Digital Watchdog STAR-LIGHT DWC-V6263WTIR Скачать руководство пользователя страница 11

Installation-

Instructions

1

Detach the camera’s cover dome from the 

camera’s module by unscrewing the four cover 

dome screws using the Torx Wrench. 

2

Use the camera or mounting template to mark 

and drill the necessary holes in the wall or ceiling.  

3

Pull wires through and make connections.

4

5

Using four included screws, mount and 

secure the camera to the wall or ceiling. 

Secure the camera’s cover dome onto the 

camera base and remove the protecting film to 

complete the installation.   

11

Содержание STAR-LIGHT DWC-V6263WTIR

Страница 1: ...al Ver 08 17 Before installing and using the camera please read this manual carefully Be sure to keep it handy for future reference STAR LIGHT Universal HD over CoaxTM Indoor Outdoor Dome Cameras DWC...

Страница 2: ...ecting to Monitors Control Board Adjusting the Camera angle 11 13 14 15 OSD MENU Menu Tree OSD Menu Exposure OSD Menu Color OSD Menu Day Night OSD Menu Function OSD Menu Motion OSD Menu Privacy OSD Me...

Страница 3: ...e product 2 Incorrectly connecting the power supply or replacing battery may cause explosion fire electric shock or damage to the product 3 Do not connect multiple cameras to a single adapter Exceedin...

Страница 4: ...all other parts are properly connected While operating if any abnormal condition or malfunction is observed stop using the camera immediately and contact your dealer Handling Do not disassemble or tam...

Страница 5: ...ded for ventilation to ensure reliable operation of the product and to protect it from over heating The openings should never be blocked by placing the product on bed sofa rug or other similar surface...

Страница 6: ...ronic products should be disposed of separately form the municipal waste stream stream in accordance to laws designated by the government or the local authorities 3 The correct disposal of your old ap...

Страница 7: ...ng Repels Water Dust and Grease 100 Smart IR with Intelligent Camera Sync Smart DNR 3D Digital Noise Reduction True Day Night Mechanical IR Cut Filter De Fog Extreme Weather Image Compensation Highlig...

Страница 8: ...485 UTP Alarm Output Power Cable BNC Cable Part name Lens Light Sensor Bottom Case Side Port for Cabling IR LED Dome Cover Upper Case Cover screws Tilt Stopper Screw OSD Joystick Controller Test Video...

Страница 9: ...Dimension Unit Inches mm 5 7 145mm 1 85 47 0mm 2 43 61 8mm 9...

Страница 10: ...deo Cable is used to test the camera by connecting to a portable display Please check if all the camera and accessories are included in the package Camera Manual Template Sheet Screw Plastic Anchor 4p...

Страница 11: ...ench 2 Use the camera or mounting template to mark and drill the necessary holes in the wall or ceiling 3 Pull wires through and make connections 4 5 Using four included screws mount and secure the ca...

Страница 12: ...de 12VDC 24VAC Monitor Test Video Output UNIVERSAL DVR UTP COAX Power Connection 12VDC 24VAC Dual Voltage Auto Polarity Detection and Protection All cameras are equipped with a test video output for o...

Страница 13: ...Output UNIVERSAL DVR Power Connection 12VDC 24VAC Dual Voltage Auto Polarity Detection and Protection All cameras are equipped with a test video output for on site configuration Note When switching to...

Страница 14: ...White Alarm Output Cable Cable to output Motion Detection signal OSD Joystick The function setting and video output can be adjusted with OSD joystick default HD A Image Mode Switches to HD TVI mode wh...

Страница 15: ...e lens by its axis is called Rotation Panning 360 Rotation 360 Tilting 70 Adjusting the camera angle Adjusting the camera lens To adjust the field of view turn the zoom screw counter clockwise and mov...

Страница 16: ...LL COMP USER 50Hz 60Hz ENG CHN CHN S JPN KOR OFF ON COMMUNICA CAM TITLE IMAGE RANGE FREQ LANGUAGE INITIAL EXIT JUMP OFF ON 0 15 OFF ON 0 59 0 33 0 60 0 34 0 20 0 20 0 20 0 3 PRIVACY ZONE NUM ZONE DISP...

