VAX 4000
Model 100/100A Upgradeto Model 105A
Order Number: EK–V411A–CG. A01
May 1994
Digital Equipment CorporationMaynard, Massachusetts
Страница 1: ...VAX 4000 Model 100 100A Upgrade to Model 105A Order Number EK V411A CG A01 May 1994 Digital Equipment Corporation Maynard Massachusetts...
Страница 2: ...ibed in this publication is authorized only pursuant to a valid written license from Digital or an authorized sublicensor Digital Equipment Corporation 1994 All Rights Reserved The postpaid Reader s C...
Страница 3: ...ocedure Overview 2 1 2 3 Unpacking the Kit 2 2 2 4 Upgrading the VMS Operating System 2 3 2 5 Replacing the CPU Module 2 4 3 Upgrading the VAX 4000 Model 100A System 3 1 In This Chapter 3 1 3 2 Proced...
Страница 4: ...t Cover 2 19 2 16 Installing the Original DSSI Cable on the Port Cover 2 20 2 17 Installing the Q bus Cable on the Port Cover 2 21 2 18 Installing the Blank Covers on the Port Cover 2 22 2 19 Installi...
Страница 5: ...les 3 15 3 12 Removing the CPU Module 3 17 3 13 Installing the DSSI Daughter Card 3 19 3 14 Connecting the External SCSI Cable to the CPU Module 3 20 3 15 Connecting the Single DSSI Cable to the Daugh...
Страница 6: ......
Страница 7: ...tal Services to schedule a system conversion It is your responsibility to perform a software backup before a Digital Services representative arrives at your site When the conversion is complete return...
Страница 8: ...Chapter 2 provides detailed upgrade conversion procedures for a VAX 4000 Model 100 Chapter 3 provides detailed upgrade conversion procedures for a VAX 4000 Model 100A Appendix A contains forms for the...
Страница 9: ...tation Order Number VAX 4000 Model 105A Installation Information EK 512AA IN VAX 4000 Model 105A Operator Information EK 513AA OP VAX 4000 Model 105A Customer Technical Information EK 514AA TI VAX 400...
Страница 10: ......
Страница 11: ...r 3 for the conversion of a VAX 4000 Model 100A The VAX 4000 Model 100A is identical to the VAX 4000 Model 100 except that the port cover is designed to accomodate a dual DSSI port The conversion of a...
Страница 12: ......
Страница 13: ...5 5 2H4 VMS 6 1 is acceptible 4 Shut down the operating system 5 Turn off the system power and remove the power cord 6 Disconnect all external cables 7 Remove the enclosure cover 8 Remove the memory S...
Страница 14: ...tall the SIMMs 22 Reinstall the enclosure cover 23 Connect the power cable signal cables and terminators to the system as desired 24 Remove the system medallion and install the new one 25 Have the cus...
Страница 15: ...01 1 Product conversion label 36 15946 00 1 Regulatory label 36 30382 23 24 1 NVAX CPU 54 21797 02 1 Medallion 74 37642 32 1 DSSI blank panel 74 46956 01 2 Expansion port cover 74 46957 01 1 Machine s...
Страница 16: ...ng system in the proper manner 5 Turn off the system power before installing the kit 2 5 Replacing the CPU Module To replace the CPU module 1 Disconnect the power cord from the wall outlet then from t...
Страница 17: ...ors from the present port cover and save the screws see Figure 2 2 Figure 2 2 Disconnecting the External Cables Terminators from the Port Cover 1 2 3 4 MLO 010800 Q bus ports Q bus cables may be attac...
Страница 18: ...CPU Module 3 Remove the enclosure cover by removing the two screws at the rear of the system box and sliding it forward see Figure 2 3 Figure 2 3 Removing the Enclosure Cover 1 2 MLO 010801 Screws En...
Страница 19: ...elves themselves Unscrew all six screws from the shelves leaving the topmost captive screw until last for support Leave the captive screws in position and save the Phillips screws for reinstallation o...
Страница 20: ...nternal power cables from the power supply Figure 2 5 6 Disconnect the pigtailed 2 pin DSSI power cable from the CPU module Figure 2 5 Note Some VAX 4000 Model 100s do not have the pigtailed power cab...
Страница 21: ...placing the CPU Module Figure 2 5 Disconnecting the Internal Power Cables 1 2 3 MLO 012287 Internal power cable Internal power cable with pigtailed DSSI power cable CPU module DSSI power cable connect...
Страница 22: ...See Figure 2 7 Caution Static electricity can damage integrated circuits Wear a wrist strap and place an antistatic mat under the system unit when working with the internal parts of the system unit No...
Страница 23: ...m 2 5 Replacing the CPU Module 3 Lift the memory module up and out of the enclosure and place it on an anti static mat Figure 2 7 Removing a SIMM Metal Board Clip MS44 Memory Modules MLO 009876 Upgrad...
Страница 24: ...Replacing the CPU Module 9 Disconnect the internal SCSI cable from the CPU module see Figure 2 8 Figure 2 8 Disconnecting the Internal SCSI Cable from the CPU Module 1 MLO 012288 Internal SCSI cable 2...
Страница 25: ...U Module 10 Remove the shelves by sliding them forward see Figure 2 9 and lifting them up from the enclosure see Figure 2 10 Figure 2 9 Sliding the Drive Mounting Shelves Forward 1 MLO 010806 Drive mo...
Страница 26: ...Upgrading the VAX 4000 Model 100 System 2 5 Replacing the CPU Module Figure 2 10 Lifting the Drive Mounting Shelves Upward MLO 010807 2 14 Upgrading the VAX 4000 Model 100 System...
Страница 27: ...dule and use a standoff removal tool to compress the posts so that each corner of the card can be lifted off individually Figure 2 11 When all four corners are loose lift the card out and place it on...
Страница 28: ...or on the CPU module b Disconnect the Q bus cable c Disconnect any internal communications options cables that are present in your system from the CPU module d Disconnect the CPU power cable from the...
Страница 29: ...Figure 2 13 The tabs are accessed through the tab cutouts on the port cover Slide the cover off pulling all cables carefully through the cable slots on the rear of the system box Figure 2 13 Removing...
Страница 30: ...cover see Figure 2 14 Save the screws nuts and washers for use in connecting the new port cover Figure 2 14 Removing Connectors from the Port Cover 1 2 MLO 010814 Nut driver used for bolts on the Q b...
Страница 31: ...Module 16 Install two alignment pins with washers on the new port cover for the original DSSI connector see Figure 2 15 Figure 2 15 Installing the Alignment Pins on the Port Cover 1 2 MLO 010815 Alig...
Страница 32: ...17 Install the single DSSI cable 17 03544 01 into the left DSSI port cutout see Figure 2 16 Figure 2 16 Installing the Original DSSI Cable on the Port Cover 2 1 MLO 010816 Original DSSI cable connect...
Страница 33: ...le 18 Install the Q bus cable 17 03545 01 into the Q bus cutouts on the port cover see Figure 2 17 Figure 2 17 Installing the Q bus Cable on the Port Cover 2 3 1 MLO 010817 Q bus cable connectors Nutd...
Страница 34: ...19 Install the blank covers into the two right DSSI external cutouts on the new port cover see Figure 2 18 Figure 2 18 Installing the Blank Covers on the Port Cover 2 1 MLO 012292 Blank covers Phillip...
Страница 35: ...all the SCSI cable 17 2944 01 into the SCSI cutout on the bottom of the port cover see Figure 2 19 Figure 2 19 Installing the SCSI Cable on the Port Cover 3 2 1 MLO 012293 SCSI cable connector Phillip...
Страница 36: ...e Q bus cables through the top cable cutout on the system box b Feed the SCSI cable through the bottom cable cutout on the system box c Hook the bottom flange of the cover plate onto the system box d...
Страница 37: ...r the tension of the connector gaskets If necessary slide the CPU module back until it disengages from the ten keyhole cutouts refer to Figure 2 21 b Use your finger in the semicircular cutout on the...
Страница 38: ...VAX 4000 Model 100 System 2 5 Replacing the CPU Module Figure 2 21 Removing the CPU Module PUSH PUSH MLO 012295 3 1 2 Spring clips Semicircular cutout Keyhole cutouts 10 2 26 Upgrading the VAX 4000 Mo...
Страница 39: ...module with the corresponding standoff pillars in the base of the enclosure Caution Ensure that you do not damage any of the CPU module components by exerting pressure on them c Press the CPU module a...
Страница 40: ...e Figure 2 22 Installing the DSSI Daughter Card MLO 012296 3 2 1 Daughter card Standoff CPU module connector Note For clarity cables not applicable to a particular step are omitted from some of the fo...
Страница 41: ...25 Connect the external SCSI cable 17 2944 01 to the CPU module see Figure 2 23 Figure 2 23 Connecting the External SCSI Cable to the CPU Module 1 2 MLO 012297 External SCSI cable External SCSI conne...
Страница 42: ...t the DSSI cable 17 03544 01 to the connector slot on the DSSI daughter card see Figure 2 24 Figure 2 24 Connecting the Single DSSI Cable to the Daughter Card 1 2 MLO 012298 Single DSSI cable Rear con...
Страница 43: ...Module 27 Connect the Q bus cable 17 3545 01 to the Q bus slot on the CPU module see Figure 2 25 Figure 2 25 Connecting the Q bus Cable to the CPU Module 2 1 MLO 012299 Q bus cable Q bus connector on...
Страница 44: ...shelves in the system box and connect the internal SCSI cable 17 03587 01 to the CPU module a Position the shelves by lining up the bracket tabs but do not slide them rearward yet see Figure 2 26 Fig...
Страница 45: ...ble to its connector on the CPU module see Figure 2 27 c Slide the shelves down and rearward into place so that the holes on the bracket tabs line up with their cutouts Figure 2 27 Reinstalling the Dr...
Страница 46: ...2 28 1 Tighten the topmost captive screw first so that the shelves do not fall and damage components underneath 2 Tighten the remaining captive screws 3 Replace and tighten the Phillips screws Figure...
Страница 47: ...e connectors on the CPU module are keyed so that you cannot install the module with an incorrect orientation Do not try to force a module into a connector with an incorrect orientation Note The SIMMs...
Страница 48: ...Upgrading the VAX 4000 Model 100 System 2 5 Replacing the CPU Module Figure 2 29 Installing a SIMM 2 1 MLO 012303 Sliding the module in Tipping it upright 2 36 Upgrading the VAX 4000 Model 100 System...
Страница 49: ...s see Figure 2 5 32 Reinstall the enclosure cover see Figure 2 3 33 Reconnect cables and terminators to the DSSI Q bus and SCSI connectors on the port cover as desired see Figure 2 30 Figure 2 30 Reco...
Страница 50: ...32 See Figure 2 31 a Peel the backing off the new medallion b Apply the new medallion in place of the original one Figure 2 31 Applying the New Medallion 1 MLO 010951 2 3 Backing New medallion Medalli...
Страница 51: ...the power up diagnostics 4 Turn off the system power and remove the power cord 5 Remove the enclosure cover 6 Remove the SIMMs memory modules 7 Remove the upper and lower drive mounting shelves 8 Dis...
Страница 52: ...llows 1 Make sure there is no external damage to the shipping container such as dents holes or crushed corners 2 Unpack the conversion kit and check its contents against the shipping invoice Table 3 1...
Страница 53: ...01 2 Expansion port cover 74 46957 01 1 Machine screw 8mm 90 10917 01 4 VAX 4000 100 100A Upgrade to Model 105A EK V411A CG 1 VMS multimedia Viking QA 001AA UW 1 Model 105A doc set QZ K04AB GZ 1 3 4 B...
Страница 54: ...ing the CPU Module To install the new CPU module convert to a VAX 4000 Model 105A 1 Disconnect the power cord from the wall outlet then from the system see Figure 3 1 Figure 3 1 Disconnecting the Powe...
Страница 55: ...U Module 2 Remove the enclosure cover by removing the two screws at the rear of the system box and sliding it forward see Figure 3 2 Figure 3 2 Removing the Enclosure Cover 1 3 2 1 2 MLO 010953 Screws...
Страница 56: ...elves themselves Unscrew all six screws from the shelves leaving the topmost captive screw until last for support Leave the capitve screws in position and save the Phillips screws for reinstallation o...
Страница 57: ...System 3 5 Installing the CPU Module 4 Disconnect the internal power cables from the power supply Figure 3 4 5 Disconnect the pigtailed 2 pin DSSI power cable from the CPU module Figure 3 4 Upgrading...
Страница 58: ...talling the CPU Module Figure 3 4 Disconnecting the Internal Power Cables 1 2 3 MLO 012306 Internal power cable Internal power cable with pigtailed DSSI power cable CPU module DSSI power cable connect...
Страница 59: ...icity can damage integrated circuits Wear a wrist strap and place an antistatic mat under the system unit when working with the internal parts of the system unit Note Note carefully the position of ea...
Страница 60: ...3 5 Installing the CPU Module 3 Lift the memory module up and out of the enclosure and place it on an anti static mat Figure 3 6 Removing a SIMM Metal Board Clip MS44 Memory Modules MLO 012304 3 10 U...
Страница 61: ...Installing the CPU Module 8 Disconnect the internal SCSI cable from the CPU module see Figure 3 7 Figure 3 7 Disconnecting the Internal SCSI Cable from the CPU Module 1 MLO 012305 Internal SCSI cable...
Страница 62: ...dule 9 Remove the shelves by sliding them forward see Figure 3 8 and lifting them forward and up from the enclosure see Figure 3 9 Figure 3 8 Sliding the Drive Mounting Shelves Forward 1 MLO 012307 Dr...
Страница 63: ...Upgrading the VAX 4000 Model 100A System 3 5 Installing the CPU Module Figure 3 9 Lifting the Drive Mounting Shelves Upward MLO 012289 Upgrading the VAX 4000 Model 100A System 3 13...
Страница 64: ...and use a standoff removal tool to compress the posts so that each corner of the card can be lifted off individually Figure 3 10 When all four corners are loose lift the card out and place it on an a...
Страница 65: ...or on the CPU module b Disconnect the Q bus cable c Disconnect any internal communications options cables that are present in your system from the CPU module d Disconnect the CPU power cable from the...
Страница 66: ...r the tension of the connector gaskets If necessary slide the CPU module back until it disengages from the ten keyhole cutouts refer to Figure 3 12 b Use your finger in the semicircular cutout on the...
Страница 67: ...X 4000 Model 100A System 3 5 Installing the CPU Module Figure 3 12 Removing the CPU Module PUSH PUSH MLO 012295 3 1 2 Spring clips Semicircular cutout Keyhole cutouts 10 Upgrading the VAX 4000 Model 1...
Страница 68: ...module with the corresponding standoff pillars in the base of the enclosure Caution Ensure that you do not damage any of the CPU module components by exerting pressure on them c Press the CPU module a...
Страница 69: ...le Figure 3 13 Installing the DSSI Daughter Card MLO 012296 3 2 1 Daughter card Standoff CPU module connector Note For clarity cables not applicable to a particular step are omitted from some of the f...
Страница 70: ...e 16 Connect the external SCSI cable 17 2944 01 to the CPU module see Figure 3 14 Figure 3 14 Connecting the External SCSI Cable to the CPU Module 1 2 MLO 012297 External SCSI cable External SCSI conn...
Страница 71: ...he Single DSSI Cable to the Daughter Card 1 2 MLO 012298 Single DSSI cable Rear connector slot on the daughter card Note If your system has the dual DSSI option run the dual DSSI in out cable 17 03778...
Страница 72: ...U Module 18 Connect the Q bus cable 17 3545 01 to the Q bus slot on the CPU module see Figure 3 16 Figure 3 16 Connecting the Q bus Cable to the CPU Module 2 1 MLO 012299 Q bus cable Q bus connector o...
Страница 73: ...g shelves in the system box and connect the internal SCSI cable 17 03587 01 to the CPU module a Position the shelves by lining up the bracket tabs but do not slide them rearward yet see Figure 3 17 Fi...
Страница 74: ...able to its connector on the CPU module see Figure 3 18 c Slide the shelves down and rearward into place so that the holes on the bracket tabs line up with their cutouts Figure 3 18 Reinstalling the D...
Страница 75: ...3 19 1 Tighten the topmost captive screw first so that the shelves do not fall and damage components underneath 2 Tighten the remaining captive screws 3 Replace and tighten the Phillips screws Figure...
Страница 76: ...e connectors on the CPU module are keyed so that you cannot install the module with an incorrect orientation Do not try to force a module into a connector with an incorrect orientation Note The SIMMs...
Страница 77: ...ing the VAX 4000 Model 100A System 3 5 Installing the CPU Module Figure 3 20 Installing a Memory Module 2 1 MLO 012303 Sliding the module in Tipping it upright Upgrading the VAX 4000 Model 100A System...
Страница 78: ...3 2 24 Place the new label 36 30382 23 24 whichever is appropriate for your country over the existing label 25 Remove the system medallion and install the new one 74 37642 32 See Figure 3 21 a Peel t...
Страница 79: ...ply the conversion label 36 15946 00 in any spot on the system box you wish 27 Have the customer reinstall system data if necessary 28 Fill out the forms in Appendix A 29 Return the original CPU modul...
Страница 80: ......
Страница 81: ...d a fee Return the original CPU module as follows 1 Obtain the serial number of the system being converted Customer Administrative Services CAS cannot process the order without this serial number 2 En...
Страница 82: ...igital Equipment Corporation 7 Complete both copies of the Installation Receipt The first copy is the customer s receipt It shows that the installation was completed and that Digital Services contacte...
Страница 83: ...procedures used Please fill out this form and return it to your Contract Administrator for updating the customer s contract Customer Previous System Model Number Previous System Serial Number Origina...
Страница 84: ...Mandatory Return Procedure and Forms A 2 Return Forms A 4 Mandatory Return Procedure and Forms...
Страница 85: ...contact you within the next several days to arrange for package pickup and return Keep this copy as your record of installation by Digital Equipment Corporation Note Contact the local CAS office to ob...
Страница 86: ...ory Return Procedure and Forms A 2 Return Forms CPU Module Packed for Return Customer Name Phone Number Customer Signature Digital Services Representative Signature A 6 Mandatory Return Procedure and...
Страница 87: ...ocal CAS office for filing with customer documents Note Contact the local CAS office to obtain the RA return authorization number You should have the Digital order number available Be sure to note the...
Страница 88: ...ory Return Procedure and Forms A 2 Return Forms CPU Module Packed for Return Customer Name Phone Number Customer Signature Digital Services Representative Signature A 8 Mandatory Return Procedure and...
Страница 89: ...to a VAX 4000 Model 105A This form must be filled out and returned with the original daughter card to ensure that the customer does not incur a penalty charge Return Authorization RA Number Digital O...
Страница 90: ......
Страница 91: ...Digital Equipment Corporation P O Box CS2008 Nashua NH 03061 Puerto Rico Phone 809 781 0505 Fax 809 749 8377 Digital Equipment Caribbean Inc 3 Digital Plaza 1st Street Suite 200 Metro Office Park San...
Страница 92: ......
Страница 93: ...asy to understand Organization structure of subject matter Figures useful Examples useful Index ability to find topic Page layout easy to find information I would like to see more less What I like bes...
Страница 94: ...CLASS PERMIT NO 33 MAYNARD MASS POSTAGE WILL BE PAID BY ADDRESSEE No Postage Necessary If Mailed in the United States DIGITAL EQUIPMENT CORPORATION Information Design and Consulting MRO1 3 K10 BS 200...