Summer Mode 

 

 

 

 

 
The “

SUMMER MODE

” feature temporarily disables the circulation pump 

“Cool Off” cycle. During hot weather the spa can experience “Heat Creep”. 
Heat creep is caused when the spa, during normal maintenance operations, 
cannot dissipate more heat than is generated. This may cause the spa 
temperature to exceed the set temperature and cause a “Cool Off” cycle. In 
order to prevent the water from becoming cloudy due to the circulation pump 
being turned off by the “Cool Off” cycle, the spa can be set to bypass the 
“Cool Off” cycle. This is accomplished by setting the spa in the “

SUMMER 

MODE

”.  

 
To initiate a “

SUMMER MODE

”, use the 

Up

 and 

Down Buttons

 to set the 

temperature to 15

°

C (

59

°

 F). The Digital Display Window will indicate 

SUMMER MODE

”. In this mode the pump will run continuously until the 

water temperature reaches 41

°

 C (

107

°

F) and then turn off. It will remain off 

until the water temperature reaches 38

°

 C (

102

°

 F) at which point the pump 

turns on. 

Standby Mode 

 

 

 
The “

STANDBY

” mode allows the user to clean the filter without turning off 

power to the spa. This feature disables all automatic and manual functions. 
 
To enter the “

STANDBY

” mode press and hold the Dimension One Spa’s 

ICON Logo

®

 Button for 5 seconds. To exit the mode, press and hold the 

Logo Button for 5 seconds.  
 
If you do not exit the mode manually, the spa will automatically return to 
normal functionality after 24 hours. 
 

 

 

Note

 

 
The “

Smart Winter

” mode is not affected by the use of the 

Standby

”: mode. 

Programming the Scrolling Message Center 

Your Scrolling Message Center is the most advanced in the industry and can virtually walk you through 
customizing your hot tub to your exact needs. To initiate the programming sequence at any time, push and 
hold the Program Button for 3 seconds. If, within 10 seconds, you do not proceed with the hot tub 
programming, the hot tub will automatically exit the programming sequence and revert to the pre-set factory 
default settings. To exit the programming sequence at any time, push the Enter Button or do not press any 
button for 10 seconds. Any programming changes made up to that point are saved. 

Setting the Time 

After holding the 

PROGRAM Button

, the top line of the Digital Display Window will read “

SET TIME OF 

DAY

” and the bottom line will read “

PUSH UP OR DOWN TO CHANGE - PUSH PROGRAM TO 

SELECT NEXT FUNCTION - PUSH ENTER TO EXIT

 ”. Push the 

UP 

or

 DOWN Buttons

 to engage the 

time setting mode. The time screen will appear with “hours” (_ _.00) flashing on and off. Push the 

UP 

or

 

DOWN Button

 to increase or decrease the number until the desired hour appears. When the desired 

number is displayed, push the 

LIGHT Button

 to accept the selection and change the flashing number to the 

“ten minute” place (12:_0). Adjust the number with the 

UP 

or

 DOWN Button

 in the same manner as the 

hour number. When the desired indicator is displayed, push the 

LIGHT Button

 to accept the selection and 

change the flashing number to the “minute” place (12:1_). Adjust this number with the 

UP

 or 

DOWN

 

 

28

Содержание 2003 Sarena Bay

Страница 1: ......

Страница 2: ...2003 Sarena Bay Export Owner s Manual ii...

Страница 3: ...io Wall Bench Seat 8 Bench Seat 9 Pivot Seat 9 Frontal Therapy Seat 10 Sport Zone Seat 10 Additional Design Features 11 Top Side Control 11 Dynamic Massage Sequencer 12 Fountain 12 Synchronous Spa Lig...

Страница 4: ...g Display and or Check Water Level 27 Erroneous Temperature on the Display 27 Ice 27 Cooling 27 Summer Mode 28 Standby Mode 28 Programming the Scrolling Message Center 28 Setting the Time 28 Filter Cy...

Страница 5: ...r 38 ROUTINE EQUIPMENT MAINTENANCE 39 DRAINING YOUR EQUIPMENT 39 FILTER CLEANING 39 LIGHT BULB REPLACEMENT 40 SURFACE CARE 40 Ultralife Shell 40 Dimension One EnviroTect Skirts and Vinyl Covers 41 Car...

Страница 6: ...2003 Sarena Bay Export Owner s Manual vi...

Страница 7: ...5 feet of the spa Danger Risk of Serious Injury or Death The suction fittings in this spa are sized to match the specific water flow created by the pump Should the need arise to replace the suction f...

Страница 8: ...F Warning To Reduce the Risk of Injury The use of alcohol drugs or medication before or during spa use may lead to unconsciousness with the possibility of drowning Warning To Reduce the Risk of Injur...

Страница 9: ...essure any condition requiring medical treatment pregnant women the elderly or infants should consult with a physician before using a spa Caution The consumer products safety commission has stated tha...

Страница 10: ...the spa Do s and Don ts Do DO read all operating instructions DO read understand and follow all Safety Danger and Warning instructions before use DO test water temperature with your hand before enter...

Страница 11: ...a Warning Sign and an Important Notice label This label outlines safety precautions This sign should be permanently placed in a location that is visible to the spa user Replacement signs can be obtai...

Страница 12: ...You can even remove the fountain cone and create a soothing Bubbler Nothing says relax like the sound of moving water These variables provide customizable AudioTherapy to suit your special desires Th...

Страница 13: ...2003 Sarena Bay Export Owner s Manual Revolutionary Design Features Innovative Seating For 7 7...

Страница 14: ...eckFlex Jet Pillow Height adjustable neck therapy Dynamic Massage Sequencing lounges Personalized and controllable dynamic massages using our sequencing technologies in each lounge Personal Therapy Co...

Страница 15: ...able jets Barrier free Pivot Seat This seat has an extra large back that functions as a regular large spa seat and also allows you to pivot your position and sit in a lounge style position to utilize...

Страница 16: ...omfort and security Ultra low seating Allows for better HydroTherapy and total shoulder immersion for most users Unique jetting pattern Designed around specific neck shoulder and side muscle groups Pe...

Страница 17: ...ures Top Side Control Scrolling Message Center Provides full control of all spa functions displays status informational and error messages in the Digital Display Window For more information on using t...

Страница 18: ...rns Customize the fountain look feel and sound by making simple adjustments or adding an optional semi circular fountain head Landscape focal point Fountain makes your spa a focal point of your landsc...

Страница 19: ...erapy Unique design Design is based on standard Reflexology maps Adjustable jets Change flow to suit your needs HydroSport OptiMounts Sport Zone Seat Doubles as a rowing station Design can accept more...

Страница 20: ...he flow of water to your seat by simply turning the valves in a clockwise or counter clockwise direction These valves will divert jet power from one seat within the spa to an adjacent seat Customize y...

Страница 21: ...ve purification system can be used in conjunction with your UltraPure Water Management System The advantage of Vision over conventional halogens bromine and chlorine is that it will as a result of low...

Страница 22: ...tional infrared device that floats It is used to Jets a Light The versatile HydroSport Aquatic Fitness Gear is all you need for a variety of aquacizing options Sonic Immersion System SIS T superior fi...

Страница 23: ...w the Top Side Control and the right side to expose the pumps and the Lower Equipment Compartment 6 There are two pump unions and two gate valves per pump The pump on the left in the picture shows the...

Страница 24: ...r Filter 11 Then remove the foam blocks securing each filter 12 Next remove the filters from the Weir Skimmer and UltraPure canisters and fill your hot tub by placing a hose through the empty UltraPur...

Страница 25: ...until jets function properly Note Ozone bubbles will continue to release from the skimmer recess Ultra Pure bleeder valve as long as the valve remains open Once the pumps are primed be sure that the b...

Страница 26: ...F to 5 5 C 10 F per hour 13 After completing the above steps it is necessary to ensure proper water chemistry See the Water Care Guide for easy steps to maintaining clean and safe water The schedule...

Страница 27: ...tub to enjoy complete control of all hot tub functions Safety is assured through design concepts and materials that meet or exceed the most stringent requirements of European Standards EN60335 1 94 E...

Страница 28: ...re the pump will turn off is displayed immediately following the pump speed message The pump automatic shut off cycle is programmed separately All pumps are controlled by the same automatically shut o...

Страница 29: ...e a safety device that will reduce wear and tear on your equipment and reduce energy costs by ensuring that your pumps don t run constantly When the Up or Down Button is pushed to change the set tempe...

Страница 30: ...Color Hold Turn off for 1 second back on again for Color Fade Fast Turn off for 1 second back on again for Color Hold Turn off for 1 second back on repeats to Color Fade Slow Turn off for 5 or longer...

Страница 31: ...lt is Fahrenheit Pressing the logo for 5 seconds will place the spa in the Standby mode and allow the spa to be cleaned without turning off the power Scrolling Message Center Messages Because of the a...

