v

PowerGrade Option Warranty

This document is a supplement to the warranty information and terms
provided with your Prioris Server.

PowerGrade Options Limited Warranty

PowerGrade option kits are qualified Digital Personal Computer Hardware Options that
are warranted to be free from defects in material and workmanship under normal use.
This Limited Warranty does not extend to any Product not purchased from Digital or
from an Authorized Digital Reseller.  This Limited Warranty also does not extend to
any Product that has been damaged or rendered defective (a) by operation outside the
usage parameters stated in section four entitled 

Warranty Exclusions and Limitations of

Liability 

of the

 Digital Personal Computers Warranty and Service Information

document; (b) as a result of accident, misuse or abuse; (c) as a result of service or
installation by anyone other than Digital, an Authorized Digital Reseller, or an
Authorized Digital Service Provider, or (d) by the use of parts not manufactured or sold
by Digital.

Upon installation in the appropriate Prioris Server, the PowerGrade option will carry
the longer of either a one year Return-to-Digital warranty or the remainder of the
warranty period for the Digital Prioris Server.

Digital warrants that the PowerGrade option you have purchased from Digital, or from
an Authorized Digital Reseller, will function correctly when properly installed in the
appropriate Prioris server if the CPU contained within this kit is within one stepping
(version) of the CPU(s) that originally came with your Prioris Server.

Warranty Exclusions and Limitations of Liability

Installation of a PowerGrade option requires handling and installing a CPU chip, which
must be performed with extreme care to avoid product damage.  Therefore, Digital
recommends that the installation of this option be performed by an Authorized Digital
Service Provider.

Please refer to the “Digital Personal Computers Warranty and Service
Information” document provided with your Digital Prioris Server for further
information.

Содержание Prioris MX 6200

Страница 1: ...Prioris MX 6200 Server PowerGrade with Pentium Pro Chip Upgrade Installation Guide Order Number ER PCB4U IA A01 Digital Equipment Corporation...

Страница 2: ...erence will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the us...

Страница 3: ...on the Main Logic Board 4 Replace the Panel and Reconnect the Cables 5 Power Up the Server and Update Your BIOS 5 Powergrade Installation 6 Remove the CPU Module 6 Install the CPU Chip 7 Install the V...

Страница 4: ...odule 10 Figure 7 Installing a Voltage Regulator Module 11 Figure 8 CPU Module Switch Location 12 Figure 9 Installing a CPU Module in an MX 6200 Server 14 Tables Table 1 Kit Contents 1 Table 2 CPU Mod...

Страница 5: ...Authorized Digital Service Provider or d by the use of parts not manufactured or sold by Digital Upon installation in the appropriate Prioris Server the PowerGrade option will carry the longer of eith...

Страница 6: ...vi...

Страница 7: ...ny video option card if installed and enable the internal VGA controller Once the BIOS process has completed successfully you can then reinstall any video option card You must install the new BIOS bef...

Страница 8: ...ROM and Create Diskettes During this procedure you will create a crisis recovery diskette BIOS upgrade diskette and a System Configuration Utility SCU diskette The Quick Launch CD ROM contains the req...

Страница 9: ...he SCU main menu 3 From the main menu use the arrow keys to highlight an item and then press Enter to select it Press F1 at any time for help about a selection 4 Select the Advanced Control Group and...

Страница 10: ...Set Switches on the Main Logic Board Make sure that the following switches are set SW1 1 BIOS upgrade Enabled On SW1 3 Boot block update Enabled On 1 2 3 1 2 3 4 5 DEC01052 6a ON Figure 1 MX 6200 Main...

Страница 11: ...r BIOS Use the following procedure to update your BIOS 1 Power up and boot the server with the BIOS Upgrade diskette installed in drive A 2 Change the directory to upgrade Example A cd upgrade 3 At th...

Страница 12: ...wrist and connect the grounding clip to a non painted metal surface of the computer s chassis 3 Using a Phillips screwdriver unscrew and remove the CPU module retaining bracket A in Figure 2 4 Graspin...

Страница 13: ...shipping holder by removing the retaining clip To remove the clip press down firmly on the top of the clip If needed press down with a small screwdriver in the hole of the second style clip shown in...

Страница 14: ...erPowerGrade 8 2 Remove the CPU heat sink assembly from its shipping holder Do not pull the heat sink off of the CPU chip Use care not to bend the pins DEC01232 2 Figure 4 Removing the New CPU from it...

Страница 15: ...the lever of the empty CPU socket Position the pins of the new CPU chip in the socket of the CPU module Note that the pins are denser on one side for correct orientation 4 Lower the lever to engage th...

Страница 16: ...10 5 Install the retaining clip by installing the back side of the clip first then pressing it into place as shown in the circle in Figure 6 DEC01211 4 DEC01211 5 Figure 6 Installing the Clip to Secu...

Страница 17: ...tor Module s Install a voltage regulator module into the empty voltage regulator socket on the CPU module Note A voltage regulator module must be installed for each CPU that is installed in the system...

Страница 18: ...h a speed of 200 MHz as listed in Table 2 Table 2 CPU Module CPU Speed Switch Settings CPU Speed Switch Position Description 200 MHz SW4 1 Down 66 MHz bus frequency SW4 2 Down 3 bus core frequency rat...

Страница 19: ...CPU slot on the main logic board 2 Secure the CPU module to the main logic board using the previously removed retaining bracket screw and a Phillips screwdriver Figure 9 Install any Video Option Card...

Страница 20: ...PriorisMX6200ServerPowerGrade 14 DEC01054 3 Figure 9 Installing a CPU Module in an MX 6200 Server...

Страница 21: ...n menu 3 From the main menu press the up or down arrow to highlight an item and then press Enter to select it Press F1 at any time for help about a selection 4 From the main menu select Configure Comp...

Страница 22: ...risis Recovery diskette into drive A and reboot the computer NOTE Remember to return the switch to its Normal position after using the crisis recovery diskette Bulletin Board Access For future referen...

Отзывы: