Hardware Description  

5.1 Front Panel    

The Front Panel consists of Ethernet Ports. The LED indicators are also 

located on the panel. 

DN-80112-1 

 

 

 

 

LED indicators 

16x10/100/1000Mbps port

 

 

 

 

DN-80113-1 

 

 

 

 

LED indicators 

DIP Switch 

24x10/100/1000Mbps port 

 

 

DIP Switch (Only for DN-80113-1) 

The DIP switch located on the left panel.  

 

Default

: the factory default mode, can normal communication between 

port 1~24. 

 

VLAN

: 1-22 port can be isolated each other but 1-22 port can connect to 

23-24 port after open VLAN to stop broadcast storm to increase 

forwarding rate of frame. 

 

 

LED indicator 

LED 

Color 

Function 

PWR 

Green  Off: No Power supply. 

Light: Indicates the switch has power. 

LNK/ACT  Green 

Off: No device is connected to the corresponding port. 

Light: Indicates the link through that port is successfully  

           established at 10/100/1000Mbps. 

Blink: Indicates that the Switch is actively sending or 

           receiving data over that port. 

 

 

Содержание DN-80112-1

Страница 1: ...16 24 Port Gigabit Switch Quick Installation Guide DN 80112 1 DN 80113 1 ...

Страница 2: ...uplink ports It uses store and forward technology in combination with the dynamic memory allocation for each port The integrated VLAN function can improve the network environment and reduces network maintenance costs The DN 80113 1 is easy to manage and maintain 2 Main feature Flow control for full duplex operation and back pressure for half duplex operation Supports VLAN mode Only for DN 80113 1 ...

Страница 3: ...tore and Forward Frame Forward Rate 10Base T 14881pps Port 100Base TX 148810pps Port 1000Base T X 1488095pps Port Switching Capacity 32Gbps 48Gbps Forwarding Rate 23 8Mpps 35 7Mpps Packet buffer 4 1M bit Dimensions LxWxH 280 x 180 x 44 mm Fan Fanless Power Input AC 100 240V 50 60Hz Temperature Operating Temperature 0 C 40 C 32 F 104 F Storage Temperature 40 C 70 C 40 F 158 F Humidity Operating Hum...

Страница 4: ...ode can normal communication between port 1 24 VLAN 1 22 port can be isolated each other but 1 22 port can connect to 23 24 port after open VLAN to stop broadcast storm to increase forwarding rate of frame LED indicator LED Color Function PWR Green Off No Power supply Light Indicates the switch has power LNK ACT Green Off No device is connected to the corresponding port Light Indicates the link th...

Страница 5: ... how to install your Ethernet Switch and make connections to it Please follow the following instructions in avoid of incorrect installation causing device damage and security threat Before cleaning the switch unplug the power plug of the switch first Do not clean the switch with wet cloth or liquid Do not place the switch near water or any damp area Prevent water or moisture from entering the swit...

Страница 6: ...tch on a desktop please attach these cushioning rubber feet provided on the bottom at each corner of the Switch in case of the external vibration Allow adequate space for ventilation between the device and the objects around it as example below ...

Страница 7: ...d on an EIA 19 inch equipment rack To do this first please install the mounting brackets on the switch s side panels one on each side secure them with the included screws and then use the screws provided with the equipment rack to mount the switch on the 19 inch rack as example below ...

Страница 8: ...ore power on otherwise the switch will be damaged The power input is 100V 240Vac 50 60Hz This is a Class A product In home environment this product may cause radio interference In this case the user may be required to take appropriate measures Hereby Assmann Electronic GmbH declares that the Declaration of Conformity is part of the shipping content If the Declaration of Conformity is missing you c...

Отзывы: