background image

To access the AGR screen later, select

Calibration

,

1PT CAL

, and

wait 15 seconds for the AGR screen.

Settings Menu

Use the

Settings

menu to set the depth units, pitch units, roll offset, and

telemetry channel. Set the remote display to match receiver depth and
pitch settings.

Height-Above-Ground (HAG) Menu

HAG is the distance from the ground to the base of the receiver while it is
held. Setting HAG on the Main menu lets you take accurate below-ground
depth measurements without having to place the receiver on the ground.

Max Mode

Max Mode helps obtain depth/data readings in high-interference areas
when readings are unstable.

l

The drill head must remain still during Max Mode readings.

l

Hold the trigger at least five seconds to enter Max Mode. Do not
consider the data useful unless the reading is stable before the Max
Mode timer is full.

l

Always take three Max Mode readings; all must be consistent.

See the system operator's manual for additional important information on
the use of this feature.

Signal Attenuation

An

A

icon may appear on the roll indicator and FO results when the

receiver is attenuating the Tx signal for depths shallower than 8 ft. This is
normal. See the operator's manual if the signal strength is flashing,
indicating extreme interference.

Watch our DigiTrak

®

training videos at

www.YouTube.com/DCIKent

Printed:

10/9/2018

- 4 -

Отзывы: