DL-HD70 Owners Manual
9
Connect one end of a Category cable to the DL-HDE100 transmitter labeled
TWISTED PAIR
, then connect the
other end of the Category cable to the DL-HDE100 receiver labeled
TWISTED PAIR
HDBaseT Connection
TIA/EIA-568B
Orange/White
Orange
Green/White
Blue
Blue/White
Green
Brown/White
Brown
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
Pin 7
Pin 8
1
8
Twisted Pair Wiring
Use TIA/EIA-568B wiring for Category 6
connection between send and receive
units.
To ensure proper performance of the
DL-HDE100
, it is recommended that you use solid core, shielded Category 6 F/
UTP cabling at a minimum. Category 5e F/UTP may perform well up to a certain length but may not support power over
HDBaseT reliably longer distances.
For optimized performance use the following Liberty Wire and Cable branded cabling;
Category 6 plenum;
24-4P-P-L6SH
Category 6A plenum;
24-4P-P-L6ASH
Category 6 NON-plenum;
24-4P-L6SH
Category 6A NON -plenum;
24-4P-L6ASH
When using shielded category cabling
ALWAYS
...
....use shielded connectors
....properly ground the category cable
Connecting RS232 Control
RS232 Wiring
Connect the controller or device RX signal to
TX on the DL-HDE100 extender. Connect the
controller or device TX signal to RX on the
DL-HDE100 extender.
RS232 or serial control signals can be transmitted through the DL-HDE100 using the RS232 connection ports on
he DL-HDE100 transmitter and receiver.