background image

The symbols shown above are internationally accepted
symbols that warn of potential hazards with electrical
products. The lightning flash with arrowpoint in an equilat-
eral triangle means that there are dangerous voltages pre-
sent within the unit. The exclamation point in an equilat-
eral triangle indicates that it is necessary for the user to
refer to the owner’s manual.

These symbols warn that there are no user serviceable
parts inside the unit.

Do not open the unit.

Do not

attempt to service the unit yourself. Refer all servicing to
qualified personnel. Opening the chassis for any reason will
void the manufacturer’s warranty. Do not get the unit wet.
If liquid is spilled on the unit, shut it off immediately and
take it to a dealer for service. Disconnect the unit during
storms to prevent damage.

SAFETY INSTRUCTIONS 

NOTICE FOR CUSTOMERS IF YOUR UNIT IS
EQUIPPED WITH A POWER CORD.

WARNING: THIS APPLIANCE MUST BE EARTHED.

The cores in the mains lead are coloured in accordance
with the following code:

GREEN and YELLOW - Earth     BLUE - Neutral        BROWN
- Live

As colours of the cores in the mains lead of this appli-
ance may not correspond with the coloured markings
identifying the terminals in your plug, proceed as follows:

• The core which is coloured green and yellow must be

connected to the terminal in the plug marked with the
letter E, or with the earth symbol, or coloured green,
or green and yellow.

• The core which is coloured blue must be connected to

the terminal marked N or coloured black.

• The core which is coloured brown must be connected

to the terminal marked L or coloured red.

This equipment may require the use of a different line
cord, attachment plug, or both, depending on the avail-
able power source at installation. If the attachment plug
needs to be changed, refer servicing to qualified service
personnel who should refer to the table below. The
green/yellow wire shall be connected directly to the
units chassis.

WARNING: If the ground is defeated, certain fault con-
ditions in the unit or in the system to which it is con-
nected can result in full line voltage between chassis and
earth ground. Severe injury or death can then result if
the chassis and earth ground are touched simultaneously.

LIVE

E

NEUTRAL

EARTH GND

CONDUCTOR

L

N

BROWN

BLUE

GREEN/YEL

BLACK

Normal

Alt

WIRE COLOR

WHITE

GREEN

LITHIUM BATTERY WARNING

CAUTION!

This product may contain a lithium battery.
There is danger of explosion if the battery is
incorrectly replaced. Replace only with an
Eveready CR 2032 or equivalent. Make sure the
battery is installed with the correct polarity.
Discard used batteries according to manufactur-
er’s instructions.

ADVARSEL!

Lithiumbatteri - Eksplosjonsfare.Ved utskifting
benyttes kun batteri som anbefalt av apparatfab-
rikanten. Brukt batteri returneres appa-
ratleverandøren.

ADVARSEL!

Lithiumbatteri - Eksplosionsfare ved fejlagtig
håndtering. Udskiftning må kun ske med batteri
av samme fabrikat og type. Levér det brugte bat-
teri tilbage til leverandøren.

VAROITUS!

Paristo voi räjähtää, jos se on virheellisesti asen-
nettu.Vaihda paristo ainoastaan laitevalmistajan
suosittelemaan tyyppin. Hävitä käytetty paristo
valmistajan ohjeiden mukaisesti.

VARNING!

Explosionsfara vid felaktigt batteribyte. Använd
samma batterityp eller en ekvivalent typ som
rekommenderas av apparattillverkaren. Kassera
använt batteri enligt fabrikantens instruktion.

ELECTROMAGNETIC

COMPATIBILITY

This unit conforms to the Product
Specifications noted on the

Declaration of Conformity

.

Operation is subject to the following two
conditions:

• this device may not cause harmful

interference, and 

• this device must accept any inter-

ference received,including interfer-
ence that may cause undesired
operation.

Operation of this unit within significant
electromagnetic fields should be avoided.

• use only shielded interconnecting

cables.

IMPORTANT SAFETY INFORMATION

I

Содержание Artist RP300A

Страница 1: ...User s Guide...

Страница 2: ...who should refer to the table below The green yellow wire shall be connected directly to the units chassis WARNING If the ground is defeated certain fault con ditions in the unit or in the system to w...

Страница 3: ...ar ticularly at plugs convenience receptacles and the point where they exit from the apparatus Use only with the cart stand tripod bracket or table specified by the manufacture or sold with the appara...

Страница 4: ...obligation or liability in connection with the sale of this product In no event shall Digitech or its dealers be liable for special or consequential damages or from any delay in the performance of th...

Страница 5: ...o offer by going through this User s Guide with your RP300A in front of you It is your key to unlocking the full potential within the RP300A Included Items Before you get started please make sure that...

Страница 6: ...bs adjust the Parameter values listed directly above each knob for the selected effect When the Drum Machine is on these knobs control the Pattern Tempo and Level In Tuner mode these knobs are used to...

Страница 7: ...ct your instrument to this jack 2 Jam A Long Learn A Lick Jack Connect this jack to the headphone output of a tape or CD player in order to jam along with the music or to record a musical passage into...

Страница 8: ...r amp If connecting to a mixing console be sure to selecton one of the RP300A s Speaker Cabinet models See page 12 for more on using the Speaker Cabinet modeling Stereo Operation For stereo operation...

Страница 9: ...lume all the way down 2 Connect the plug of the PS0913B power supply to the Power Jack on the rear panel of the RP300A 3 Connect the other end of the PS0913B power supply to an AC outlet and turn the...

Страница 10: ...volume Bypass Mode The RP300A Presets can be bypassed for a clean unprocessed guitar tone To bypass the RP300A press both the Up and Down Footswitches simultaneously The Display will read Bypass indi...

Страница 11: ...speed Your interval choices include 1 4 3 8 1 2 5 8 3 4 7 8 and Full speeds 6 Pressing the Up Footswitch steps back through the loop at 1 second intervals 7 The Expression Pedal will control output le...

Страница 12: ...th the Matrix LEDs to choose the effect you wish to edit Successive presses of the Select button will advance to the next Effect in the Matrix 4 Use the 5 Knobs to change parameter values 5 Store your...

Страница 13: ...cter location Then repeat step 2 to select the desired alpha numeric character 4 Once the desired name is shown in the display press the Store button again to enter the second stage of the storing pro...

Страница 14: ...ds without having to change guitars during a performance Wah is an effect controlled by the Expression Pedal As the Expression Pedal is rocked back and forth it makes the guitar sound as if it is sayi...

Страница 15: ...p Level Cabinet Type Mic Position and EQ This allows you to switch from a clean to a distorted setting while retaining all other Effects settings Switching Amp channels is accomplished instantly with...

Страница 16: ...designed to close after every note depending on the Pluck Sensitivity This allows automatic volume swells to occur on a note for note basis Gate On Off The Number 1 Knob turns the Noise Gate on ON and...

Страница 17: ...thicker sound Parameter 1 The Number 2 Knob adjusts the rate Speed of the modulation Ranges from 1 to 99 Parameter 2 The Number 3 Knob adjusts the intensity Depth of the modulation Ranges from 1 to 9...

Страница 18: ...g the phase of the signal This means that when you begin to play the phaser may be at the any random point of the phase With a Triggered Phaser every time the signal exceeds the Sensitivity level sett...

Страница 19: ...Tech products The YaYa is controlled by the Expression Pedal and combines the characteristics of a wah and a flanger together providing a unique talk box type of effect As the Expression Pedal is rock...

Страница 20: ...g type of effect as if two guitars were playing the same part together Parameter 1 The Number 2 Knob adjusts the amount of pitch difference applied to the copied signal Ranges from 18 to 18 Mod Level...

Страница 21: ...ical environments It can provide the tight acoustics of a small room or the ambience of huge arena Reverb Type The Number 1 Knob selects the Type of Reverb or acoustic environment The RP300A provides...

Страница 22: ...nner SPEED Speed DEPTH Depth YaYa PEDAL Pedal DEPTH Depth RANGE Range Auto Ya SPEED Speed DEPTH Depth RANGE Range SynthTalk ATTACK Attack RELEAS Release VOX Vox SENSTV Sensitivity Envelope Filter AMOU...

Страница 23: ...ws 1 Press the Select button until the Expression row has been selected indicated by the LED lighting on the Expression row 2 Rotate the Number 1 Knob to select whether you want to assign LFO TR LFO T...

Страница 24: ...the Select button and press the Store button The display will read RESET indicating that the RP300A has reset the original factory set tings At this point the RP300A will automatically advance to the...

Страница 25: ...en showing DONE with the V Switch sensitivity value in the numeric Display and VSWTCHOn or VSWTCHOf depending on whether the V Switch is on or off You can audition the V Switch sensitivity by applying...

Страница 26: ...19 U A 39 U A 20 U A 40 James Fukai Evil D Dan Donegan Joey Z Dan Donegan Joey Z Jennifer Batten Metal Mike Chlasciak Jennifer Batten Metal Mike Chlasciak Mike Einziger Metal Mike Chlasciak Mike Einz...

Страница 27: ...Effects Pickup Simulator Wah Compressor Amp and Acoustic Guitar Models 3 band EQ Noise Gate Auto Swell Pluck Gate Cabinet Modeling Mic Placement Chorus Flange Triggered Flange Phaser Triggered Phaser...

Страница 28: ...ndy Parkway Sandy Utah 84070 USA PH 801 566 8800 FAX 801 566 7005 DigiTech and RP300A are trade marks of the Harman Music Group Inc Copyright the Harman Music Group Printed in the USA 02 2003 Manufact...

Отзывы: