![Dillon FI-521 Series Скачать руководство пользователя страница 28](http://html.mh-extra.com/html/dillon/fi-521-series/fi-521-series_user-instructions_2502414028.webp)
28
FI-521 User Manual
COM2
BAUD.RT
1200
9600
Select COM2 baud rate
2400
4800
9600
19200
28800
57600
BYT.FMT
8N1
8N1
Select COM2 byte format
(1)8N1=8 data bits, No parity
check bit, 1 stop bit
7O1
(2)7O1=7 data bits, 1 Odd
parity check bit, 1 stop bit
7E1
(3)7E1=7 data bits, 1 Even
parity check bit, 1 stop bit
OUT.MOD
NONW
NONE
Select COM2 output mode
(1)NONE = COM2 disabled
CONT
(1)CONT=continuously output
(2)PRINT=output after PRINT
key pressed
CMD
(3)CMD=output after a request
command is received
PRT.CMD
(4)PRT.CMD= output after
PRINT key pressed or request
command received
STABLE
(5)STABLE=output after scale
is stable; Note: use PRINT or
CMD to output data, the scale
must be stable
LAYOUT
MULTPL
MULTPL
Set COM2 content and format
(1)MULTPL= the following
selected item in OUT2 will be
output use defined format
SINGLE
(2)SINGLE= only displayed
content and current status will
be output, it's compatible with
NCI-SCP01
EDX
(3)EDX= only displayed content
and current status will be
output. Compatible with EDX
LC.ADDR
00-99
01
Local address for COM2
EN.ADDR
NO
NO
Enable or disable COM2 local
address in output or input
strings
YES
USER
SubMenu1
SubMenu2
Option
Default
Parameter Description
Comment
Содержание FI-521 Series
Страница 1: ...FI 521 Indicator Series User Instructions AWT 35 501775 Issue AA ...
Страница 51: ......