Solid brick or concrete block walls must be drilled and plugged (using a spirit level
as a guide ensure bracket is level), due to different types of wall constructions
fixings are not included, ensure the correct fixings are used. The plug must be
located in the solid part of the wall, not just in the plaster layer.
For panelled internal walls or ceilings, it is best to locate the studding, position the
heater fixing bracket accordingly and use screws supplied. If it is not possible to
locate the studding, use type M5 Rawlplug inserts, making the 10mm holes with a
drill rather than a bradawl or a screwdriver.
Locate the heater on the mounting bracket ensuring that the pozi- head screws are
fully engaged in the slots of the bracket.
It is important that the serrated metal washer (a) is located between the heater
holding bracket (b) and the wall mounting bracket (c). Adjust heater to the required
angle then firmly tighten the fixing screw (d) inside the endcap (e) using a cross-
head screwdriver (f) as shown in
Fig. 4.
Wall or Ceiling Mounting
This appliance may be either wall-mounted or fixed to a ceiling - see
Fig. 2
for
various fixing positions and ‘Installtion’ see section below, for details on fixing.
Heaters may be mounted end to end for wide doorways.
Installation
Using the wall mounting bracket as a guide (see ‘a’ in
Fig. 3
) mark off the hole
positions on the wall or ceiling (see ‘B’ in
Fig. 1
). A minimum height of 1.8 metres
is required from floor to bracket. Fix the bracket in position by following steps as
described under the heading ‘Wall or Ceiling Mounting’.
Electrical
The installation of this appliance should be carried out by a competent electrician
and be in accordance with the current IEE wiring regulations.
Electrical Connection
Ensure that the heater is securely fastened and that the supply cable is firmly
clamped before operating the appliance.