12
Ultra Resolution TDN WDR Varifocal IR Vandal Dome
13
Ultra Resolution TDN WDR Varifocal IR Vandal Dome
■
Installation
1. Dome Base Mounting
- Open the dome cover by loosening 3 screws using special wrench
provided.
- Mount the base of camera to a sturdy surface using 4 screws
(1.5 inch) and 4 premade holes on the base of the dome.
2. Power Connect & Monitor Impedance
- DC12V/300mA regulated power supply (DC12V only)
AC24V Class 2 power supply (AC24V/DC12V)
- To avoid fire or shock hazard, must use a UL listed power supply.
- Set the monitor impedance switch to 75
Ω
. Check the impedance
switch when the screen turns blurred.
3. Camera Module Adjustment
- Loosen screws for the 3-axis camera bracket to adjust the cameras
angle of view.
- Make sure to retighten the camera bracket screws.
- Use the OSD buttons to select the different camera functions.
4. Dome Cover Mounting
- Replace the dome cover to the base and tighten the 3 screws.
Control via RS-485 Interface (Optional)
RS-485 Control Port
485 Control Board Connection Port
485+
(+) CONNECTION TERMINAL (TRX+)
(- ) CONNECTION TERMINAL (TRX-)
485-
Item
Initial value
PET PKT
UART MODE
BAUD RATE
Camera ID
ENABLE
8-NONE-1
2400
1
The camera can be controlled by using an external controller equipped
with RS-485 communications.
• To control using a DVR or keyboard controller
Connect the RS-485 cable (TRX+, TRX-) to the connection port of the
485 control board in the DVR or controller.
* RS-485 communication default initial values
• To control the camera use Pelco-D protocol.
- Set Preset 95 : Enters into OSD menu.
- Iris Open command : Set key function.
- Iris Close command : Cancel function.
Note
■
Cable Connections
DC only
AC24V
DC12V
AC IN
DC IN
AC IN
DC IN
VIDEO
POWER
RS-485(Optional)
LENS MASK
CONDUIT
PLUG
No. 8-32
UNC
DECORATION
RING
M4*10
CAMERA
BASE
RUBBER
BOTTOM