Junction box accessory
Page 86
●
The termination jumpers are there to ensure correct 120 Ohm
termination to the serial ports. These will all be fitted by default but if
a port requires no termination then that port’s jumper can be
removed.
●
Secure the accessory cables within the junction box with cable ties
(not supplied).
●
Refit the lid securely to ensure the waterproof integrity of the unit.
Figure 33 Junction box connections
TB11
TB5
TB3
JP3
JP5
JP6
JP4
JP2
JP1
TB6
TB8
TB9
TB7
TB4
TB1
TB2
TB10
CO
M
RX B
RX A
TX
B
TX
A
PILOT
BLUE
SIGN
N
P
N
P
SILENT
SENSOR 3
RX C
O
M
RX B
RX A
CO
M
RX B
RX A
TX
B
TX
A
LONG RANGE
DGPS
EXT DISPLAY
CHASSIS
SENSOR 2 SENSOR 1
RX C
O
M
RX B
RX A
RX C
O
M
RX B
RX A
CO
M
RX B
RX A
TX
B
TX
A
EXT DISPLAY
NC
CO
M
CHASSIS
ALARM
Secure cables
with cable ties
Solder braid/drain wire
to wire links provided
SENSOR 1
SENSOR 2
SENSOR 3
EXT DISPLAY
PILOT
LONG RANGE
DGPS
EXT DISPLAY
Termination
jumpers
Sensor data input ports
Bidirectional data ports
Drain wire
Clamp exposed braid
to wire links provided
Содержание CLA2000
Страница 1: ...CLA2000 CLASS A AIS TRANSPONDER Installation and Operation Manual...
Страница 10: ...Table of contents Page 8...
Страница 18: ...Notices Page 16...
Страница 20: ...Introduction Page 18...
Страница 26: ...Installation and configuration Page 24 Figure 5 Desk mounting the AIS transceiver...
Страница 42: ...Installation and configuration Page 40...
Страница 86: ...Technical information Page 84...
Страница 98: ...Technical specification Page 96...
Страница 102: ...Installation record Page 100...
Страница 103: ......
Страница 104: ...support digitaldeepsea com 202 0919 1...