background image

Page 1 of 4 

 

IP7-FD 

Getting Started Guide 

 

 

Introduction 

Digital Acoustics IP7-FD enables Full Duplex IP audio to support 
simultaneous speaking in hands free conversation with 

TalkMaster™ 

software and/or VoIP Systems supporting industry standard SIP 2.0 (VoIP) 
protocols. 

The “FD” is designed to work in tandem with Digital Acoustics’ 

“Full Duplex” call stations and enclosures for a compete ‘endpoint’ solution.  
Standard features include PoE/External Power, Dual Ethernet ports and 
Talk/Relay/Sensor connections. 
 
The FD is configured using the TalkMaster Admin Console software. This 

Getting Started

 booklet covers basic hardware installation and software 

configuration of the IP7-FD. 

 

IP7-FD Installation

 

 

 

 

Important Installation Guidelines 

  Use two conductor 18-20 AWG twisted, 

shielded

 wire for Microphone 

connections. 

The Microphone wire can not be in the same jacket as the 

Speaker wire

  

  Select 18 AWG for Speaker connections. The TALK, RELAY and Sensor 

wire wires may share the same jacket as the Speaker wire 

  Avoid sharing AC power with audio in long conduit runs 

  Do not install near power distribution equipment or noise generating 

equipment such as stepper motors  

  Conform to industry standard practices for grounding 

 
 
IP7-FD Full Duplex

 - Call Station Installation 

The IP7-FD is designed to be used with full duplex call stations supplied by 
Digital Acoustics.  Contact Technical Support for recommended design 
criteria for other call stations.

 

  Connect 

MIC+

 (J2-1) and 

MIC-

 (J2-2) from the IP7-FD to the Microphone 

terminals in the call station.

 The Microphone wire can not be in the 

same jacket as the Speaker wire

 

  Connect 

GND

 (J2-4) from the IP7-FD to the shield of the shielded wire on 

the Microphone cable. Do not connect the shield at the call station 

  Connect 

SPKR 8Ω+

 (J2-6) and 

SPKR 8Ω-

 (J2-7) from the IP7-FD  to the 

terminals of the 8 ohm speaker in the call station (polarity independent)   

  Connect 

TALK

 (J2-5) from the IP7-

FD to one contact on the call station’s 

TALK button 

  Connect the 2nd contact of the call 

station’s TALK button to

 GND

 (J2-4). 

Or connect the 2nd contact of the call station’s TALK button to either of the 
speaker terminals in the call station 

 

 

 

 

 

i

 

Please refer to the IP7-FD Reference Manual available on the 

Software 

Installation CD

 for additional information on installation and setup 

Отзывы: