Digital Loggers Web Power Switch 7 Скачать руководство пользователя страница 17

Ethernet Power Controller 7

17

Specifications

 

Alert Beeper 

73dBa at 12” Programmable

Applications 

Test equipment, industrial, datacenter 

  

 power control and reboot. Indoor use only.

Circuit Breakers 

Manual reset, 15A Thermal, UL Supplemental

Clock / RTC 

15 year Li battery

Controls / Display 

Reset -to-factory-default switch, 2x16 Backlit LCD  

 

w/ PowerSave, 5 button keypad, E-Stop

Enclosure 

Steel, double grounded.  Vented 4 sides  Fanless

Environmental Port 

RJ-12.  Suitable for DHT/SHT series sensors

Ethernet Interface 

10/100 autosensing, Static IP, TCP port selectable,  

 

8 pin RJ-45 w/ internal FCC filtering

FCC Testing 

Part 15  FCC ID 2ACIUEPCR5

Humidity 

8-80% RH Operating

Input Power Cord 

Fixed 14AWG with 5-15 plug standard 120VC only

Inlet and Outlet Rating  UL, CSA 15A, 120VAC only
Input Frequency 

 Power supply - DC-400Hz

Metering Accuracy 

+/- 2V, +/- .5A when calibrated at 50-60Hz only

Operating Temperature  -30º to 170ºF, -34º to 77ºC
Options - Factory 

Input cord length and 120V plug style

Power Supply Rating 

90-240V, AC/DC Autosensing

Password Transmission  Encrypted, base 64 or HTTPS
Power Dissipation 

5.3W Typ Max (all on, battery charging) <3 W idle

Power Fail Hold-Over 

350ms minimum (all relays on) 

Power-Up Modes 

Last used settings, all power on or off, sequential 

 

on or run user-script ~30s after power-up

Relay Contact Spec 

 15-25A AC/DC, 1/2HP

Surge Protection  

Dual 3600WMetal Oxide Varistors

Size  

3.5x5.5x19”  8.9x14x48cm 2-U

Weight (packed) 

Single unit 10.3lbs  4.7kg

WiFi 

Atheros 9331 2.4G 802.11n RP-SMA - FCC Note: 

 

The EPCR5 may only be used with (1) the manu- 

 

facturer supplied antenna (Gain: 2.0dBi), or (2) a 

 

50 Ohm antenna of equal or lesser gain

Содержание Web Power Switch 7

Страница 1: ...USER S GUIDE Ethernet Power Controller 7...

Страница 2: ...s are spaced for plugs and adapters Un switched outlets are provided for always on devices Switched outlets are metered in two banks Unswitched outlets are unmetered Programmable LCD Display and Keypa...

Страница 3: ...on expansion port E mail SNMP and Jabber notification improved power metering a light sensor internal temperature sensor RS 232 for future expansion extended battery life HTTPS WiFi support web power...

Страница 4: ...that a network connection is established If you don t receive a response proceed to the IP Setup section below Log in to the power controller using the default user name admin and the password 1234 No...

Страница 5: ...ion and select Properties Proceed to step 2 Windows Vista Open Start right click on Network then on Properties Double click Network and Sharing Center click Manage Newtork Connections A Network Connec...

Страница 6: ...browser to 192 168 0 100 Log in Detailed instructions are at digital loggers com ip_setup Max OS X Turn AirPort off temporarily Click the Apple logo then System Preferences then Network Select Built...

Страница 7: ...es 192 168 0 must match the IP on your computer to access the controller Using a Ping utility is a good way to confirm a valid network configuration An unreachable report from Ping indicates a misconf...

Страница 8: ...ited access to outlets as assigned by the administrator Outlet Control Clicking Outlet Control links to the home page used for manually switching outlets on and off Access to specific outlets is deter...

Страница 9: ...nal event log including logins outlet switching power interruptions and AutoPing events Recent events are stored in the log and accessible from the System Log page SYSLOG export is supported For more...

Страница 10: ...age An adjustable ON sequence delay takes effect when outlets are turned on one after another either when using the All Outlets On button on power up or when switching manually using the front panel T...

Страница 11: ...the status screen Wrong Password Lockout After three failed login attempts the switch can disable access for a selected period of time 0 60 minutes Power Loss Recovery Modes The power loss recovery mo...

Страница 12: ...teway must be entered in this section When changing IPs you may need to restart your network switch to validate the new IP on an auto configuring switch port Be sure to record the new IP address Use t...

Страница 13: ...rebooted Since occasional network timeouts and packet loss can occur during normal Ethernet operation between 5 and 10 pings is suggested Times to Attempt Reboot If you have an unreliable target devic...

Страница 14: ...etwork connectivity We connect the router to outlet 1 enter the external IP on the left and leave all timing values at defaults Internet Access Like to access your power controller over the Internet L...

Страница 15: ...placed after 5 years of use Lua Scripting The controller can be customized using the Lua language A full description is beyond the scope of this manual Please visit digital loggers com Lua html RESTfu...

Страница 16: ...oltage and low voltage shutdown are provided on the safety shudown page Take care when configuring the E Breaker so as not to create an oscillation Open Source Code In compliance with the spirit of th...

Страница 17: ...d 120VC only Inlet and Outlet Rating UL CSA 15A 120VAC only Input Frequency Power supply DC 400Hz Metering Accuracy 2V 5A when calibrated at 50 60Hz only Operating Temperature 30 to 170 F 34 to 77 C O...

Страница 18: ...days from date of issue This warranty does not cover products which are modified including firmware modifications subjected to rough handling or used in applications for which they were not originally...

Страница 19: ...Ethernet Power Controller 7 19 Related Products Call 408 330 5599 Smart PoE Injectors 90 240VAC Smart PDU DIN Power relay with WiFi 2x50A High Power Switch 12 72VDCi...

Страница 20: ...2695 Walsh Ave Santa Clara CA 95051 408 330 5599 digital loggers com...

Отзывы: