin

-

• 

ity of these heaters.

HigH TEmpERaTuREs

• 

:  Keep electrical cords, furni

-

ture, draperies or any other blocking material away from 

the heater.

recommendations for locating Drapes and Furniture 

near Heaters

For most satisfactory operation of the baseboard heaters and 

minimum effect on drapes and furniture, the following recom

-

mendations should be observed:

Hang drapes so that, in use, they extend below the 

1. 

center line of the heater, but with at least 1.5 inches 

clearance from the finished floor covering (such as car

-

pet, if used).

Hang drapes so that there is at least 3 inches between 

2. 

the extreme front of the heater and the nearest fold of the 

drapes in the folded back (opened drape) position.
Hang drapes so there is at least 1.5 inches between the 

3. 

top of the drapes and the ceiling.
To be suitable for draperies located close to heaters, 

4. 

material should not discolour nor distort dimensionally 

(stretch or shrink) upon extended exposure (1000 hrs.) to 

a temperature of 200º F (93º C).

!

 nOTe: 

If drapes are to be cut off above a heater, they

should be cut off at least 6 inches above the top of the 

heater and preferably more.

!

 nOTe: 

Place furniture no closer then 3 inches from the

 baseboard heater.

 installation instructions

  impOrTAnT inSTrucTiOnS

When using electrical appliances, basic precautions should 

always be followed to reduce the risk of fire, electric shock 

and injury to person, including the following: 

Read all instructions before using this heater.

1. 

a heater has hot and arcing or sparking parts inside.  Do 

2. 

not use it in areas where gasoline, paint or flammable 

liquids are used or stored.
This heater is hot when in use.  To avoid burns, do not let 

3. 

bare skin touch hot surfaces.  If provided, use handles 

when moving this heater.  Keep combustible materials 

such as: furniture, pillows, bedding, papers, clothes and 

curtains away from heater.
To prevent a possible fire, do not block air intakes or 

4. 

exhaust in any manner.  Do not use on soft surfaces like 

a bed where openings may become blocked.

Do not insert or allow foreign objects to enter any venti

-

5. 

lation or exhaust opening as this may cause an electric 

shock or fire, or damage the heater.

SAve THeSe inSTrucTiOnS

Wall installation

Unpack the heater from the carton and lift the front/top 

1. 

panels up & off the heater.

Remove the desired terminal box covers(s) and sup-

2. 

ply wire entry knockouts from the terminal boxes.  (See 

Figure 1 for locations)

!

 nOTe:

 it is only necessary to remove the knockout(s)

that will feed the power supply wiring, keeping in mind 

the heater mounting location and supply wire location in 

the wall.

Determine the correct mounting height and scribe or 

3. 

snap a level line on the wall to maintain each heater back 

plate in a horizontal alignment, when mounting.

!

 nOTe: 

Bottom air inlet heaters must be mounted a 

minimum of 2” from the bottom of the heater to the 

finished floor.

Mount the back plate to the wall using suitable fasteners

 

4. 

(provided by the customer) using the scribed line on the 

wall to keep the heater level.

!

 nOTe: 

Should the wall surface be uneven, secure 

the heater back panel to the high spots.  This will avoid a 

distorted appearance.

proceed to the wiring instructions.

5. 

Floor installation

Unpack the heater and pedestal(s) from the carton( the 

1. 

pedestals are packed at the end of the carton) and lift the 

front/top panels up and off the heater.
Disassemble the pedestal base from the pedestal pad.

2. 

Remove the desired terminal box cover(s) and supply 

3. 

wire entry knockouts from the terminal boxes. (See 

Figure 1)

1.5 in 

(3.81 cm)

min

1.5 in (3.81 cm)

min

1.5 in (3.81 cm)

min

3 in (7.62 cm)

min

3 in (7.62 cm)

min

3 in (7.62 cm)

min

6 in (15.24 cm)

min