background image

 

DigiShot

®

 Plus CE4 Tagger

 | 

UTM-00330

 | 

Rev 5

 

SVN 34374B

 | 

2019

APPROVER:__________________________________________________________________

2019/01/17

Vinesh Naidoo 

yyyy/mm/dd

APPROVED

Содержание Plus CE4 Tagger

Страница 1: ...DigiShot Plus CE4 Tagger UTM 00330 Rev 5 SVN 34374B 2019 APPROVER _________________________________________________ 2019 01 17 Vinesh Naidoo yyyy mm dd APPROVED...

Страница 2: ...MERGENCY 8 2 8 WARNING CAUTION AND NOTE STATEMENTS 9 2 9 RF COMPLIANCE FCC USA AND ICES CANADA 9 2 9 1 Unauthorised Changes 9 2 9 2 Radio Interference 9 2 9 3 RF Exposure 10 2 9 4 FCC Class B digital...

Страница 3: ...GGER BATTERY 21 5 1 CHARGING THE DIGISHOT PLUS CE4 TAGGER 21 5 1 1 Low Battery 22 5 2 POWER DIGISHOT PLUS CE4 TAGGER ON AND OFF 23 5 2 1 DigiShot Plus CE4 Tagger Power ON 23 5 2 2 DigiShot Plus CE4 Ta...

Страница 4: ...Configuration 63 10 1 5 Multiple Channel Configuration 64 10 1 6 Select Channel Configuration 65 10 1 7 Use Starter Dets 66 10 2 DEVICE SETUP 67 10 2 1 Contrast 67 10 2 2 Brightness 68 10 2 3 Time Zo...

Страница 5: ...earch 87 11 4 2 High Leakage 88 11 4 3 Leakage through conductive materials 89 12 SPECIFICATIONS 90 12 1 TEMPERATURE LIMITATIONS 90 12 2 BATTERY LIFE 90 12 3 STORING THE DIGISHOT PLUS TAGGER 90 12 4 C...

Страница 6: ...e manufacturer must be followed Training and software upgrades shall only be performed by a DetNet SA subject matter expert Contact the DetNet head office for additional information ALL USERS OPERATIN...

Страница 7: ...CE4 DigiShot Plus CE4 Tagger is Inherently Safe as it cannot produce the necessary minimum required firing voltage to blast the electronic DigiShot Plus detonator In addition the DigiShot Plus CE4 Ta...

Страница 8: ...en glass and to prevent liquid crystal from the screen touching the skin or entering the eyes or mouth Batteries may leak or explode if incorrectly handled Only use batteries approved for use in the D...

Страница 9: ...tion which is always placed in cautions or warnings Refer to http www detnet com for additional detail and documentation DetNet South Africa has not approved any changes or modifications to this devic...

Страница 10: ...io or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or re...

Страница 11: ...the LCD screen a buzzer and a vibration motor to draw the user s attention to the system s current state The DigiShot Plus Tagger is designed for use on the blast front and it is incapable of producin...

Страница 12: ...th Africa Copyright 2019 Harness wire terminals Pogo Pin Connector Blue Status LED White Charge LED Red Error LED LCD Screen Soft Keys Navigation keys yellow arrows Enter key Backspace key Escape key...

Страница 13: ...onments where the temperature drops below 15 C the internal heater pad will automatically switch on to warm the display The Soft Keys will activate functions that appear at the bottom of the LCD scree...

Страница 14: ...es a rechargeable 3 7V Lithium Polymer battery Although the battery has sufficient power to operate the DigiShot Plus CE4 Tagger the operating voltage is significantly lower than the minimum firing vo...

Страница 15: ...ated via the internal GPS The CE4 Tagger version 4 and later is equipped with a Near Field Communication NFC reader located on the rear of the Tagger NFC functionality will be activated in a future so...

Страница 16: ...iShot mode and the keyboard mode It will also indicates when the device is charging if the heater is on or if GPS is available Use the Numerical keys to enter numerical values to select a function fro...

Страница 17: ...eturn a changed numeric input field to the original value Pressing escape will exit the menu Fixed range numeric input may be scrolled if indicated by up down arrows associated with the field Pressing...

Страница 18: ...splayed and this function will not alter the operation of any other menus A quick access information screen is available in all menus Press the key to view system notifications If any and quick info T...

Страница 19: ...Heater Pad can operate with the internal polymer battery independently of the external battery pack and will switch ON when the temperature drops below 15 C External Battery Pack enclosure is attached...

Страница 20: ...trol equipment The Surface harness wire is yellow and green individually sheathed copper wire 0 63mm in diameter DigiShot can be connected in any order to the surface harness as the detonator connecto...

Страница 21: ...er The DigiShot Plus CE4 Tagger will automatically start charging as soon as the USB connector port is plugged into a USB socket A battery level indication will be displayed during charging The tagger...

Страница 22: ...System information screen Detailed in Chapter 9 of this manual to check that the Tagger is being charged Detailed information such as current consumption state of health of the battery and temperatur...

Страница 23: ...ing screen is only displayed when the tagger is plugged into a USB Wireless charger external battery pack or charging source Pressing ESCAPE returns the user to the original screen and prevents this s...

Страница 24: ...E SOFTWARE NOT RESPONDING TO THE KEY IN COMBINATION WITH THE KEY IT IS POSSIBLE TO FORCE THE TAGGER TO POWER OFF BY PRESSING AND HOLDING THE KEY FOR AT LEAST 10 SECONDS TO POWER OFF THE TAGGER NOTE TH...

Страница 25: ...onator list 1 Main Menu Press to select New Design 2 Clear Memory Press Soft Key to clear detonator list Press Soft Key to exit option and return to Main Menu 3 Warning If YES was selected Det List Cl...

Страница 26: ...hole 1 15 OR a Special an out of pattern detonator 1 255 1 Main Menu Press to select Tag Detonators 2 Tag Detonators Warning Press Soft Key to acknowledge warning 3 Tag Side Press Soft Key to tag onl...

Страница 27: ...ica Copyright 2019 This screen will only be displayed if the option to tag on one side only was selected 5 Tag Detonators Use the numerical keypad to enter number of detonators used in each hole Press...

Страница 28: ...e displayed if the option to tag on both sides was selected The Function key may be used to select the required side while in the Tagging mode as follows Press and hold key while pressing the Soft Key...

Страница 29: ...key may be used to select Channels while in the Tagging mode as follows Press and hold key while pressing or key to toggle up or down between Channels Test Single Det While in the Tagging menu the use...

Страница 30: ...e user enters the tagging menu but can also be changed while in the tagging menu Press and hold the key while pressing the or key to adjust this setting A message will display the new Maximum Dets per...

Страница 31: ...o change sides of Initiation Point Press Soft Key to toggle between Left and Right side Tagging left hand side Tagging right hand side The Tagger will display the selected side When tagging ensure the...

Страница 32: ...are assigned later Adding Special detonators Use the Pattern Soft Key to toggle between IN and OUT of pattern holes to add Special detonators Press to adjust the detonator number manually if required...

Страница 33: ...d in any order Row numbers have to be manually changed ROW denotes row number being tagged Press to increase row number Press to decrease row number When tagging ensure the row number is selected acco...

Страница 34: ...oser to the initiation point and higher numbers are further away from the initiation point as with chevron blasting practices HOLE denotes the hole number being tagged Press to increase hole number ma...

Страница 35: ...bel to avoid wrong position tagging Decked DigiShot Plus detonators also need to be clearly marked on the blast plan to ensure their locations are correctly assigned Refer to the Advanced Setup sectio...

Страница 36: ...the hole numbering for each hole At the end of a row the row number and increment decrement may need to be manually adjusted before tagging the next row To change hole increment and decrement Press So...

Страница 37: ...us CE4 Tagger to one end of the Harness wire and untagged detonators are connected one at a time The tagger will automatically tag the location as each detonator is connected The existing tagged deton...

Страница 38: ...ect the channel to test in the test all row menu only if multiple channels are used An option to halt on errors while testing is available and may be configured as Halt on test under the DigiShot Setu...

Страница 39: ...displayed Press Soft Key to continuously repeat test Press Soft Key to stop continuously repeating test The information bar at the bottom of the Tagger screen displays the CURRENT state i e the Soft K...

Страница 40: ...rness wire that are not in the detonator list will be ignored Use Autosearch or Check Pattern to locate newly connected detonators 1 Main Menu Press to select Test Menu 2 Test Menu Connect all detonat...

Страница 41: ...Test all detonators in the row Failed detonators will be displayed Total amount of detonators will be displayed Press Soft Key to continuously repeat test Press Soft Key to stop continuously repeatin...

Страница 42: ...Press to select Test Single Det 3 Test Single Det Tagged location is displayed If the Detonator contains a wire length this value is displayed This value is displayed in meters and feet Press Soft Key...

Страница 43: ...In multi channel mode only the detonators in the selected channel will be erased 1 Main Menu Press to select Test Menu 2 Test Menu Ensure that the detonator is connected to the Tagger Press to select...

Страница 44: ...er the Last row number on which the search will end Press to continue Use numerical keys to enter maximum detonators per hole to search for Press to continue Use numerical keys to enter maximum specia...

