Web Power Switch 6

www.digital-loggers.com

Web Power Switch 6

9

8

Logout

Logout ends the web session immediately. A login is required to 

reconnect. Browser authentication will time-out automatically after 

several minutes of inactivity.

Programmable Web Links

Four additional user-defined web links are provided on the outlet 

control page. Factory defaults are 

Manual, FAQ,

 etc. You may 

change the name and destination URL for these links on the 

Settings

 page. These links are convenient for connecting to other 

power controllers or to remote sites.

switching Outlets On and Off

The outlet control page lets you control any pair of outlets (except 

the always-on pair). A master setting also allows users (with 

security access) to switch all outlets on or off. 
To switch an outlet on or off, simply click to the right of the outlet 

name or number. Switching is immediate.
Use the keypad for local switching: Select an outlet using the 

arrow keys, then press on, off, or cycle. Press ON or OFF for 5 

seconds to lock or unlock an outlet.

 

You may also 

Cycle

 a device which is connected to the controller. 

This feature is useful for rebooting Ethernet devices which may 

interrupt the web link to the controller. Clicking 

Cycle

 switches 

power off, waits a few seconds (as specified on the setup page), 

and then switches power back on.  This resets the attached 

device. You may also cycle all outlets using the 

Cycle All Outlets

 

button on the bottom of the page.
Depending on your web browser settings, you may need to click 

the Refresh button or F5 key to update the on-screen status 

display after changing settings. Screen refresh rate is adjusted on 

the 

Setup

 page.

setup Page

The 

Setup

 page allows the administrator to configure the power 

controller.  These settings are supported:

Controller and Outlet Names

Use the controller name fields to assign a Controller Name to the 

power controller itself.  Examples are “Server Rack 4 PDU” or 

“Reactor Coolant Pumps”. The Controller Name field appears on 

the top of the home page. Assign a separate name to each outlet, 

such as “Customer 4” or “Email Server” to aid identification.

Power-On Sequence Delay

When a time value is entered in the “All ON Sequence Delay” 

field, the power controller will pause for a period of time before 

switching each outlet on in sequence. This delay helps prevent the 

power surges and blown circuit breakers which can occur when 

multiple devices are switched on simultaneously. A delay of 60 

seconds is suggested for server applications.

You may also enter a screen refresh delay in this section.  If 

“Enable screen refresh” is checked, and a delay value is entered, 

your browser should periodically update the status screen.

Wrong Password Lockout

After three failed login attempts, the switch can disable access for 

a selected period of time (0-60 Minutes).

Power Loss Recovery Modes

The power loss recovery mode setting has three settings which

take effect after a power failure:

1.  You can turn all outlets off (all systems will be switched off 

until manually turned on later) by checking the first box. 

2.  You can automatically turn all outlets on using the “All ON 

sequence delay” described above.  Check the second 

option to do this.

3.  You can return to the same outlet settings that were used 

prior to the power loss. The “All ON sequence delay” will 

Содержание Web Power Switch 6

Страница 1: ...User s Guide Web Power Switch 6...

Страница 2: ...t access to the power controller The administrator selects which outlets each user controls Sequenced On Timer A programmable delay timer allows outlets to be switched on in sequence rather than simul...

Страница 3: ...to a switch you may need to cycle power to the switch to establish a connection 4 Ping the default address http 192 168 0 100 to confirm that a reliable network connection is established If you don t...

Страница 4: ...nual Since features are subject to change without notice this manual may not be an exact match for earlier controllers and earlier firmware versions Find the firmware revision history here Windows 7 V...

Страница 5: ...e on screen status display after changing settings Screen refresh rate is adjusted on the Setup page Setup Page The Setup page allows the administrator to configure the power controller These settings...

Страница 6: ...pecify the address of an IP device you wish to monitor After entering the IP address the settings page will refresh and you can select the outlets associated with this address Use the checkboxes in th...

Страница 7: ...com Since we re constantly adding and changing features specifications are subject to change without notice Specifications ETHERNET POWER CONTROLLER II 13 Specifications Operating input voltage and po...

Страница 8: ...d by technical support RMA material must be shipped prepaid to DLI RMA numbers are valid for 15 days from date of issue This warranty does not cover products modified subjected to rough handling or us...

Страница 9: ...2695 Walsh Avenue Santa Clara CA 95051 Tel 408 330 5599 Fax 408 541 8459 www digital loggers com AutoPing Function Online Manual Scheduling Function Product Suggestions...

Отзывы: