db CodeLock
Version 1.3
Digitus Biometrics, Inc. 2017
Page 9 of 10
Connect the SENSE OUT to monitor the lock position (open/closed)
If the 3
rd
-party Access Panel requires a 2-wire input to monitor the door positions, an external relay is required.
Connect as follows:
Black
Wire
3
rd
-party Access Panel
C
NO NC
+V
0V
External
Relay
+V 0V
SENSE OUT. Connect to
Blue/White Wire from Lock.
DOOR
SWITCH
INPUT
Yellow
Wire
Blue
Wire
Red
Wire