background image

 

  

  

 

 

 

Ordercode: 75001S/75001B 

50 mm SlimLine Half Coupler 100 kg 

Table of contents 

 

Warning ........................................................................................................................................................................... 2

 

Safety Instructions ..................................................................................................................................................... 2

 

Operating Determinations ....................................................................................................................................... 3

 

Rigging ........................................................................................................................................................................ 3

 

Return Procedure ...................................................................................................................................................... 4

 

Claims ......................................................................................................................................................................... 4

 

 

Description of the device ............................................................................................................................................. 5

 

Overview .................................................................................................................................................................... 5

 

 

Installation ...................................................................................................................................................................... 6

 

 

Set Up and Operation ................................................................................................................................................... 6

 

Inspection Before First Use ....................................................................................................................................... 6

 

Installing the Half Coupler ........................................................................................................................................ 6

 

 

Maintenance .................................................................................................................................................................. 7

 

Inspection & Maintenance Intervals ...................................................................................................................... 8

 

Regular Inspections ................................................................................................................................................... 8

 

 

Product Specifications .................................................................................................................................................. 8

 

 

Notes ................................................................................................................................................................................ 9

 

 

 
 

 

Содержание DN-16100-2

Страница 1: ...50 mm SlimLine Half Coupler 100 kg V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 75001S 75001B MANUAL ENGLISH ...

Страница 2: ...s 2 Operating Determinations 3 Rigging 3 Return Procedure 4 Claims 4 Description of the device 5 Overview 5 Installation 6 Set Up and Operation 6 Inspection Before First Use 6 Installing the Half Coupler 6 Maintenance 7 Inspection Maintenance Intervals 8 Regular Inspections 8 Product Specifications 8 Notes 9 ...

Страница 3: ...on it is absolutely necessary for the user to follow the safety instructions and warning notes written in this manual Please consider that damages caused by manual modifications to the device are not subject to warranty This device contains no user serviceable parts Refer servicing to qualified technicians only IMPORTANT The manufacturer will not accept liability for any resulting damages caused b...

Страница 4: ... out by a qualified technician WARRANTY Till one year after date of purchase Operating Determinations This device is not designed for permanent operation Consistent operation breaks will ensure that the device will serve you for a long time without defects If this device is operated in any other way than the one described in this manual the product may suffer damages and the warranty becomes void ...

Страница 5: ... 03 Your phone number 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check after our announcement that the goods are at their disposal Damage incurred in shipping is the responsibility of the shipper therefore the damage must be reported to the carrier up...

Страница 6: ... kg Description of the device Features The 50 mm SlimLine Half Coupler has a slotted base suitable for M10 nuts Maximum load capacity SWL 100 kg Fixing M10 bolt Tube diameter 48 51 mm Material Aluminum extrusion Color Metal 75001S Black 75001B Overview Fig 01 ...

Страница 7: ... Before installation operators must be instructed and fully understand the safe use of the equipment Before each use the Half Coupler has to be inspected on the following points Overall operation of the Half Coupler itself Mounting of the Half Coupler onto the structure Make sure that the Half Coupler shows no trace of visual defects Installing the Half Coupler 01 Loosen the Half Coupler by turnin...

Страница 8: ...ring the inspection 01 All screws used for installing the device or parts of the device have to be tightly connected and must not be corroded 02 There may not be any deformations on housings fixations and installation spots 03 Mechanically moving parts like axles eyes and others may not show any traces of wearing The 50 mm SlimLine Half Coupler requires almost no maintenance However you should kee...

Страница 9: ...pection by an expert X Regular Inspections Regardless of national rules in the country of use the Half Coupler has to be inspected by an expert at least once a year In case of heavy frequent usage the inspection and maintenance intervals need to be more regular Check the Half Coupler carefully to make sure that there are no unusual noises that could indicate faults or excessive wear Make sure all ...

Страница 10: ...9 Ordercode 75001S 75001B 50 mm SlimLine Half Coupler 100 kg Notes ...

Страница 11: ...10 Ordercode 75001S 75001B 50 mm SlimLine Half Coupler 100 kg ...

Страница 12: ... 2017 Showtec ...

Отзывы: