7203090000R01
Architectural Heaters
AF6/AS8 Series
GenerAl WArninGS
Wiring procedures and connections should be in
•
accordance with the National Electric Code (NEC &
CEC) and local codes.
Do not install these heaters against combustible, low
•
density cellulose fibre surfaces.
Do not locate these heaters below any electrical conven-
•
ience receptacles.
Do not store gasoline or flammable solvents in the vicin
-
•
ity of these heaters.
HigH TEmpERaTuREs
•
: Keep electrical cords, furni
-
ture, draperies or any other blocking material away from
the heater.
recommendations for locating Drapes and Furniture
near Heaters
For most satisfactory operation of the baseboard heaters and
minimum effect on drapes and furniture, the following recom
-
mendations should be observed:
Hang drapes so that, in use, they extend below the
1.
center line of the heater, but with at least 1.5 inches
clearance from the finished floor covering (such as car
-
pet, if used).
Hang drapes so that there is at least 3 inches between
2.
the extreme front of the heater and the nearest fold of the
drapes in the folded back (opened drape) position.
Hang drapes so there is at least 1.5 inches between the
3.
top of the drapes and the ceiling.
To be suitable for draperies located close to heaters,
4.
material should not discolour nor distort dimensionally
(stretch or shrink) upon extended exposure (1000 hrs.) to
a temperature of 200º F (93º C).
!
nOTe:
If drapes are to be cut off above a heater, they
should be cut off at least 6 inches above the top of the
heater and preferably more.
!
nOTe:
Place furniture no closer then 3 inches from the
baseboard heater.
installation instructions
impOrTAnT inSTrucTiOnS
When using electrical appliances, basic precautions should
always be followed to reduce the risk of fire, electric shock
and injury to person, including the following:
Read all instructions before using this heater.
1.
a heater has hot and arcing or sparking parts inside. Do
2.
not use it in areas where gasoline, paint or flammable
liquids are used or stored.
This heater is hot when in use. To avoid burns, do not let
3.
bare skin touch hot surfaces. If provided, use handles
when moving this heater. Keep combustible materials
such as: furniture, pillows, bedding, papers, clothes and
curtains away from heater.
To prevent a possible fire, do not block air intakes or
4.
exhaust in any manner. Do not use on soft surfaces like
a bed where openings may become blocked.
Do not insert or allow foreign objects to enter any venti
-
5.
lation or exhaust opening as this may cause an electric
shock or fire, or damage the heater.
SAve THeSe inSTrucTiOnS
Wall installation
Unpack the heater from the carton and lift the front/top
1.
panels up & off the heater.
Remove the desired terminal box covers(s) and sup-
2.
ply wire entry knockouts from the terminal boxes. (See
Figure 1 for locations)
!
nOTe:
it is only necessary to remove the knockout(s)
that will feed the power supply wiring, keeping in mind
the heater mounting location and supply wire location in
the wall.
Determine the correct mounting height and scribe or
3.
snap a level line on the wall to maintain each heater back
plate in a horizontal alignment, when mounting.
!
nOTe:
Bottom air inlet heaters must be mounted a
minimum of 2” from the bottom of the heater to the
finished floor.
Mount the back plate to the wall using suitable fasteners
4.
(provided by the customer) using the scribed line on the
wall to keep the heater level.
!
nOTe:
Should the wall surface be uneven, secure
the heater back panel to the high spots. This will avoid a
distorted appearance.
proceed to the wiring instructions.
5.
Floor installation
Unpack the heater and pedestal(s) from the carton( the
1.
pedestals are packed at the end of the carton) and lift the
front/top panels up and off the heater.
Disassemble the pedestal base from the pedestal pad.
2.
Remove the desired terminal box cover(s) and supply
3.
wire entry knockouts from the terminal boxes. (See
Figure 1)
1.5 in
(3.81 cm)
min
1.5 in (3.81 cm)
min
1.5 in (3.81 cm)
min
3 in (7.62 cm)
min
3 in (7.62 cm)
min
3 in (7.62 cm)
min
6 in (15.24 cm)
min