Thermal Imaging IP Camera
User Manual
Overview
Issue V1.0 (2015-11-25)
7
Table 1-2
Multi-connector cable description
ID
Core
Function
Description
1
Orange wire
Cathode of alarm
output 1
Connect to the alarm output device.
White & black
Cathode of alarm
output 2
Yellow wire
Alarm output 1
White & blue
Alarm output 2
Gray wire
Cathode of alarm
input
Connect to the alarm input device.
Purple wire
Alarm input 1
Blue wire
Alarm input 2
2
Network port
Connect with an Ethernet cable.
3
-
Audio input (line
input)
Input audio signal and receive analog
audio signal from audio pickup and
other devices.
4
-
Audio output
Connect with sound box and other
external audio devices.
5
Brown wire
Connect with external PTZ and other
devices through the RS485 interface.
White wire
RS485RS-
6
-
DC 12V (2A)
Connect with 12 V DC power supply
through the power interface.
1.4
Functional Features
Adopts non-cooling IR focal plane sensor.
Detects 8~14μm LWIR.
Achieves the resolution of 420*315 pixels.
Provides a thermal sensitivity as high as 50 mK.
Supports special lens with 8mm / 15mm / 25mm / 35mm / 50mm focal distance
(optional).
Supports Polarity /LUT switchover: black hot/white hot/rainbow/ironbow
Allows users to set measuring point or area and show and detect temperature: point
measuring (with mouse), area measuring (highest temperature), and full-screen
measuring (highest temperature) (functioning as a temperature measuring and
prewarning product).