Digitrax BXP88 Скачать руководство пользователя страница 12

© 2017 Digitrax, Inc.

www.digitrax.com

— 12 —

10.3 Panel Indicator Wiring

You can build a display panel with a track schematic and LEDs to indicate track 
occupancy by connecting LEDs to the LT5 compatible output connectors on the 
BXP88. For a panel display of occupancy status made up with user supplied 
LEDs, connect to the four 0.1” 2x5 headers, and wire up high brightness LEDs 
as shown in Figure 3: LED Panel Indicators Wiring. The plugs and ribbon cable 
included in the Digitrax SDCK Signal Driver Cable Kit can be used. 

The BXP88 incorporates current setting resistors to set the LT5 LED current typi-
cally to about 1~3mA. If you need higher LED drive currents you can use external 
transistors etc. to amplify the LED current.  

The LT5 header drive from the BXP88 is active high at about +3.5 volts, via a 
1 Kohm resistor. Note that the ribbon cable includes separate ground return 
conductors for each LED that allow a 10 conductor ribbon cable to be split into 5 
pairs to conveniently routed to individual LEDS. Be sure to connect the +ve active  
detection section output wires to the LED anodes. Do not connect any LT5 wiring 
to other voltages as this may cause damage and void the warranty. 

Figure 2: LT5 Tester

LED for DS1 or DS5

LED for DS3 or DS7

Zone Power LED

LED for DS2 or DS6

LED for DS4 or DS8

Ribbon Cable and Plug

DS1 or DS

5

DS

4

 or DS8

DS2 or DS

6

DS3 or DS

7

Zone Power

Figure 3: LED Panel Indicators Wiring

Содержание BXP88

Страница 1: ...ipped locos and rolling stock Plug and Play with Digitrax DCC systems with automatic Railsync polarity detection LED output headers for front panel indication of Detection Section occupancy Transponding and power status Easy connect pluggable track wire terminal blocks can plug in straight or at right angles 3 Amp capacity per Detection Section 8 Amp total unit capacity Automatically updates statu...

Страница 2: ...r current power management This allows for more reliable layout operations by preempting most booster shutdowns On your Digitrax system the BXP88 reports detection section occupancy transponding and track power status to the system via its LocoNet connection This makes occupancy and transponding information available for use by any LocoNet device hooked up to LocoNet For instance the information c...

Страница 3: ...a loco or other specially equipped cars in that section of track and identify transponding equipped locos and rolling stock Traditionally with BDL168 RX4 combinations Detection sections could be combined inside Transponding Zones With the BXP88 each of its 8 Detection Sections act as both an occupancy and transponding detector For simplicity these sections will be referred to as Detection Sections...

Страница 4: ...ue layout with the number and length of a detection sections varying depending on your layout train length and the purpose of the detection transponding The BXP88 provides Detection Tran sponding and Power Management in each of its 8 detection sections you should consider if every section on your layout needs these features Transponding is often not needed in all detection sections of your layout ...

Страница 5: ...d as needed to match existing wiring the BXP88 automati cally sets railsync An LT5 tester is included with the BXP88 and optional fascia LED panels can be constructed following the instructions in section 10 3 The BXP88 does not need to be externally powered An optional auxiliary 9V 150ma DC power supply may be used to allow the BXP88 to remain on when track power is lost Multiple BXP88s can be po...

Страница 6: ...using a known good LocoNet Cable 10 Connect optional auxiliary 9V 150ma DC power supply using the power barrel plug connector See Figure 1 BXP88 Installation Example for a typical installation 6 0 Turning on your system and configuring the BXP88 Once you have installed your BXP88 you may turn on your system There are several tests you can perform to ensure that the BXP88 is properly functioning 1 ...

Страница 7: ...RUN OP SLEEP SCALE O G N HO P A G R P B R B R A 5A LOCO RESET 8A Detection Section 1 Detection Section 2 Detection Section 3 Detection Section 4 Detection Section 5 Detection Section 6 Detection Section 7 Detection Section 8 Figure 1 BXP88 Installation Example General Return LocoNet to other devices LT5 LED connectors DS5 DS8 LT5 LED connectors DS1 DS4 Common Rail A Isolated Rail B detection secti...

Страница 8: ...hold the ID button for approximately 4 seconds until the ID LED flashes red then release it The ID LED will flash alternating red and green This let s you know that you are in board address set up mode 3 Connect a Digitrax throttle to the BXP88s LocoNet port This can only be done with a Digitrax LocoNet throttle or equivalent software 4 Go into SWITCH mode on the throttle Select the switch number ...

Страница 9: ...e set up as desired press the OPS button for about 2 seconds and release it the BXP88 will exit option switch set up mode Option Switch Function Default OpSw 04 c slower short circuit detection t normal short circuit detection t Opsw 05 c transponding enabled t transponding disabled c OpSw 07 c disable fast find t enable fast find t OpSw 10 c enable power manager t disable power manager c Opsw 11 ...

Страница 10: ...ransponding reporting for Detections Section 2 t Opsw 53 c disable transponding reporting for Detection Section 3 t enable transponding reporting for Detections Section 3 t Opsw 54 c disable transponding reporting for Detection Section 4 t enable transponding reporting for Detections Section 4 t Opsw 55 c disable transponding reporting for Detection Section 5 t enable transponding reporting for De...

Страница 11: ...ection section power state and fault information for setup debug and running This will help you with layout wiring and troubleshooting for transpon ding detection LT5 Indications Meaning Detection Section LED on Solid Detection Section is Occupied Detection Section LED is Blinking Slow Detection Section is Occupied and Tran sponding Detection Section LED is Blinking Fast Detection Section is in Sh...

Страница 12: ... to about 1 3mA If you need higher LED drive currents you can use external transistors etc to amplify the LED current The LT5 header drive from the BXP88 is active high at about 3 5 volts via a 1 Kohm resistor Note that the ribbon cable includes separate ground return conductors for each LED that allow a 10 conductor ribbon cable to be split into 5 pairs to conveniently routed to individual LEDS B...

Страница 13: ...ay transponding works Notes If the resistor is not connected between the blue white F0F leads then the locomotive will transpond in only one orientation on the track If you are using a DH126D DH166D TD 1 or TL 1 to equip your loco or rolling stock for transponding you won t need to install the resistor because it is already included in the decoder 3 Enable transponding in the transponder equipped ...

Страница 14: ... 1 Use transponder capable decoder set up with a 470 ohm resistor between the blue and white leads This removes any lamp issues from initial transpon ding tests The motor leads can be left unconnected insulated and all other leads except the red black track connections should be insulated Set CV61 to a value of 02 to enable transponding 2 Ensure the BXP88 is properly connected to your Command Stat...

Страница 15: ... outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Note Any modifications to the equipment not expressly approved by Digitrax voids the user s warranty and compliance with CFR 47 rules as administered by the Federal Communication Commission Digitrax believes any properly installed equipment following guideli...

Страница 16: ...r Road Panama City FL 32404 www digitrax com Need Support helpdesk digitrax com BXP88 LocoNet DCC Occupancy Detector with Transponding and Power Management Made in the USA TM Part 15 Class B RFI Compliant 307 7008 000 ...

Отзывы: