Installation
Page 41
4.4.3
Sensor configuration
The
Smarter Track Class A
transceiver has seven NMEA0183 (IEC61162-1/2) data ports for connection of
ship’s sensors and display equipment as described in Table 3. There are three input ports for ship’s sensor
data and three bidirectional ports for connection of display equipment such as Radar or electronic chart
displays. It is recommended that an AIS compatible electronic charting system is connected to the
Smarter
Track Class A
transceiver for display of AIS targets. To comply with IMO regulations the AIS must be
connected to speed over ground (SOG), course over ground (COG), heading, rate of turn (ROT) and position
information sources.
The three sensor ports are input only data ports for the connection of data from ships sensors. The four
remaining ports are I-directional high speed connections supporting data input and output from the AIS. These
ports are suitable for connection to ECDIS, AIS enabled RADAR displays and Pilot equipment.
All data input connections are optically isolated.
Table 3
Serial data ports
All sensor ports can be configured via the sensor configuration menu which can be found under the Main
menu>Installation>Sensor configuration menu option.
The sensor configuration menu also includes the ability to disable the requirement for external GPS sensors to
provide a DTM (Datum) sentence, as not all external GPS devices provide this sentence.
4.4.4
Junction box connections
The junction box provides screw terminal connections for each of the seven data ports. The connections and
functions of each connection are defined in Table 4. All connections are labeled on the junction box PCB for
clarity. A diagram showing connections available inside the junction box is provided in Figure 44.
Use of shielded cable is recommended when connecting ships sensors and display systems to the junction box
Connect the cable shield to the terminal block marked ‘shields’ in the junction box. It is possible to remove the
PCB from the junction box enclosure to aid connection of cables to the screw terminals during installation.
Data port
Function
Type
Default Baud rate
1
Sensor 1 input
(DGPS -
COG/SOG/LAT/LON)
Receive only
4800
2
Sensor 2 input
(Rate of Turn)
Receive only
4800
3
Sensor 3 input
(Gyro heading)
Receive only
4800
4
External display / ECDIS
Bi-directional
38400
5
Pilot port
Bi-directional
38400
6
Long Range
Bi-directional
38400
7
DGPS beacon receiver
Bi-directional
4800
If an external GPS device which does not provide a DTM sentence is connected to the
transceiver and the transceiver is configured to require DTM sentences, the external GPS data
will not be accepted by the transceiver. If no DTM sentence is required the WGS84 datum will be
used as a coordinate origin and the external GPS device must be configured to output position
using this datum.
Do not connect the shield of both the external equipment and the junction box. Connect at only