Page 1 of 4
IP7-ST
/
STX
Getting Started Guide
Introduction
The IP7-ST/STx IP Intercom endpoint enables 2-way IP audio from an
analog call station with
TalkMaster™ software and/or VoIP Systems
supporting industry standard SIP 2.0 (VoIP) protocols. Standard features
include, PoE/External Power, Dual Ethernet ports and Talk/Relay/Sensor
connections.
The ST(x) supports several types of call stations:
•
PNL-CISx Single Transducer call stations. Single Transducer call stations
use a single speaker as both a speaker and as a microphone
•
Aiphone™ LE / LS series 3-wire call station
•
Aiphone™ IE / IF series 2-wire call station
•
Call stations with a separate microphone, speaker and Call button
The ST(x) may also be used to drive an Analog Paging Amplifier.
The IP7-ST/STx is configured using TalkMaster Admin Console software.
This
Getting Started
booklet covers basic hardware installation and software
configuration of the IP7-ST/STx.
IP7-ST/STX Installation
Important Installation Guidelines
•
Use 18-20 AWG
shielded
, twisted wire for microphone signals
•
Use 18 AWG wire for speaker and signaling connections.
•
Avoid sharing AC power and audio in conduit runs
•
Do not install near power distribution equipment or noise generating
equipment such as stepper motors
•
Conform to industry standard practices for grounding
PNL-CISx Single Transducer Call Station Installation
Relay Output (Optional)
Cat-5/6 Cable to
Network Switch
PoE / 9VDC - 32VDC
2 Conductor Wire
18-20 AWG
Twisted Shielded
Sensor Input (Optional)
2 Conductor Wire
(No Connection)
•
Set the internal
ST-MIC
switch
to the
ST
setting
•
Connect
SPKR 8Ω+
and
SPKR
8Ω-
(J2-6 and J2-7) to the
speaker terminals on the call
station (polarity independent)
•
Connect
TALK
(J2-5) to one
contact on the call station’s
TALK button
•
Jumper the remaining contact
on
the call station’s TALK button
to one of the speaker terminals (this wire should be limited to 10ft or 3
meters)
•
Connect GND (J2-4) to the shield of the shielded wire. Do not connect the
shield at the door station
Please refer to the IP7-ST/STx Reference Manual available on the
Software
Installation CD
for additional information on installation and setup
i
Talk Button
Talkback Speaker
No Connection
J1
J2
J3