Страница 45: ...e in the same hole or move to a new hole a new side or a new row To ensure that the search is performed as rapidly as possible it will proceed to a new hole side or row after a selected number of bad...

Страница 46: ...t in blasting problems This should be addressed and the leakage problem resolved Leakage higher than 1mA is considered high leakage and will likely result in blasting problems potential misfires and s...

Страница 47: ...Test Menu 2 Test Menu Press to select Untagged Test 3 Untagged Test OK message displayed when no untagged detonators are found Error message displayed when untagged detonators are found While performi...

Страница 48: ...Pattern generates a list of Missing detonators that were not found when compared to the detonator list Check Pattern generates a list of new detonators found during test which were not part of the ori...

Страница 49: ...om the first row specified to the last row specified and the maximum number of special detonators in the list or as found taking bad holes detonators into account 6 Check Pattern After Check Pattern f...

Страница 50: ...e This function enables the user to scroll to the next or previous page Press the Soft Key to scroll to the next and the Soft Key to scroll to the previous page Sort Mode Press the Soft Key to sort by...

Страница 51: ...est Single Det In the Detlist View menu the user has the option to test a single detonator Connected to the pogo pin connector by pressing the minus power key During this test any detonators connected...

Страница 52: ...ain Menu Press to select View Design 2 View Design Menu Press to select List Detonators 3 List Detonators The List Detonators screen will be displayed Use Soft Keys to navigate pages and sort filter t...

Страница 53: ...screen lists the DigiShot Plus detonators that were not found during the Check pattern test or test all 1 Main Menu Press to select View Design 2 View Design Menu Press to select List Missing Dets 3 L...

Страница 54: ...es not overwrite the detonator list 1 Main Menu Press to select View Design 2 View Design Menu Press to select List New Dets 3 List New Dets The List New Detonators screen will be displayed Use Soft K...

Страница 55: ...rn test A bad status indicates the detonator may have a bad fuse or other internal problem 1 Main Menu Press to select View Design 2 View Design Menu Press to select List Bad Status 3 List Bad Status...

Страница 56: ...Blast Summary The Blast Summary screen displays the Rows in the first column The number of detonators holes on the Left and Right side per corresponding row is displayed The total number of Special de...

Страница 57: ...have been found The list also includes any missing detonators 1 Main Menu Press to select View Design 2 View Design Menu Press to select Det Totals 3 Det Totals The Det Totals screen will display a s...

Страница 58: ...a negative value indicates that current is being drawn from the battery Cell Status Good indicates the state of health of the battery Should the status indicate Low the unit should be serviced to have...

Страница 59: ...ocation will be displayed Altitude and the number of satellites found will also be displayed 6 System Info User ID Press to select page right Press to enter or edit User ID Use alphanumeric characters...

Страница 60: ...e before the search progresses to the following hole Press to continue Use numerical keys to enter Maximum consecutive missing holes on a row before the search progresses to the alternate side or the...

Страница 61: ...on 2 Configuration Menu Press to select DigiShot Setup 3 DigiShot Setup Press to select Autotag 4 Autotag Press to enable disable Autotag Press Soft Key to save Press Soft Key to return to Main Menu W...

Страница 62: ...on bar displays side leakage and the signal strength of the detonator reply 1 Main Menu Press to select Configuration 2 Configuration Menu Press to select DigiShot Setup 3 DigiShot Setup Press to sele...

Страница 63: ...during testing 1 Main Menu Press to select Configuration 2 Configuration Menu Press to select DigiShot Setup 3 DigiShot Setup Press to select Halt on test 4 Halt on test Press to select Halt on test...

Страница 64: ...tonators spread across 6 channels 1 Main Menu Press to select Configuration 2 Configuration Menu Press to select DigiShot Setup 3 DigiShot Setup Press to select Multiple Channel 5 Multiple Channel Pre...

Страница 65: ...ted During tagging however the software will check the entire list across all channels for location exists errors to avoid duplicate detonators 1 Main Menu Press to select Configuration 2 Configuratio...

Страница 66: ...elect Configuration 2 Configuration Menu Press to select DigiShot Setup 3 DigiShot Setup Press to select Use Starter dets 4 Use Starter Dets Use the arrow key to display the YES NO option as required...

Страница 67: ...ation Menu Press to select Device Setup 3 Device Setup Press to select Contrast 4 Contrast Use the arrow key to adjust contrast Adjust to ensure the displayed contrast blocks are distinguishable to al...

Страница 68: ...ser to adjust the LCD screen brightness 1 Main Menu Press to select Configuration 2 Configuration Menu Press to select Device Setup 3 Device Setup Press to select Brightness 4 Adjusting the Brightness...

Страница 69: ...me zone cannot be configured automatically it should always be set by the user in order to ensure the correct local time display 1 Main Menu Press to select Configuration 2 Configuration Menu Press to...

Страница 70: ...o conserve battery power The user can set the idle time between 2 and 120 minutes 1 Main Menu Press to select Configuration 2 Configuration Menu Press to select Device Setup 3 Device Setup Press to se...

Страница 71: ...igiShot Plus Tagger menus 1 Main Menu Press to select Configuration 2 Configuration Menu Press to select Device Setup 3 Device Setup Press to select Language 4 Language Press on the keypad to select E...

Страница 72: ...elect Advanced Setup Use numerical keypad to enter Unique Tagger Password Press ENTER to continue 3 Advanced Setup Press to select Tagger ID 4 Tagger ID Using numerical keypad to enter Unique Tagger I...

Страница 73: ...vanced Setup Use numerical keypad to enter Unique Tagger Password Press ENTER to continue 3 Advanced Setup Press to select Clear Tags 4 Clear Tags An information screen will be displayed Press Soft Ke...

Страница 74: ...d from unauthorised use by assigning a password 1 Main Menu Press to select Configuration Settings 2 Configuration Settings Menu Press to select Advanced Setup Use numerical keypad to enter Unique Tag...

Страница 75: ...Passwords Use the numerical keypad to enter New Password Press to confirm 7 Passwords Information message confirming password changed will be displayed briefly Tagger will display Password Screen Pres...

Страница 76: ...Configuration Settings Menu Press to select Advanced Setup Use numerical keypad to enter Unique Tagger Password Press ENTER to continue 3 Advanced Setup Press to select Hole Load Mode 4 Hole Load Mode...

Страница 77: ...onfiguration Settings Menu Press to select Advanced Setup Use numerical keypad to enter Unique Tagger Password Press ENTER to continue 3 Advanced Setup Press to select DigiShot Mode 4 DigiShot Mode Pr...

Страница 78: ...numerical keypad to enter Unique Tagger Password Press ENTER to continue 3 Advanced Setup Press to select Storage Mode 4 Storage Mode When the battery capacity is more than 50 the tagger will discharg...

Страница 79: ...to logs 1 Main Menu Press to select Configuration Settings 2 Configuration Settings Menu Press to select Advanced Setup Use numerical keypad to enter Unique Tagger Password Press ENTER to continue 3...

Страница 80: ...e Tagger Password Press ENTER to continue 3 Advanced Setup Leave Tagger in Advanced menu and open the PC software to connect Remote View This function enables the user to demonstrate the Tagger in act...

Страница 81: ...ESC to abort tagging While the tagger waits for user input other key presses are ignored as the user must respond to the indicated problem with ENTER or ESCAPE On completion of the tagging process a m...

Страница 82: ...Location exists The chosen location already exists in the detonator list Manually adjust location according to blast plan if required Tagger vibrates to inform the user of an error condition Press to...

Страница 83: ...status indicates the detonator may have a bad fuse or other internal problems Tagger vibrates to inform the user of an error condition Press to retag with the new location or ESC to abort tagging Lab...

Страница 84: ...message will be displayed indicating High leakage and or Untagged Dets Found The untagged test is also integrated into Test All Test Row Check Pattern and Autosearch but there it elicits a custom erro...

Страница 85: ...Status Dets Detonators in the design has tested with a bad status Bad status indicates the detonator may have a bad fuse or other internal problems Replace the detonator to avoid a possible misfire Fa...

Страница 86: ...s not correctly de sludged rubbing of down hole line against hole wall bent cable when lowering booster into a hole Detonator cable damaged around the insulation exposing the steel wire Ingress of wat...

Страница 87: ...he search area 6 By repeating this process the fault is narrowed down to a small and manageable area At this point DigiShot Plus detonators may be disconnected from the surface harness and tested one...

Страница 88: ...us Tagger display high leakage it indicates a fault present 3 Connect DigiShot Plus Tagger and check front half for leakage Should the DigiShot Plus Tagger display satisfactory leakage it indicates no...

Страница 89: ...Plus Tagger and check the rear half of the installation for leakage Tagger displays satisfactory leakage Connect DigiShot Plus Tagger and check front half of the installation for leakage Tagger displ...

Страница 90: ...the DigiShot Plus Tagger body wipe gently using a soft dry cloth Dust on the screen should be blown off before gently wiping with a soft dry cloth so as to avoid scratches Ensure the Pogo pin connecto...

Страница 91: ...vent ingress of moisture or condensation into the battery pack enclosure Do not apply undue pressure to the LCD screen as this could damage the Tagger or cause a malfunction Should the LCD screen brea...

Отзывы: