INTRODUCTION 

L dimmers, timers, switches and occupancy sensors include MultiMate

 technology. These 

devices have revolutionised multiple point control of lighting whilst using conventional wiring practices.  

Even when not used for multi-way control, their superior compatibility with LED lighting loads makes them 
the best wall plate lighting controls in the market. 

 

MULTIMATE™ TECHNOLOGY

 

MultiMate™ is 

the technology inside the 

range of high quality L dimmers, 
timers, switches and occupancy sensors. It 
allows multi-way control of lighting loads 
without the need for an expensive control 
system. M

ultiMate™ technology is suitable 

for both new and retrofit installations. 

MultiMate™ technology enables multiple 

L two-wire devices to be wired in 
parallel when two-way, three-way or 
multi-way dimming and switching is 
required. 

When connected in parallel, L 
dimmers, timers, switches and occupancy 
sensors allow dimming and switching of 
connected lighting loads from multiple locations without any additional wiring. No strapper wires, 
dedicated remote switch wiring or control bus is required. 

HOW MULTIMATE

 WORKS 

MultiMate

 products use a patented method of communicating with each other using the mains wiring. By 

this means dimmers, timers, switches and occupancy sensors can communicate on/off, level, and settings 
to other L products on the same circuit. 

INSTALLATION 

In normal cases, existing switches can be removed and replaced by MultiMate

 dimmers, timers, switches 

and occupancy sensors. Please refer to the installation instructions for common wiring methods used for 1-
way, 2-way, 3-way and other configurations. 

TROUBLESHOOTING 

Like all products, sometimes there can be problems caused by the electrical behaviour of the building 
wiring, or that of the lighting loads. This document describes some cases found from real-world product 
experience and their solutions. 

Each of the following pages describes a problem and solution. In some case additional product(s) may be 
required. 

APPLICABLE PRODUCTS 

Dimmers: 

 

MMDM/PB & MMDM/RT 

Timers:  

 

MMTM/PB & MMTH/PB 

Switches: 

 

MMSW/PB 

Occupancy Sensors: 

MMSE/PR 

 

 

Neutr

al

Neutr

al

Active

Active

Load

Load

Load

Active

Act

ive

Neu

tral

Содержание LEDsmart+ MultiMate MMTM/PB

Страница 1: ...Setup Functions Guide MMTM PB www glg lighting Push Button Minute Timer Programmable between 1 minute and 30 minutes with built in multi way control...

Страница 2: ...mer Setup Functions Function See Part Setting the Timeout period A Setting Maximum Brightness B Setting Advanced Timer Features C Setting Off State LED Feature D Converting from minute to hour timer E...

Страница 3: ...o be adjusted as required Go to the relevant setup function instructions A2 Timer has been powered up via mains 240Vac for MORE THAN 15 MINUTES Step 1 Press and hold the button for 30 seconds Note Thi...

Страница 4: ...othing for 30 seconds Step 4 To set the time out interval push and hold the button and count the number of blinks Each blink of the indicator adds 1 minute to the minute timer Step 5 When the number o...

Страница 5: ...ep 1 Enter into the timer Setup Mode See PART A Step 2 Click the push button 3 times Step 3 The LED Indicator will blink 3 times Note To cancel exit do nothing for 30 seconds Note If more than one dim...

Страница 6: ...tep 2 Click the push button 4 times Step 3 The LED Indicator will blink 4 times Note To cancel exit do nothing for 30 seconds Step 4 To enable the advanced timer mode Push and hold the button until th...

Страница 7: ...n the timer is off follow the steps below Step 1 Enter into the timer Setup Mode See PART A Step 2 Click the push button 5 times Step 3 The LED Indicator will blink 5 times Note To cancel exit do noth...

Страница 8: ...Enter into the timer Setup Mode See PART A Step 2 Click the push button 6 times Step 3 The LED Indicator will blink 6 times Note To cancel exit do nothing for 30 seconds Step 4 To change operation to...

Страница 9: ...s connected to the dimmer will now turn OFF b If the MultiMate function is currently Enabled lamps s connected to the dimmer will now turn ON Note To cancel exit do nothing for 30 seconds Step 4 To En...

Страница 10: ...Button Minute Timer 10 H Resetting to Factory Default Step 1 Enter into the timer Setup Mode See PART A Step 2 Click the push button 10 times Step 3 The timer will automatically exit Setup Mode once r...

Страница 11: ...ment to Gerard Lighting Gerard Lighting Pty Ltd Gerard Lighting reserves the right to alter the specifications designs or other features of any items and to discontinue any items at any time without n...

Страница 12: ...hing of connected lighting loads from multiple locations without any additional wiring No strapper wires dedicated remote switch wiring or control bus is required HOW MULTIMATE WORKS MultiMate product...

Страница 13: ...higher value Refer to the product installation guide for details Solution 2 Fit a load bypass device order code MMBP Solution 3 In extreme cases both the MMBP and a raised minimum level may be needed...

Страница 14: ...own transformer to building High resistance terminations on active feeds and or neutral returns and Neutral returns from a common active feed having significantly different run lengths back to the swi...

Страница 15: ...mable LED load may be used on the same circuit as non dimmable loads In this case when the dimmer level is higher than a threshold the relay is operated to switch the non dimmable load s on and the di...

Отзывы: