Step 8: Checking the Power-Up Test Results
The power-up test can take several minutes to complete, depending on the
number of installed options you have and on which default settings you use:
•
If the power-up test results on the screen are similar to the results in
Figure 1–1, the system has passed the power-up test. Go to step 9.
•
If the power-up test results on the screen are not similar to the results in
Figure 1–1, the system has not passed the power-up test. Go to substep 1.
Figure 1–1 Successful Power-Up Test Screen
KA55-A or KA51-A or KA56-A V2.6, VMB 2.15
!
Performing normal system tests.
74..73..72..71..70..69..68..67..66..65..64..63..62..61..60..59..
58..57..56..55..54..53..52..51..50..49..48..47..46..45..44..43..
"
42..41..40..39..38..37..36..35..34..33..32..31..30..29..28..27..
26..25..24..23..22..21..20..19..18..17..16..15..14..13..12..11..
10..09..08..07..06..05..04..03..
Tests completed.
#
>>>
$
!
Central Processing Unit (CPU) name, Firmware version number, and
Virtual Memory Boot (VMB) version number
"
Read-Only Memory (ROM) based diagnostics countdown
#
Status message
$
Console prompt
1.
Write down the error messages and the error summaries. Figure 1–2
shows an example of an error message and an error summary.
2.
Set the on/off switch to the off (O) position.
3.
Make sure that all the connections you made in step 3, step 4, step 5, and
step 6 are correct.
4.
Set the on/off switch to the on ( | ) position.
5.
If an error report is still displayed, see the MicroVAX 3100 Model 85/95/96
Troubleshooting and Diagnostic Information manual.
1–8 Installation Procedure