Страница 17: ...talled in an outdoor environment Select FLC if the camera is experiencing some flickering in the image The shutter speed will be set to 1 100 for NTSC or 1 120 for PAL If Manual is selected set the sh...

Страница 18: ...r right The higher the number the zone will move to the right V POS Move the Zone position up or down The higher the number the zone will move down H Size Reset the zone s size horizontally The higher...

Страница 19: ...AUTO to have the WDR and DRC levels adjusted automatically Set the DEFOG level from LOW MIDDLE HIGH DEFOG 0 10 AGC enhances the picture brightness in low light conditions A higher level AGC setting m...

Страница 20: ...changes lower than 2500K and tigher than 12000K PRESET Preset fixes the white balance based on the current lighting automatically MANUAL Users can control the white balance manually by changing RED G...

Страница 21: ...mera is installed If the margin is too low the camera will switch from color to B W and back WITH LED CDS Threshold Marks the light level at which the camera will switch between color and B W The lowe...

Страница 22: ...3 4 0 10 Sets the image sharpness The higher the number the sharper the image GAMMA 2 0 45 0 75 Select the desired gamma level 0 55 is default setting MIRROR FLIP 3 OFF MIRROR Reflects the camera hori...

Страница 23: ...tone color available 3 MDRECT FILL Color setting for operating motion zone 4 To use the motion detection settings be fore Motion is ON TEXT ALARM 6 7 Setup a text to appear on the screen when motion i...

Страница 24: ...mber the zone will move down H SIZE Reset the zone s size horizontally The higher the number the right side panel will move further to the right V SIZE Reset the zone s size vertically The higher the...

Страница 25: ...om the following options 2400 4800 9600 57600 115200 bps SET DONE Set the value of CAM ID and BAUDRATE 2 CAM TITLE Add a name to the camera Set the title by using the OSD joystick IMAGE RANGE Image Ra...

Страница 26: ...Select from the following English Default Chinese Chinese S Japanese and Koran 6 INITIAL Reset the camera to its default settings Press and hold the select button for five 5 seconds OSD Menu_Setup COM...

Страница 27: ...1 2 SAVE EXIT 1 Exit the OSD menu after saving the recent changes Exit the OSD menu without saving any changes EXIT 2 OSD Menu_EXIT SAVE EXIT EXIT EXIT EXPO MOTI PRIV RGB D N FUNC SET EXIT 27...

Страница 28: ...urely Check the power supply and make sure the camera has the proper voltage and current Check UTP COAX switch inside the camera s housing and confirm the switch s position matches the signal connecti...

Страница 29: ...ft Image Sensor 1 3 CMOS Sensors Active Pixels 1944 H x 1092 V Scanning System Progressive scan 60Hz 50Hz Signal Technology Freguency 2 0 Megapixel Universal Internal Resolution Synchronization 1920x1...

Страница 30: ...o more than 90 Non Condensing IP Rating IP66 Other Certifications FCC CE ROHS Housing Material and Dimensions Aluminum 5 7 x 4 28 in 145 x 108 8mm Weight 1 65 lbs Digital Noise Reduction OFF LOW MIDDL...

Страница 31: ...low the exclusion or limitation of incidental or consequential damages or limitations on how long an implied warranty lasts so the exclusions or limitations listed above may not apply to you This warr...

Страница 32: ...Friday from 9 00AM to 8 00PM Eastern Standard Time A purchase receipt or other proof of the original purchase date is required before warranty service is rendered This warranty only covers failures d...

Страница 33: ...Notes 33...

Страница 34: ...Notes 34...

Страница 35: ...Notes 35...

Страница 36: ...st Headquarters Office 16220 Bloomfield Ave Cerritos CA 90703 PH 866 446 35951 FAX 813 888 9262 www Digital Watchdog com Technical Support USA Canada 1 866 446 3595 International 1 813 888 9555 French...

Отзывы: