tecHNology fiNgerpoSt

type

technical

dn-170013

dn-170014

dn-170015

imput voltage

ac110v/120v or 220v/2360v/240v ± 23%

output voltage

ac110v/120v or 220v/2360v/240v ± 10% 

(With avR)

output power

650va

1000va

1500va

charge time

8 hours float charging to 90% of full potetial

frequency

50/60hZ ± 10%

battery

12v/5.0ah or 7.0ah

12v/5.0ah or 7.0ahx2

12v/7.0ah or 9.0ahx2

output Wave form

modified sinewave

transfer time

≤ 10ms

surrounding temperature

-5°c - 40°c

surrounding humidity

10% - 90%

Weight

5.5 kgs

10.0 kgs

11.5 kgs

size (mm)

335 x 95 x 160

350 x 120 x 195

function

cold start

it enables to activate ups without utility power

automatic recharge

auto charge even though ups is off

protection

short circuit / over load

fuse & current limited for both mains and battery mode

low battery

tow stages; no battery drain after cut off

over voltage / low voltage

switch to bat. o/p when mains over regulation range

comment

equipment for computer only

for batteries: please recycle only complete discharged batteries