ASSEMBLY NOTES
This controller is designed for monitor and custom display projects using 4096x2160 resolution with V-by-One interface, eDP interface
or LVDS TFT panels. The following provides some guidelines for installation and preparation of a finished display solution.
Preparation
: Before proceeding it is important to familiarize yourself with the parts making up the system and the various connectors,
mounting holes and general layout of the controller. As much as possible connectors have been labeled. Guides to connectors and
mounting holes are shown in the following relevant sections.
1.
LCD Panel
: This controller is designed for typical V-by-One (8 lanes), eDP (HBR/HBR2) and LVDS interfaced panels with panel
voltage 3.3V, 5V, 10V, 12V or 18V, External for 10V, 12V and 18V interface. Due to the variation between manufacturers of
panels signal timing and other panel
characteristics, factory setup and confirmation should be obtained before connecting to a
panel.
(NOTE: Check panel power jumper settings before connection)
2.
LCD Controller
: Handle the controller with care as static charge may damage electronic components. Make sure correct jumper
to match the target LCD panel.
3.
Panel cable
: In order to provide a clean signal it is recommended that all panel cables (V-by-One signal, eDP and LVDS) supplied
by Digital View. Care should be taken when placing the cables to avoid signal interference.
4.
Inverter/Backlight driver
: This will be required for the backlight of an LCD, some LCD panels have an inverter/backlight driver
built in. As LCD panels may have 1 or more backlight tubes and the power requirements for different panel backlights may vary it
is important to match the inverter/backlight driver in order to obtain optimum performance. See Application notes page 28 for
more information on connection.
5.
Inverter/backlight cables
: Different inverter/backlight models require different cables and different pin assignment. Make sure
correct cable pin out to match the inverter/backlight. Using wrong cable pin out may damage the inverter/backlight.
6.
Function Controls
: The following section discusses the controls required and the section on connectors provides the detail. The
controls are minimal: On/Off, Backlight Brightness (depends on inverter), OSD (5 momentary buttons) analog VR type or (8
momentary buttons) digital type.
7.
Function controls cable:
The cables to the function switches should be of suitable quality and length so that impedance does
not affect performance. Generally lengths up to 1 meter (3 feet) should be acceptable.
8.
Optional LED
: The pin direction of the LED should be corrected for right color indication. Red color stands for standby. Green
colors stands for signal on. The status LED is an optional part only, can be unconnected.
9.
Optional IR sensor
: It is an optional part only, can be unconnected if not using IR remote control.
10. RS-232 control interface :
Serial control via this interface port.
11. External panel power output
: User for specific panel model.
12. Panel control signal :
Use for specific panel model.
13. SPDIF Audio output :
This port support SPDIF audio output from the HDMI / Display Port audio source inputted.
14. Ambient light sensor connection :
3 ways connector provides interface for ambient light sensor connection by using Kit 70220-3.
15. Backlight status input :
2 ways connector provides interface for connection with the specific panel type which support the panel
with backlight status monitoring function.
16. On board LED backlight driver :
The on board LED driver supports 4 LED strings max 50V total LED backlight via J10
connector.
17. DVI-I input cable :
Plug the DVI cable to the connector P1 on the controller board.
18. HDMI input :
Plug the HDMI cable to the connector P2(HDMI 1.4) / P3(HDMI 1.4) / P4(HDMI 2.0) on the controller board. This
port is not supported when CN5/CN16 are connected.
19. Alternate HDMI input :
This port gives alternate HDMI input support.
20. Alternate DVI-I input :
This port gives alternate DVI-I input support.
21. Control over network connection :
This is a network device that allow to control RS-232 enable devices over a TCP/IP based
Ethernet and the Internet using a web browser. Please refer to Appendix V in details.
22. Reserved for Audio adaptor board P/N 416940020-3:
The audio add-on board gives the audio input and output signal
connection. It is an optional and reserved part only, can be unconnected if not using audio. It requires an audio cable P/N
426451800-3 to connect SVX-4096 (CN14) to the Audio Add-on Board (CN2).
CAUTION : The Audio Add-on Board P/N 416940020-3 can only operate with 12VDC power input environment.