![Dimplex 6910470100 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/dimplex/6910470100/6910470100_service-manual_2504636017.webp)
17
Troubleshooting
Problem
Display
Cause
Solution
Error Code is displayed
Err19
Media bed LEDs not detected
Media Bed LEDs disconnected.
Defective Media Bed LEDs.
Defective Main Control Board
Err 21
Flame LEDs not detected
Flame LEDs disconnected.
Defective Flame LEDs.
Defective Main Control Board
Err 22
Flicker motor not detected
Flicker motor is disconnected.
Defective Flicker motor.
Defective Main control board.
Err 23
Relay board not detected
Relay board is disconnected.
Defective Relay board.
Err 24
Main control board not detected
Main control board is
disconected.
Defective Main control board.
Err 25
Display board not detected
Defective Display board.
Defective Main control board.
1-888-346-7539 | www.dimplex.com
In keeping with our policy of continuous
product improvement, we reserve the
right to make changes without notice.
© 2022 Glen Dimplex Americas
A BRAND OF GLEN DIMPLEX AMERICAS
REV
ECO
DATE
00
ECO-000279
21-JUL-21
01
ECO-000441
24-MAY-22
App
For troubleshooting information related to the Flame Connect app, please visit