Setting of unlock delay time
System applies 5 sec
unlock delay time by default. Upon a necessity this time could be prolonged or reduced
(1 sec – 100 sec). Pay attention that too long delay time could damage some type of electronic bolt openers. See
an example of setting 10 sec delay time:
[3.SEttinGS]
>
>
[1.Lc.dELAY]
>
>
[t- ]
> (enter t=10) >
>
[donE]
– setting 10 sec
delay time
Selection of a lock type
Door phone DD-5100 allows to manage locks of two types ( Fig. 18): 1. NC – locks, connected to normally
closed circuit, i.e. locks with a permanent power supply, paused only when unlocking (electromagnetic lock); 2. NO
- locks, connected to normally opened circuit, i.e. power supply is used only when unlocking (electric bolt).
Fig. 18: Settings of lock type
The first type - NC (electromagnetic lock) is set by default. For changing of the setting choose an appropriate
lock type ( 1.NC or 2.NO). See an example, how to set an outlet of lock management for bolt type lock.
[3.SEttinGS]
>
>
[1.Lc.tYPE]
>
>
[2.no]
>
>
[donE]
Access control settings
Access control settings allow to limit ways of external door unlock. All access control types are allowed by
default (fig. 19), i.e. using TM/RFID identificator or entering door unlock code. However, external door unlock could
be forbidden totally upon a necessity. Doors could be opened only by an internal unlock button or during
conversation with a guest, using audio receiver. You could set one entrance control type or combine several ones.
In order to ensure safety, residents often want to refuse using codes that could be learned by friends of
residents or the third parties. In this case set an access control type, allowing to unlock doors externally only using
TM/RFID identificator. For system configuration perform the following:
1) disable access using code:
[3.SEttinGS] >
> [3.Acc.tYPE] >
> [1.CodE] >
> [1.diS] >
> [donE]
2) enable access using code:
[3.SEttinGS] >
> [3.Acc.tYPE] >
> [1.CodE] >
> [2. En] >
> [donE]
3) disable access using TM tag:
[3.SEttinGS] >
> [3.Acc.tYPE] >
> [1.t.tAG] >
> [1.diS] >
> [donE]
25
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
ENTER
Fig. 19: Entrance control types
[1.CodE]
– door unlock usign user PIN
[2.t.tAG]
– door unlock using TM tag
[3.r.tAG]
– door unlock using RFID tag
[3.SEttinGS]
[3.Acc.tYPE]
Fig. 17: Structure of System settings
ENTER
ENTER
ENTER
ENTER
[3.SEttinGS]
[2.Lc.tYPE]
[1.nc]
– normal closed (electromagnetic lock)
[2.no]
– normal open (electric bolt)
ENTER
ENTER
ENTER
ENTER
ENTER
[3.SEttinGS]
– system settings
[1.Lc.dELAY]
– setting of unlock delay time
[2.Lc.tYPE]
– selection of lock type
[3.Acc.tYPE]
– access control settings
[4.Err.UnL.]
- door unlock timer if error
[5.CS.no.]
- call signal number (1-15)
[6.UnL.bEEp.]
- Unlock Signal in handset ON / OFF