Страница 32: ...ECK UP is displayed on the Digital Display Window we recommend that you have your hot tub inspected by your dealer as a preventative maintenance measure To reset this message push and hold the Dimensi...

Страница 33: ...the equipment can has gone below a factory preset level and the system has activated Smart Winter Mode It will then automatically activate the pump s to circulate water Ice Feature This is a normal h...

Страница 34: ...after 24 hours Note The Smart Winter mode is not affected by the use of the Standby mode Programming the Scrolling Message Center Your Scrolling Message Center is the most advanced in the industry and...

Страница 35: ...will also activate for 1 minute on high speed and then turn off Filter Cycle Duration After setting the filter cycle start time the top line of the Digital Display Window will read SET CYCLE DURATION...

Страница 36: ...oose 2 hours when you push the Water Feature Button the Waterfall will run for 2 hours before shutting down automatically The pre set factory default is 1 Digital Display Window Invert The invert feat...

Страница 37: ...M Button Programming Unlock To unlock the Panel The following buttons must be pushed within 3 seconds 1 Push the ENTER Button 2 Push the ENTER Button 3 Push the Dimension One Spas ICON logo Button Whe...

Страница 38: ...equence before a selection is confirmed Control Panel Description LIGHT Button The LIGHT Button is used to turn the spa light on or off The status light below the button will illuminate when the light...

Страница 39: ...USE Button and the system will remain in the specific configuration until the button is pushed again The BEGIN PAUSE Button status light will be on when the system is in the Pause mode During this mod...

Страница 40: ...back shoulders and thoracic muscle groups There are two rotating VCR Jets which are water volume controllable and can be adjusted to change the area of coverage and the speed of the rotational pattern...

Страница 41: ...n SEQUENCE 3 activates alternate zones It sequences Zones A C and E first then switches to Zones B D and F second The time interval between Zone Groups is determined by the Speed Button SEQUENCE 4 act...

Страница 42: ...add an optional semi circular spreader to your fountain to change the fountain s blossom to a blossom This item is available from your authorized D1 Spas Dealer or from our Virtual Showroom at www D1S...

Страница 43: ...andard VCR Jets Rotator Feature A variety of additional jets are available from your authorized D1 Spas Dealer that you may select and interchange with this jet to enhance your enjoyment Standard VCR...

Страница 44: ...er clockwise direction until you feel it release will allow you to remove the jet and replace it with a Mini VCR Jets Rotator Euro Jets Directional These jets are rated at 22 7 LPM 6 GPM and may be ad...

Страница 45: ...clean the skimmer filter cartridge lift the center float of the skimmer assembly until it is fully extended Hold the centerpiece of the assembly and turn it counterclockwise until the flats of the bas...

Страница 46: ...rvice Department to have one sent Note Be sure the O ring is not damaged and is properly in place when replacing the lens Contact Dimension One Spas if a replacement O ring is needed Surface Care Ultr...

Страница 47: ...oing just that while relaxing in their hot tub with family and friends Therefore the best winterizing tips of all are to enjoy use of your system year round All systems manufactured by Dimension One S...

Страница 48: ...is to each jet face one jet at a time Be careful as water will be coming out of each jet fitting as you perform this maneuver Perform this operation until no more water is coming from the jets 11 Remo...

Страница 49: ...you may want to take one more extra precaution to safeguard the life of your system cover Span the cover with 2 or more 2x4 s cut to length to reach the outside edges of your cover Place a sheet of p...

Страница 50: ...o reach desired temperature because the set temperature is not turned up high enough Maximum thermostat setting is approximately 40 C 104 F 3 Burned out hot tub light Bulbs are not covered 4 Hot tub w...

Страница 51: ...ight of the Top Side Control Panel Jets Return the water into the spa from the equipment The jets produce a turbulent flow of water mixed with air to provide a concentrated body massage Light Illumina...

Страница 52: ...ptimizes heat recovery using the amperage that you have available Along with computerized load sharing that automatically recognizes the number of jet pumps in use compares it with the available power...

Страница 53: ...the number of filter cycles and or the filter cycle duration 2 Temperature setting too high 2 Turn down the thermostat Display reads OVERHEAT 3 High limit or sensor problem 3 Call for service Electric...

Страница 54: ...ill with water to the bottom of the OptiMount located next to the Skimmer Filter Basket 1 Jets are turned off 1 Turn jets on by turning jet face clockwise 2 Diverter Valve turned 2 Turn the Diverter V...

Страница 55: ...2003 Sarena Bay Export Owner s Manual 49...

Страница 56: ...2003 Sarena Bay Export Owner s Manual 50...

Отзывы: