5
RLE
Open Area Application (manufacturing, storage, loading dock)
Fixture
Optic
Light Bar Setting
RLE-D1
WIDE
0°, 0°, 0°, 0°
RLE-H1/P1
WIDE
0°, 0°, 0°, 0°
Highbay / Racked Application
Fixture
Optic
Light Bar Setting
RLE-D1
NARROW
-10°, 10°
RLE-H1/P1
NARROW
-20°, 0°, 20°
Highbay / Racked Application (widely-spaced fixtures)
Fixture
Optic
Light Bar Setting
RLE-D1
NARROW
-20°, 20°
RLE-H1/P1
NARROW
-30°, 0°, 30°
0°
0°
0°
RLE-D1
RLE-H1/P1
0°
0°
0°
Example 1
RLE-D1
RLE-H1/P1
-10°
10°
-20°
0°
20°
0°
Example 2
-20°
20°
-30°
0°
30°
RLE-D1
RLE-H1/P1
0°
Example 3
Appendix B: Lightbar Examples