Installation Step 3
–
Powering the AIS WI-FI GATEWAY
Provide power connections to the unit. Power is connected to the
four core PWR/DATA cable on the Red and Black wires. Red wire is
the positive (+) connection, Black wire is the negative (-) connection.
Connect the stripped wires to the nearest source of primary 12V or
24V DC power. Ensure that the supply is connected via a 1A fuse
(not supplied) or suitable circuit breaker. The fuse should be fitted
in the positive power connection to the unit if necessary.
Apply power to the AIS WI-FI
GATEWAY and you should
see the three LEDs start to
illuminate or flash. The
following table shows what
each LED indicates;
Condition
Red LED
Yellow LED
Green LED
Flashing
No wireless connection
Data
UDP Connection
ON
TCP Connection
OFF
Wireless device connected
No Data
No Power
Turn off the AIS WI-FI GATEWAY and continue with the NMEA
interfacing.