DIP Switch Setup
Installation -
2
2. Communication Baud Rate Setup
Select the appropriate baud rate with DIP switch combination.
4. Camera ID Setup
ID number of camera is set using binary number.
The example is shown below.
Inner Box
1
2
3
4
5
ON
8J
2
1
3
4
5
6
7
8
2400 BPS -
Factory Default
ON
8J
2
1
3
4
5
6
7
8
4800 BPS
ON
8J
2
1
3
4
5
6
7
8
9600 BPS
ON
8J
2
1
3
4
5
6
7
8
19200 BPS
38400 BPS
ON
8J
2
1
3
4
5
6
7
8
3. RS-485 Termination Resistor
- Pin 8 is used to control RS-485 termination.
- Normally, it must be set to OFF state.
- When you have trouble with long daisy chain style
connection, turn ON this termination switch for the last camera.
ON
8J
2
1
3
4
5
6
7
8
Pin
1
2
3
4
5
6
7
8
1
2
4
8
16
32
64
128
ID Value
ex) ID=5
ex) ID=10
ON
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
- If you want to control the camera with another device, you
must match the Camera ID with CAM ID, setting on DVR or
the keyboard controller.
- ID number of the camera is set using binary number.
- The range of ID is 0~255.
- Factory default of camera ID is 1.