4
english
NO IMAGE
No connection:
Check if all connections are properly made.
Source off:
Check if the equipment is powered on.
Lamp dead:
The lamp may need replacement. Check the LAMP TIME in the UTILITIES sub
menu.
Source hibernated:
Engage the source to display and activate image.
Notebook external screen:
Different notebook PC’s use different combinations of keystrokes
to enable the external graphics port.
No lens:
Check if lens is attached properly.
Shutter engaged:
Check if the shutter is engaged.
Lens cap:
check if the lens cap is off!
DARK IMAGE
Old, worn lamp:
The lamp may need replacement. Check the LAMP TIME in the LCD.
Low BRIGHTNESS and CONTRAST settings:
Press AUTO or use the menu system, PICTURE
sub menu for CONTRAST and BRIGHTNESS adjustment.
FLICKERING IMAGE
Bad lamp:
Replace the lamp. Check the LAMP TIME in the LCD.
UNSHARP IMAGE
Keystone correction may have been activated inadvertently, compressing parts of the image that
affect the display of fine-line graphics, text and other images of high resolution.
Source resolution is different from projectors native resolution:
The projector will automatically scale and resize the input format to its native resolution.
Use a different scaling factor in the PICTURE sub menu, ASPECT. You may also adjust the
SHARPNESS.