Before connecting to the mains, make sure that:
The electricity meter, safety valve, feeding line and socket are adequate to withstand the maximum load
required (refer to product data label for maximum load)
The supply system is regularly earthed, according to the regulations in force.
The isolation switch can easily be reached after the oven is installed.
After connection to the mains, check that the supply cable does not overheat.
Never use reductions, shunts, adaptors that can cause overheating or burning.
The supply cable must be positioned so that it does not exceed 50
°
C above room temperature at any point of
its length.
The manufacturer shall not be liable for any direct or indirect damage caused by faulty installation. The installer
must ensure that the product installation and connection complies with the local and general regulations in force.
Installation Instruction
Fit the appliance into the cabinetry by inserting screws into the 4 holes that can be seen in the frame of the
oven when the door is open. Do not forget to place the special spacers provided between the hole and the
screw itself.
The sides and the face surface where the oven is to be installed should be milled to allow sufficient air intake
and circulation around the oven, to avoid causing any damage to the cabinetry.
Ensure the oven in secured firmly in place as described above, and insulate electrical connections in order to
avoid contact with metallic parts. Any protective parts must be secured so that they can only be removed with
the use of tools. The adhesive joining the rolled sections to the cabinet has to withstand at least 120°C of heat
to avoid deformations or instability.
For the most efficient air circulation, the oven should be fitted according to the dimensions shown. The rear
panel of the cabinet must be removed so that air can circulate freely. The panel to which the oven is fitted
should have a gap of at least
70 mm
at the rear. To provide adequate ventilation, there must be appropriate
ventilation openings in the front bottom and the top part of 200cm
2
, and an exhaust opening at the bottom of
at least 200cm
2
, and an exhaust opening of at least 60cm
2
.
Do not switch on the appliance before it has been fully and correctly installed.
Page
3
Version 1.0
Sept 2018