Page 1 of 4
IP7-FD
Getting Started Guide
Introduction
Digital Acoustics IP7-FD enables Full Duplex IP audio to support
simultaneous speaking in hands free conversation with
TalkMaster™
software and/or VoIP Systems supporting industry standard SIP 2.0 (VoIP)
protocols.
The “FD” is designed to work in tandem with Digital Acoustics’
“Full Duplex” call stations and enclosures for a compete ‘endpoint’ solution.
Standard features include PoE/External Power, Dual Ethernet ports and
Talk/Relay/Sensor connections.
The FD is configured using the TalkMaster Admin Console software. This
Getting Started
booklet covers basic hardware installation and software
configuration of the IP7-FD.
IP7-FD Installation
Important Installation Guidelines
•
Use two conductor 18-20 AWG twisted,
shielded
wire for Microphone
connections.
The Microphone wire can not be in the same jacket as the
Speaker wire
•
Select 18 AWG for Speaker connections. The TALK, RELAY and Sensor
wire wires may share the same jacket as the Speaker wire
•
Avoid sharing AC power with audio in long conduit runs
•
Do not install near power distribution equipment or noise generating
equipment such as stepper motors
•
Conform to industry standard practices for grounding
IP7-FD Full Duplex
- Call Station Installation
The IP7-FD is designed to be used with full duplex call stations supplied by
Digital Acoustics. Contact Technical Support for recommended design
criteria for other call stations.
•
Connect
MIC+
(J2-1) and
MIC-
(J2-2) from the IP7-FD to the Microphone
terminals in the call station.
The Microphone wire can not be in the
same jacket as the Speaker wire
•
Connect
GND
(J2-4) from the IP7-FD to the shield of the shielded wire on
the Microphone cable. Do not connect the shield at the call station
•
Connect
SPKR 8Ω+
(J2-6) and
SPKR 8Ω-
(J2-7) from the IP7-FD to the
terminals of the 8 ohm speaker in the call station (polarity independent)
•
Connect
TALK
(J2-5) from the IP7-
FD to one contact on the call station’s
TALK button
•
Connect the 2nd contact of the call
station’s TALK button to
GND
(J2-4).
Or connect the 2nd contact of the call station’s TALK button to either of the
speaker terminals in the call station
i
Please refer to the IP7-FD Reference Manual available on the
Software
Installation CD
for additional information on installation and setup