background image

Access Control LCD Keypad V1.0

DGP-641ACC

Programming Guide

P

ROGRAMMING

 M

ETHOD

 

To view the keypad’s serial number, press and hold the 

[0]

 key,

then enter the

 [

INSTALLER

 

CODE

]

 and enter 

[000]

. We recommend

that you use this sheet to keep track of which sections were
programmed and how. This module can also be programmed using
the control panel’s Broadcast Programming Feature (see 

Digiplex

Installation & Reference Manual

).

P

ROGRAMMING

 S

ECTIONS

In the following tables and sections, any value represented in 

bold

is the default setting.

SECTION [006]

 

“Door Unlocked Period” (001-255 seconds)
___/___/___ (default = 005)

SECTION [007]

 

“Door Unlocked Period Extension” (001-255 seconds added to [007])
___/___/___ (default = 015)

SECTION [008]

 

“Door Left Open” Interval (001-255 seconds)
___/___/___ (default = 060)

SECTION [009]

 

“Door Left Open” Pre-Alarm Timer (001-255 seconds)

Time to start Pre-Alarm before alarm is triggered.

___/___/___ (default = 015)

SECTION [010]

 

Beep Timer for “Door Left Open” Alarm (001-255 seconds)

Amount of time “Door Left Open” alarm will beep.

___/___/___ (default = 005)

SECTION [011]

 

Beep Timer for “Door Forced Open” Alarm (001-255 seconds)

Amount of time “Door Forced Open” alarm will beep.

___/___/___ (default = 005)

STEP 1: Press and hold the 

[0]

 key

STEP 2: Enter the 

[

INSTALLER

 

CODE

]

 

STEP 3: Enter section 

[953]

 

STEP 4: Enter the keypad’s 8-digit 

[

SERIAL

 

NUMBER

]

STEP 5: Enter the 3-digit 

[

SECTION

]

 you want to program

STEP 6: Enter the required data

SECTION [001]: Partitioning

Option

OFF

ON

[1]

Partition 1

 l

 Disabled

 l

 

Enabled

[2]

Partition 2

 l

 Disabled

 l

 

Enabled

[3]

Partition 3

 l

 Disabled

 l

 

Enabled

[4]

Partition 4

 l

 Disabled

 l

 

Enabled

[5]

Assign Door to Partition 1

 l

 Disabled

 l

 

Enabled

[6]

Assign Door to Partition 2

 l

 

Disabled

 l

 Enabled

[7]

Assign Door to Partition 3

 l

 

Disabled

 l

 Enabled

[8]

Assign Door to Partition 4

 l

 

Disabled

 l

 Enabled

SECTION [002]: General Options

Option

OFF

ON

[1]

Display Code Entry

 l

 

Disabled

 l

 Enabled

[2]

Display Exit Delay

 l

 

Disabled

 l

 Enabled

[3]

Display Entry Delay

 l

 

Disabled

 l

 Enabled

[4]

Confidential Mode 
(not for UL installations)

 l

 

Disabled

 l

 Enabled

[5]

To Exit Confidential Mode

 l

 

Enter Code

 l

 Press Button

[6]

Reader’s red LED  to follow 
Partition’s status

 l

 Disabled

 l

 

Enabled

[7]

Reader’s beeping  to follow 
Partition’s status when [6] ON

 l

 Disabled

 l

 

Enabled

[8]

Not used

 l

 N/A

 l

 N/A

SECTION [003]: General Options

Option

OFF

ON

[1]

Muting

 l

 

Disabled

 l

 Enabled

[2]

Exit Delay Beep

 l

 Disabled

 l

 

Enabled

[3]

“Door Left Open” Pre-Alarm

 l

 Disabled

 l

 

Enabled

[4]

Chimed Zone Closure

 l

 

Disabled

 l

 Enabled

[5]

“Door Left Open” Alarm

 l

 Silent

 l

 

Audible

[6]

“Door Left Open” Alarm follows

 l

 

Alarm Restore

 l

 Beep Timer

[7]

“Door Forced” Alarm

 l

 Silent

 l

 

Audible

[8]

“Door Forced” Alarm follows

 l

 

Alarm Restore

 l

 Beep Timer

SECTION [004]: Beep on Trouble

Option

OFF

ON

[1]

System & Clock Trouble Beep

 l

 

Disabled

 l

 Enabled

[2]

Communicator Trouble Beep

 l

 

Disabled

 l

 Enabled

[3]

Module & Bus Trouble Beep

 l

 

Disabled

 l

 Enabled

[4]

All Zone Trouble Beeps

 l

 

Disabled

 l

 Enabled

[5] to [8]

Not used

 l

 N/A

 l

 N/A

SECTION [005]: 

General Options

Option

OFF

ON

[1]

Card Activates Door 
Unlocked Schedule

 l

 Disabled

 l

 

Enabled

[2]

Not used

 l

 N/A

 l

 N/A

[3]

Not used

 l

 N/A

 l

 N/A

[4]

Not used

 l

 N/A

 l

 N/A

[5]

Keypad Tamper

 l

 

Disabled

 l

 Enabled

[6]

Door will Relock

 l

 

Immediately

 l

 When closed

[7]

Reader’s Green LED for 
Access Granted

 l

 Disabled

 l

 

Enabled

[8]

Door Handle Option for REX

 l

 

Turn Handle

 l

 Push Open

SECTION [012]: Door Unlocked Schedule

Start time

End time

Days 

(turn 

ON

 or 

OFF

)

S M T W T F S H

A:

___ ___:___ ___ ___ ___:___ ___ 1 2

3 4

5 6 7

8

B:

___ ___:___ ___ ___ ___:___ ___ 1 2

3 4

5 6 7

8

Отзывы: