Installation Procedure
The AUI MM-10 installs into one of the Carrier Card slots and is hot-swappable.To install the AUI MM-10,
complete the following steps. A Phillips-head screwdriver is required.
Note: Installing MM-10s into the DIGITAL MultiSwitch Hub 624T requires prior installation of the DIGITAL
MultiSwitch Hub 624T Carrier Card, part number DLXMC-MA, which is not hot-swappable.
Note: Only the right-side slot of the Carrier Card provides power to an AUI MM-10. If you intend to connect the
module to a nonpowered device, connect it to an AUI MM-10 installed in the right-hand slot of the carrier card.
1
Hold the AUI MM-10 by its bezel and align the edges of the MM-10 (1) with the card guides (2) in the
Carrier Card.
2
Push the AUI MM-10 into the slot until it is firmly seated inside the module.
3
Align and securely fasten the two screws.
4
Push the slide latch on the DB-15 connector to the unlocked position. Connect a MAU (1) or an AUI port
cable (2). Push the slide latch to the locked position. Attach a MAU or an end device to the cable.
For further configuration and LED state information, see the DIGITAL MultiSwitch Hub 624T Installation and
Configuration manual.