background image

Arming and Disarming 

Graphic Touchscreen Keypad User’s Guide 

11

For an Area System the Keypad screen displays 

SYSTEM ON

 if 

at least one area in the system is armed, followed by the area 

numbers that were armed. The Keypad screen displays 

ALL SYSTEM 

ON

 if all areas in the system are armed.

Exit Delay:

 The screen then displays the exit delay time as it counts 

down. If the entire system has been armed, your system beeps the 

exit delay tone at eight-second intervals until the last 10 seconds 

when the keypad beeps at three second intervals. After exiting the 

building, if you re-enter during the countdown the exit countdown 

restarts, allowing additional time to then disarm or again exit the 

building during the countdown. This restart can occur only one 

time. When the exit delay time expires, zones are armed. If your 

system uses a keyswitch to arm an area, the exit delay time does 

NOT count down on the screen display.
When you arm both the 

Perimeter

 and 

Interior

 to leave the 

building but then you do not exit by the time the exit delay ends, 

the system automatically arms but the interior area(s) remain 

disarmed because you have not exited.
I

nstant:

 During the exit delay time, you can cancel the exit 

and entry delays and cause all zones to be instant zones. 

Press 

ARM

 

INSTANT 

while the exit delay displays. This immediately 

arms the exit zones. However, no entry delay is provided and an 

alarm immediately occurs should an entry door be opened.

ONE MOMENT . . . Message:

 If your system is monitored, it may 

be programmed to wait for the arming report to be sent to the 

monitoring station before displaying the armed message. This 

verifies that the arming message was received by your monitoring 

station. While the system waits, the screen displays 

ONE MOMENT....

 

When the report is received, the keypad buzzes for one second 

and displays the armed message. If the report is not received, the 

screen displays 

LOCAL ALARM ONLY 

before displaying the armed 

message.

Key Fob Arming

Press the key fob button programmed for 

Arming

 or 

Toggle (Arm/

Disarm)

 button. A 

Red LED

 two-second acknowledgement indicates 

All System On

. A 

Green/Red

 two second acknowledgement 

indicates 

System On

 with some areas armed.

Key Fob Disarming

Press the key fob button programmed for 

Disarming

 or 

Toggle 

(Arm/Disarm)

 button. A 

Green LED

 two-second acknowledgement 

indicates 

All System Off

.

Содержание GRAPHIC TOUCHSCREEN KEYPAD

Страница 1: ...U S E R S G U I D E GRAPHIC TOUCHSCREEN KEYPAD NOW 90 SAT 71 Reset...

Страница 2: ...HIS A FALSE ALARM displays If a burglar alarm is valid press NO to send an alarm verification message to the Central Station If a valid alarm has not occurred press YES to cancel the alarm and send an...

Страница 3: ...stant Zone 8 24 Hour Zone 8 Areas 8 Central Station Monitoring 8 Status 8 Status List 8 Zone Status 9 Armed Status 9 Exit Error 9 Arming and Disarming 10 How Your System Operates 10 Arming Functions 1...

Страница 4: ...rmation on your system Graphic Touchscreen Keypad Main Screen Your system has an easy to use Graphic Touchscreen Keypad that allows you to operate the system When accessing any other screens you may r...

Страница 5: ...easy to understand arming options screen When leaving in a hurry press the shield until it glows the system quick arms the Away system and starts the exit timer giving you ample time to leave Once you...

Страница 6: ...tus Blue Steady Panel Disarmed AC Power OK Battery OK Blue Blinking Panel Disarmed AC Power OK Battery Fault No Light Panel Disarmed AC Power Fault Battery OK Red Steady Panel Armed AC Power OK Batter...

Страница 7: ...creen prompting entry of a USER CODE Enter your user code to send a Check in Report 3 Chime Press CHIME until it glows This activates MONITOR The System Status displays MONITOR ON in the upper right c...

Страница 8: ...needing to disarm and rearm the system 6 Keypad Pressing KEYPAD until it glows displays the Keypad screen This replicates the standard button type keypad Scroll through the User Menu by pressing CMD R...

Страница 9: ...en seconds prior to the end of the countdown the rate of pulsing increases Monitor Chime A tone that sounds each time a door or window is opened while you are using the Zone Monitor Chime option from...

Страница 10: ...el signal is sent to the Central Station ALARM VERIFIED A valid burglar alarm has occurred and has been manually verified by the user The alarm system also transmits a VERIFY message to the Central St...

Страница 11: ...causes the panel to start the entry delay time During the entry delay time enter a valid user code to disarm the system or an alarm occurs Instant Zone Exterior windows and non entry doors or interio...

Страница 12: ...n of areas within your security system The screen displays When HOME SYSTEM ON The perimeter areas is armed in a Home Away system PERIMETER ON The perimeter is armed in an All Perimeter system ALL SYS...

Страница 13: ...selected areas are arming For Home Away or Home Sleep Away systems the Keypad screen displays ALL SYSTEM ON if all areas in the system are arming HOME SYSTEM ON or SLEEP SYSTEM ON if only selected ar...

Страница 14: ...rms but the interior area s remain disarmed because you have not exited Instant During the exit delay time you can cancel the exit and entry delays and cause all zones to be instant zones Press ARM IN...

Страница 15: ...if at least one area in the system is armed and ALL SYSTEM ON if all areas in the system are armed 6 The screen then displays the exit time in seconds and counts down the remaining time EXIT seconds...

Страница 16: ...is pressed If a valid user code is not entered within 5 seconds or an invalid user code is entered the prewarn tone begins sounding again 2 ALL SYSTEM OFF is displayed in the upper right corner after...

Страница 17: ...to send an alarm verify message to the Central Station System Arming Area Systems Your security system is programmed into separate areas Youmayarmanddisarmallareasatonetimeoreachareaindividually You...

Страница 18: ...to bypass the zone s before arming 7d Select STOP to stop the system from arming Correct the zone problem s and return to step 1 Note 24 hour zones cannot be bypassed 8 The screen displays SYSTEM ON i...

Страница 19: ...ess appear in the display For example AREAS 2 4 To remove an area number from the display press the corresponding number on the screen Press CMD when done 6 After all areas have displayed any alarms t...

Страница 20: ...sarming sequence is the same as Area Disarming steps 2 through 6 in the previous section 2 The screen may display ALARM CANCELLED if your system was disarmed after alarm message had been sent to the c...

Страница 21: ...those functions to which you have access are displayed Please refer to the user guide provided with your control panel for complete list and operation of the user menu Accessing the User Menu 1 Press...

Страница 22: ...tery is either low or missing Contact your service person System Trouble or Service Required Yes There is a problem with one or more components in the system Contact your service person System Busy No...

Страница 23: ...tone 6 F Fire alert 6 H Home Sleep Away 2 10 12 14 I Instant Zone 8 Interactive Shield 1 2 12 13 14 Interior 10 11 K keypad 1 3 5 6 7 8 11 12 13 14 15 18 L LED 1 3 M Main Screen 1 2 3 4 5 12 13 14 16...

Страница 24: ...Graphic Touchscreen Keypad User s Guide 21...

Страница 25: ...LT 1191 1 01 13245...

Отзывы: