Содержание DECserver 300

Страница 1: ......

Страница 2: ...Cserver 300 terminal server It is intended for the server manager Supersession Update Information This is a new manual Software Version DECserver 300 Vl 0 This manual applies to Version 1 0 of DECserv...

Страница 3: ...bility is assumed for the use or reliability of software on equipment that Is not supplied by Digital or its affiliated companies Copyright 1989 by Digital Equipment Corporation All Rights Reserved Pr...

Страница 4: ...The Console Port The DECserver 300 Self Test Types of Errors Fatal and Non Fatal The Seven Segment Status Display Diagnostic Status and Error Codes Server Software Status Codes DECserver 300 TEST Com...

Страница 5: ...ory Resources 4 8 4 5 No Console Messages 4 9 4 6 Down Line Loading Problems Code 3 on the Status Display 4 10 4 6 1 Down Line Load Starts Then Fails 4 10 4 6 2 Down Line Load Does Not Start 4 12 4 7...

Страница 6: ...kaging a DECserver for Shipping 8 2 8 3 Forwarding Up Line Dump Data 8 2 Index Figures 1 1 Network Components 1 1 1 2 Composition of Network Components 1 2 2 1 DECserver 300 Seven Segment Status Displ...

Страница 7: ......

Страница 8: ...1 Chapter 2 Chapter 3 Chapter 4 Chapter 5 Chapter 6 Chapter 7 Chapter 8 Briefly introduces DECserver 300 problem solving Describes the troubleshooting tools and the hardware and software features that...

Страница 9: ...es indicate keywords that must be entered You can enter them in either uppercase or lowercase You can abbreviate command keywords to the fust three characters or the minimum unique abbreviation lowerc...

Страница 10: ...component is broken down into its parts as shown in Fig ure 1 2 In Figure 1 2 hardware devices are represented by solid line rectangles Software is represented by rectangles outlined with dashed line...

Страница 11: ...t Ports SER 1CE NODE ElHERNET CABLE REPEATERS CONNECTORS Ethernet Component Parts ElHERNET TRANSCEIVER Service Node Component Parts ETHERNET TRANSCEIVER DECs rver 300 TRANSCEIVER CABLE TRANSCEIVER CAB...

Страница 12: ...er installation you can use the DEFINE SETPORTcommands to set up the console port with other values for speed character size and parity Port 1 is the default console port Notice that the factory set d...

Страница 13: ...The DECserver 300 seven segment status display is located on the control indicator panel of the server unit see Figure 2 1 The seven segment status display is also referred to as the status display Th...

Страница 14: ...two general categories Diagnostic status and error codes these codes are displayed while the server self test diagnostics are running Server software status codes these codes are displayed after succ...

Страница 15: ...error self test stops code 9 flashes and the diagnostic dot blinks in the status display After self test the diagnostic dot See Table 2 1 indicates the following If the diagnostic dot remains off afte...

Страница 16: ...ndicates that the timer tests are running Indicates that the ROM subsystem tests are running Indicates that the Ethernet subsystem tests are running tested in internalloopback Indicates that Ethernet...

Страница 17: ...appears in the display Table 2 2 Server Software Status Codes Seven Segment Status Display SOFTWARE STATUS CODES 4 3 2 o Pattern Indication Indicates that the server is requesting a down line load of...

Страница 18: ...ommand lets you test a server port or port device The TEST LOOP command lets you test communication between the server and any DECnet node Refer to the Terminal SenJer Commands and Messages manual for...

Страница 19: ...ata to the internal port hardware the external port hardware or to the port device When you specify that the data be sent to the internal or external port hardware the data is looped back and the DECs...

Страница 20: ...Ethernet circuits Loop assist tests loop data between a source node and a destina tion node on the Ethernet the tests use a third node on the Ethernet to relay the data This third node is called an as...

Страница 21: ......

Страница 22: ...ror message 913 the server automatically initializes 3 If interactive users can enter server commands have them finish their active sessions and then log out from the server If users cannot enter comm...

Страница 23: ...affect all ports but affects an individual port see Chapter 5 6 If a problem is evident from an error message on a terminal check the error message in the Terminal Server Commands and Messages manual...

Страница 24: ...cable at the server and at the wall outlet Correction Check the wall outlet using another electrical device or plug the server into another outlet If you have fuses for your wall outlet or power cord...

Страница 25: ...ration sales office for service or replacement See Chapter 8 4 2 Diagnostic Dot Is Off Fatal Error or Test in Progress If the diagnostic dot remains off for longer than two minutes after self test beg...

Страница 26: ...ert the server power cord Continue to hold the reset switch in for one second after power up Resetting Sl causes the factory set port characteristics to be re loaded into the server permanent database...

Страница 27: ...sed to store the characteristics is faulty Return the server to Digital Equipment Corporation for repair or for replacement See Chapter 8 4 3 4 Error Messages 935 and 936 4 4 Local 935 Service charact...

Страница 28: ...Image load not attempted Local 950 Troubleshooting procedures should be followed Local 952 Enter Ap to restart self test Problem Problem Problems on A Ports The incorrect Ethernet port has been select...

Страница 29: ...r for replacement b If the diagnostic dot stays on without blinking go to step 3 to isolate and to determine the faulty unit 3 Unplug the Ethernet loopback connector from the Ethernet connector on the...

Страница 30: ...supplied with the server to the ThinWire Ethernet port 3 Select the ThinWire port by pushing in the selector switch and ensure that the ThinWire LED is illuminated 4 Initialize the server by pressing...

Страница 31: ...Errors is incrementing server memory is full Refer to the following corrections if the Resource Errors is incrementing in the display Correction Adjust groups to restrict the least used nodes from be...

Страница 32: ...that the device is physically connected to that port on the server unit The console telIDinal is faulty Correction Refer to Chapter 5 for troubleshooting procedures for individual port devices The in...

Страница 33: ...sequence of messages appears on the console terminal at regular in tervals Local 953 Attempting to locate load host rJrame format Local 955 Host hosl address located rJrame format Local 956 Requesting...

Страница 34: ...the server software image is not defined on the load host Correction The server SOFTWARE characteristic should be defined as SH1601ENG The DECserver 300 Management man ual explains how to reset SOFTW...

Страница 35: ...l name SYS SYSROOT DECSERVER This is the procedure used to configure a DECserver 300 unit in the load host database 2 Enter number 1 in the menu of options This option displays the DECnet address the...

Страница 36: ...S hosts only For example on a load host running VMS the logical symbol MOM LOAD that must point to the DECserver load directory is not defined Correction On VMS systems the logical symbol MOM LOAD mus...

Страница 37: ...nnection is on Service is enabled on the service circuit The following is an example of the NCP commands needed to per form these checks and the NCP output NCP SHOW EXECUTOR STATUS Node Volatile Statu...

Страница 38: ...same Ethernet as the server to be a load host for the DECserver 300 unit Have the system manager on the load host add the server to the load host database by running the DSVCONFIG procedure Correction...

Страница 39: ...to up line dump the server software ifthe server s DUMP characteristic is set up as en abled Problem A fatal hardware error has been detected Correction There is no corrective procedure for this prob...

Страница 40: ...this problem Record the values for the five parameters in the error message Send this data in a software performance report SPR and the dump file to Digi tal Equipment Corporation See Chapter 8 After...

Страница 41: ...e Problems 4 18 H you have only a few devices attached to a DECserver individual port or port de vice problems may appear to be a single problemaffecting all ports Ifthe problems in Sections 4 1 to 4...

Страница 42: ...that the power switch is on 3 if the device has fuse replace it if the device has a circuit breaker reset it If the power indicator stays off for more than one minute assume that the device is faulty...

Страница 43: ...t speed of the server port The output speed of the device must match the input speed of the server port Match the device parity and the character size to the values for and parity for the port in the...

Страница 44: ...the following configurations A character size of 8 bits no parity or a character size of 7 bits even parity An input and output speed set to 75 110 134 150 300 600 1200 1800 2000 240Q 4800 9600 or 19...

Страница 45: ...is faulty Return the DECserver 300 unit to Digital Equipment Corporation see Chapter 8 If you do not specify a value for the COUNT option in the TEST PORT command the default count is in effect and 2...

Страница 46: ...t connector on the control indicator panel From another ter minal enter the TEST PORT LOOPBACK EXTERNAL com mand using the faulty port number You must disconnect the tenninal to install the loopback c...

Страница 47: ...l operator s guide Use the SHOW MONITOR PORT n CHARACTERISTICS com mand to display the values currently set for flow control The SHOW MONITOR PORT n STATUS command displays the oper ating condition of...

Страница 48: ...user can transfer files to and from service nodes or to and from remote PCs that are attached locally to service nodes Successful file transfers between a port user s PC and a service node depend on...

Страница 49: ...s The command example shown is in continuation format SET TERMINAL PASSALL NOHOSTSYNC NOTTSYNC NOBROADCAST _ EIGHTBIT NOWRAP 5 4 A Line Printer Fails at a Remote Access Port 5 8 A line printer is a po...

Страница 50: ...or more ports make sure the system manager has the correct service name Garbled characters or nonsense characters are printed in VMS host initiated print requests Correction Check the AUTOBAUD charac...

Страница 51: ...cts service sessions and the port is logged out You can de fine the port characteristic INACTIVITY LOGOUT as ENABLED Then if a local user has no active sessions the server logs the user out automatica...

Страница 52: ...apter 7 If the problem occurs during communication with a single service the problem is probably with the service node hardware including the Ethernet interface The problem may also be in the service...

Страница 53: ...t to the service This condition means that the service node has crashed or is otherwise unreach able You can check the node status using the SHOW NODE SUIv1MAR Y command with the node name Report the...

Страница 54: ...pt to reconnect to the service This condition indicates a problem with the LAT software on the service node Report the problem to the service node system manager Local 226 Connection to service name n...

Страница 55: ...ay the groups do not match Determine the groups that are enabled for the service node Then adjust the AUTHORIZED GROUPS list for the port as described in the DECserver 300 Management manual 6 4 Server...

Страница 56: ...the LAT documentation that comes with your operating system The number of service nodes on the network exceed the value for the server s node limit characteristic Correction Use group codes to restric...

Страница 57: ......

Страница 58: ...ual describes the counters and pos sible error indications Note that Ethernet problems can also be indicated by down line load or up line dump failures Problem Or Or The counters listed on the right h...

Страница 59: ...dicates a successful test Message 513 appears if the returned data was cor rupted or if the test timed out with no response from the target node IfTEST LOOP fails work with your network manager to res...

Страница 60: ...stem Con tact your Digital Equipment Corporation sales representative for more information 8 1 Before You Contact Digital Equipment Corporation To ensure a prompt solution Be sure the load host contai...

Страница 61: ...nt Corporationfor repair or for replacement pack the unitcarefully Ifpossible you should use the original ship ping carton and packaging material 8 3 Forwarding Up Line Dump Data 8 2 Ifa fatal bugchec...

Страница 62: ...rvice 8 1 Down line loading problems 7 1 DSR signal using on printers 5 10 E Error 201 or 206 6 2 Error 202 or 207 6 3 Error 224 or 264 6 2 Error 226 or 266 6 3 Error 711 or 715 6 5 Error 711 716 or 7...

Страница 63: ...troubleshooting 5 8 using signal check 5 9 Index 2 Problem on all ports 3 1 R RCF Remote Console Facility 2 9 Remote Console Facility RCF 2 9 Repackaging a DECserver for shipping 8 2 Reporting proble...

Страница 64: ...and 2 9 with TEST SERVICE command 2 8 Testing communication between server and a DECnet node 2 8 2 9 7 2 between server port and service node 2 8 Troubleshooting tools for 2 1 what to do first 3 1 u U...

Страница 65: ......