background image

4.5 Power supply

:

 

input voltage: DC12

-52V (two-way 

power redundancy backup); Access 

terminal: Phoenix terminal, 

Support dual power redundancy; 

Support built-in over current 4.0A 

protection; 

Support reverse connection 

protection

 

4.6 Mechanical Characteristic: 

IP40 aluminum housing  

DIN rail install 

Natural colling, no fan

 

Weight

:

 

0,9Kg 

Measurement

:

 

175.6 x 135 x 45.5 mm 

4.7 Industrial standard

:

 

FCC CFR47 Part 15, 

EN55022/CISPR22, Class A 

IEC61000

-4-

2 (ESD): ±8kV 

(contact), ±12kV (air)

 

IEC61000-4-3 

(RS): 10V/m (80~1000MHz)

 

IEC61000-4-

4 (EFT): Power Port: 

±4kV; Data Port: ±2kVIEC61000

-4-5 

(Surge):

 

Power Port: ±2kV/DM, 

±4kV/CM; Data Port: 

±2kVIEC61000

-4-

6 (CS): 3

V (10kHz-

150kHz); 10V (150kHz-80MHz) 

IEC61000-4-16 (Common mode 

conduction): 30V (cont.), 300V (1s)

 

Frequency range

 

150kHz-80MHz 

Impact

:

 

IEC 60068-2-27 

Free Fall

:

 

IEC 60068-2-32 

Vibration

:

 

IEC 60068-2-6 

 

Содержание DN-651129

Страница 1: ...INDUSTRIAL 16 PORT GIGABIT SWITCH UNMANAGED Quick Installation Guide DN 651129 ...

Страница 2: ...s housing and LED indicator light make the DN 651129 a plug and play industrial grade device providing a reliable and convenient solution for users to network their Ethernet devices 2 Switch Panel DN 651129 Side panel P1 and P2 are the number of connecting terminals P 1 and P 1 are respectively to the positive and negative poles to be connected Earthing screw used for earthing equipment DN 651129 ...

Страница 3: ...n Internal storage and forwarding mechanism support a variety of protocols In line with industrial operating standards the average trouble free work in more than 300 000 hours Working power supply DC 12 52V to provide reverse protection Lightning Surge Protection Power 5000A 8 20μs 4 Specification 4 1 Standard IEEE802 310BASE TIEEE802 3i 10Base T IEEE802 3u 100Base TX FX IEEE802 3ab1000Base T IEEE...

Страница 4: ...ling no fan Weight 0 9Kg Measurement 175 6 x 135 x 45 5 mm 4 7 Industrial standard FCC CFR47 Part 15 EN55022 CISPR22 Class A IEC61000 4 2 ESD 8kV contact 12kV air IEC61000 4 3 RS 10V m 80 1000MHz IEC61000 4 4 EFT Power Port 4kV Data Port 2kVIEC61000 4 5 Surge Power Port 2kV DM 4kV CM Data Port 2kVIEC61000 4 6 CS 3V 10kHz 150kHz 10V 150kHz 80MHz IEC61000 4 16 Common mode conduction 30V cont 300V 1s...

Страница 5: ...pin definition is shown in the following figure RJ45 port supports automatic MDI MDI X operation you can use a straight line to connect to the PC or server connect to other switches or hubs In the through line MDI pins 1 2 3 4 5 6 7 8 correspond to the connection For the MDI X port of a switch or hub cross lines are used 1 3 2 6 3 1 6 2 4 7 5 8 7 4 8 5 10Base T 100Base T X pins are defined as foll...

Страница 6: ...injury caused by improper use please follow the following precautions In order to avoid damage caused by falling of the equipment please put the equipment in a stable environment When supplying power to the equipment pay attention to confirm the range of power supply voltage as well as the positive and negative poles of the power supply so as not to damage the equipment by wrong operation In order...

Страница 7: ...the guide rail and the switch are fixed on the guide rail vertically and stably 7 3 Grounding Fix the grounding wire to the grounding screw above the switch and ensure good reliable connection of the grounding system 7 4 Power Connection Insert the power cord into the specified position of the 6 core terminal and insert the terminal into the standard power supply inlet P 1 and P 1 input correspond...

Страница 8: ...e the user may be required to take appropriate measures Hereby Assmann Electronic GmbH declares that the Declaration of Conformity is part of the shipping content If the Declaration of Conformity is missing you can request it by post under the below mentioned manufacturer address www assmann com Assmann Electronic GmbH Auf dem Schüffel 3 58513 Lüdenscheid Germany ...

Отзывы: