- 13 -
*1 L = Live line for AC input
N = Neutral line for AC input
FG = Ground terminal to be connected to the FP housing
Recommended ring terminal: V2-MS3 or equivalent
(Manufactured by JST Co.)
• To prevent an electric shock, be sure to turn FP unit’s main power supply OFF before attach-
ing the power cord terminals to the FP unit’s power terminal strip.
• Be sure to use only the FP unit’s rated power level. Using any other level of power can
damage both the power supply and the FP unit.
• Since the FP is not equipped with the power switch, be sure to connect a breaker-type
power switch to the FP unit’s power cord.
6
Wiring the FP
WARNINGS
• Use thick wire (2 mm
2
max.) for the FP's power cable. Be sure that the cable is
twisted near the ring terminals.
• Use ring terminals with the following dimensions:
•
To prevent the power terminals from being short-circuited due to a loose
screw, use ring terminals with insulating sleeves.
Rear of FP
L N FG
L
N
FG
Ring terminal *1
Power input
terminal block