6.1 Files – Record files(optional, for the models with SD card)
On “Files” menu scroll the button “ ” upward or downward to move the cursor to the
option “Record Files”, press the button “ ” to enter the “record files list”. Scroll the
the button “ ” upward or downward to move the cursor to select file to playback, a red
list indicates that the list has been selected, press the button “ ” to playback. During
playback scroll the button “ ” upward or downward, it will switch the current video to
the last file or the next file, and press the button “ ” again to exit.
Move the cursor to
the option “Return” and press “ ” to exit the current menu.
20141021 - 152413 0005
20141021 - 152403 0004
20141021 - 142957 0003
20141021 - 142911 0002
20141021 - 142651 0001
001 / 001
6.2 Files – Snapshot files(optional, for the models with SD card or built-in storage)
On “Files” menu scroll the button “ ” upward or downward to move the cursor to the
option “Snapshot Files”, press the button “ ” to enter the “snapshot files list”. Scroll the
the button “ ” upward or downward to move the cursor to select file to view, a red list
indicates that the list has been selected, press the button “ ” to playback. During
playback scroll the button “ ” upward or downward, it will switch the current picture to
the last file or the next file, and press the button “ ” again to exit. Move the cursor to
the option “Return” and press “ ” to exit the current menu.
20141021 - 152419 0010
20141021 - 152418 0009
20141021 - 152402 0008
20141021 - 152400 0007
20141021 - 143001 0006
20141021 - 142954 0005
20141021 - 142925 0004
20141021 - 142924 0003
20141021 - 142839 0002
20141021 - 142720 0001
001 / 002
Alarm
Instructions
Hang up
Be applicable to connect 2 normally closed (NC) or normally open (NO)
alarm inputs.
2 camera channels of alarm input without limitations on input type (can either
be the normally open type or the normally closed type).
ALM terminal of the alarm detector is connected in parallel with the ALM
terminal (The alarm detector shall be supplied by external power supply).
Ground terminal of the alarm detector is connected in parallel with the GND
terminal of the camera.
For NO alarm inputs, when the GND and ALM are in the connection state, it
will trigger the alarm.
For NC alarm inputs, when the GND and ALM are in the disconnect state, it
will trigger the alarm.
It applys to any alarm sens
or.
CAM1 and CAM2 of this production have each an alarm function. When the trigger
terminal and GND is shorted, the alarm is activate, the speaker of the indoor unit rings
and continues 120s, during this time, click “ ” to stop alarming and enter the
standby mode.
For the models with SD card, simultaneously, triggers recording or snapshotting
(related to the system settings). The recording time is 120s, during this time, click “ ”
to stop alarming and enter the standby mode.
Connection diagram:
Hang up
19
20
GND
DC12V
Video
ALM
CAM
GND
ALM
AC/DC
power
adapter
for
camera(not included)
Содержание VID
Страница 1: ......
Страница 2: ...1 2 3 5 7 8 9 10 11 11 12 11 13 5 7 8 9 10 11 11 12 11 13...
Страница 3: ...7 11 13 5 5 7 8 9 10 11 11 12 11 13...
Страница 4: ...DESCRIPTION ON SYMBOL Hang up Unlock Monitoring Setting Talk...
Страница 6: ...Hang up Talk...
Страница 7: ...Talk Monitoring Monitoring Monitoring Monitoring Monitoring Hang up Hang up Hang up Unlock...
Страница 13: ......